Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Radiat Oncol Biol Phys ; 48(2): 501-5, 2000 Sep 01.
Article in English | MEDLINE | ID: mdl-10974468

ABSTRACT

BACKGROUND: This study is to report the clinical experiences of fractionated stereotactic radiation therapy (FSRT) for extracranial head and neck tumors. METHODS AND MATERIALS: Between the period of July 1995 and November 1998, 48 patients with extracranial head and neck tumors were given FSRT as a boost and sole modality. Individualized treatment planning was performed using XKnife-3 system with relocatable Gill-Thomas-Cosman frame. In 24 patients, FSRT was applied as a boost technique following the 2-dimensional conventional external radiation therapy (ERT); in 24 patients FSRT was the sole radiotherapy modality. The primary diseases in the boost group consisted of nasopharynx cancer (19), lacrimal gland adenoid cystic carcinoma (3), orbital lymphoma (1), and skull-base recurrence of maxillary sinus adenoid cystic carcinoma (1). The primary diseases in the sole modality group consisted of recurrent nasopharynx cancer (12), orbital pseudotumor (4), skull-base recurrence of maxillary sinus, submandibular gland, and hypopharynx cancers (3), orbital rhabdomyosarcoma (2), orbital lymphoma (1), orbital metastasis of neuroblastoma (1), and nasal cavity melanoma (1). The fractionation schedule was to give 5 treatments per one week and the fractional doses were 2.0-3 Gy depending on the treatment aim and the FSRT volume. The FSRT doses varied depending on the nature of the primary diseases. RESULTS: The local tumor response in nasopharynx cancer patients was excellent compared to retrospective data without occurrence of unexpectedly severe complication. FSRT to other regions was well tolerated by the patients and resulted in good to excellent local tumor responses with no unacceptable side effects as expected by the authors. CONCLUSION: Based on the current observations, FSRT is a very effective and safe modality in the treatment of extracranial head and neck tumors.


Subject(s)
Head and Neck Neoplasms/surgery , Radiosurgery/methods , Carcinoma, Adenoid Cystic/diagnostic imaging , Carcinoma, Adenoid Cystic/surgery , Dose Fractionation, Radiation , Follow-Up Studies , Head and Neck Neoplasms/diagnostic imaging , Humans , Lacrimal Apparatus Diseases/diagnostic imaging , Lacrimal Apparatus Diseases/surgery , Lymphoma/diagnostic imaging , Lymphoma/surgery , Nasopharyngeal Neoplasms/diagnostic imaging , Nasopharyngeal Neoplasms/surgery , Orbital Neoplasms/diagnostic imaging , Orbital Neoplasms/surgery , Radiotherapy Planning, Computer-Assisted , Skull Base Neoplasms/diagnostic imaging , Skull Base Neoplasms/secondary , Skull Base Neoplasms/surgery , Survival Analysis , Tomography, X-Ray Computed
2.
Int J Radiat Oncol Biol Phys ; 48(2): 541-4, 2000 Sep 01.
Article in English | MEDLINE | ID: mdl-10974474

ABSTRACT

PURPOSE: A new collimator cone system has been developed at the Samsung Medical Center that overcomes some of the limitations of present commercially supplied collimator cones. The physical properties of the newly developed cone system are described in this report. METHODS AND MATERIALS: The new cones have relatively larger aperture sizes (3.0-7.0 cm in diameter) and are 16 cm in length. Each new cone is fabricated with cerrobend alloy melted and poured into a stainless steel housing that is permanently fixed to a mounting plate. The mounting plate of the new cone is designed to insert into the wedge mount slot of the gantry head. The mechanical accuracy of the central axis of the cone pointing to the isocenter was tested using film, a steel ball positioned at the isocenter by the mechanical isocenter device. For the evaluation of beam flatness and penumbra, off-axis ratios at 5 cm depth were measured by film dosimetry using polystyrene phantom. RESULTS: The average error of the mechanical isocenter was 0.27 mm (+/- 0.16 mm). The beam flatness was excellent in the central region of the beam, and the average penumbra width was 3.35 mm (+/- 0.25 mm). The new cone design has more clearance between the patient's head and the gantry, and can more easily be removed from the gantry head because it slides in and out of the wedge slot. This facilitates changing cone sizes during one treatment session, and makes the process of double exposure port films easier. CONCLUSIONS: A new collimator cone system for stereotactic radiation therapy has been developed. The mechanical accuracy and physical properties are satisfactory for clinical use, and the new design permits a wider range of clinical applications for stereotactic radiation therapy.


Subject(s)
Radiosurgery/instrumentation , Alloys , Equipment Design , Evaluation Studies as Topic , Health Physics
3.
J Food Prot ; 63(12): 1707-12, 2000 Dec.
Article in English | MEDLINE | ID: mdl-11131895

ABSTRACT

Strain BH5 was isolated from naturally fermented Kimchi and identified as a bacteriocin producer that has bactericidal activity against Micrococcus flavus ATCC 10240. Strain BH5 was identified tentatively as Lactococcus lactis by API test. Lactococcus lactis BH5 showed a broad spectrum of activity against most of the nonpathogenic and pathogenic microorganisms tested by the modified deferred method. The activity of lacticin BH5, named tentatively as the bacteriocin produced by L. lactis BH5, was detected at the mid-log growth phase, reached its maximum during the early stationary phase, and decreased after the late stationary phase. Lacticin BH5 also showed a relatively broad spectrum of activity against nonpathogenic and pathogenic microorganisms as tested by the spot-on-lawn method. Its antimicrobial activity on sensitive indicator cells was completely destroyed by protease XIV. The inhibitory activities of lacticin BH5 were detected during treatments up to 100 degrees C for 30 min. Lacticin BH5 was very stable over a pH range of 2.0 to 9.0 and was stable with all the organic solvents examined. It demonstrated a typical bactericidal mode of inhibition against M. flavus ATCC 10240. The apparent molecular mass of lacticin BH5 was estimated to be in the region of 3 to 3.5 kDa, by the direct detection of bactericidal activity after sodium dodecyl sulfate-polyacrylamide gel electrophoresis.


Subject(s)
Bacterial Proteins/isolation & purification , Bacteriocins/isolation & purification , Lactococcus lactis/metabolism , Bacterial Proteins/biosynthesis , Bacterial Proteins/pharmacology , Bacteriocins/biosynthesis , Bacteriocins/pharmacology , Brassica/microbiology , Electrophoresis, Polyacrylamide Gel , Fermentation , Food Microbiology , Food Preservation , Hot Temperature , Hydrogen-Ion Concentration , Lactococcus lactis/classification , Microscopy, Electron, Scanning , Molecular Weight , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...