Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Korean J Radiol ; 15(4): 456-63, 2014.
Article in English | MEDLINE | ID: mdl-25053905

ABSTRACT

OBJECTIVE: To evaluate the prevalence of known risk factors for contrast-induced nephropathy (CIN) and their association with the actual occurrence of CIN in patients undergoing intravenous contrast-enhanced computed tomography (CECT) in Korea. MATERIALS AND METHODS: Patients who underwent CECT in 2008 were identified in the electronic medical records of 16 tertiary hospitals of Korea. Data on demographics, comorbidities, prescriptions and laboratory test results of patients were collected following a standard data extraction protocol. The baseline renal function was assessed using the estimated glomerular filtration rate (eGFR). We identified the prevalence of risk factors along the eGFR strata and evaluated their influence on the incidence of CIN, defined as a 0.5 mg/dL or 25% increase in serum creatinine after CECT. RESULTS: Of 432425 CECT examinations in 272136 patients, 140838 examinations in 101487 patients met the eligibility criteria for analysis. The mean age of the participants was 57.9 ± 15.5 years; 25.1% of the patients were older than 70 years. The prevalence of diabetes mellitus was 11.9%, of hypertension 13.7%, of gout 0.55% and of heart failure was 1.7%. Preventive measures were used in 40238 CECT examinations (28.6%). The prevalence of risk factors and use of preventive measures increased as the renal function became worse. A CIN was occurred after 3103 (2.2%) CECT examinations, revealing a significant association with decreased eGFR, diabetes mellitus, and congestive heart failure after adjustment. CONCLUSION: Risk factors for CIN are prevalent among the patients undergoing CECT. Preventive measures were seemingly underutilized and a system is needed to improve preventive care.


Subject(s)
Contrast Media/adverse effects , Kidney Diseases/chemically induced , Kidney Diseases/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Comorbidity , Female , Glomerular Filtration Rate , Humans , Incidence , Kidney Diseases/epidemiology , Male , Middle Aged , Prevalence , Republic of Korea/epidemiology , Risk Factors
2.
Biomaterials ; 34(35): 8918-24, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23958028

ABSTRACT

We present a new class of ultrasound molecular imaging agents that extend upon the design of micromotors that are designed to move through fluids by catalyzing hydrogen peroxide (H2O2) and propelling forward by escaping oxygen microbubbles. Micromotor converters require 62 mm of H2O2 to move - 1000-fold higher than is expected in vivo. Here, we aim to prove that ultrasound can detect the expelled microbubbles, to determine the minimum H2O2 concentration needed for microbubble detection, explore alternate designs to detect the H2O2 produced by activated neutrophils and perform preliminary in vivo testing. Oxygen microbubbles were detected by ultrasound at 2.5 mm H2O2. Best results were achieved with a 400-500 nm spherical design with alternating surface coatings of catalase and PSS over a silica core. The lowest detection limit of 10-100 µm was achieved when assays were done in plasma. Using this design, we detected the H2O2 produced by freshly isolated PMA-activated neutrophils allowing their distinction from naïve neutrophils. Finally, we were also able to show that direct injection of these nanospheres into an abscess in vivo enhanced ultrasound signal only when they contained catalase, and only when injected into an abscess, likely because of the elevated levels of H2O2 produced by inflammatory mediators.


Subject(s)
Hydrogen Peroxide/analysis , Molecular Imaging/methods , Ultrasonics/instrumentation , Animals , Catalase/chemistry , Hydrogen-Ion Concentration , Microbubbles , Microscopy, Electron, Scanning , Nanospheres/chemistry , Neutrophils/chemistry , Neutrophils/cytology , Rats , Rats, Sprague-Dawley , Ultrasonics/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...