Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Zhonghua Yan Ke Za Zhi ; 60(7): 580-591, 2024 Jul 11.
Article in Chinese | MEDLINE | ID: mdl-38955760

ABSTRACT

Objective: To observe the impact of implantable Collamer lens (ICL) implantation surgery on choroidal thickness and blood flow density in myopic patients. Methods: This was a prospective cohort study. Patients undergoing ICL surgery at Qingdao University Affiliated Hospital between June 2021 and May 2023 were consecutively enrolled. Patients were categorized into high myopia (HM) and super high myopia (SHM) groups based on whether their spherical equivalence power exceeded 10.00 D. Comprehensive ophthalmic examinations, including optical coherence tomography, optical coherence tomography angiography, visual acuity assessment, intraocular pressure measurement, and optometry, were performed preoperatively and at 1 week, 1 month, and 3 months postoperatively. Results: A total of 42 patients (84 eyes), with an average age of (25.27±3.18) years, comprising 11 males and 31 females, were enrolled in the study. Among them, 20 patients belonged to the HM group, while 22 patients were in the SHM group. Both choroidal thickness and blood flow density exhibited significant increases at postoperative 1 week and 1 month compared to preoperative levels (P<0.05), but returned to baseline levels by postoperative 3 months. Specifically, the subfoveal choroidal thickness increased from (169.49±61.57) µm preoperatively to (180.16±66.61) µm at 1 week, (186.69±63.32) µm at 1 month, and then reverted to (169.58±60.82) µm at 3 months. The central choroidal blood flow density showed changes from 60.03%±1.60% preoperatively to 61.04%±1.17% at 1 week, 60.42%±1.81% at 1 month, and 60.22%±1.57% at 3 months. Furthermore, the HM group exhibited more pronounced changes in both choroidal thickness and blood flow density across all time points compared to the SHM group. Significant differences were observed in choroidal thickness changes at various areas at 1 month, while changes in blood flow density in specific areas were significant. However, no significant differences were noted at 3 months postoperatively. Correlation analysis revealed a negative correlation of changes in subfoveal choroidal thickness and central choroidal blood flow density postoperatively at 1 week and 3 months with preoperative choroidal blood flow density. Notably, no correlation was found between preoperative choroidal thickness and postoperative changes. Conclusions: In the early period following ICL implantation, the increase in choroidal thickness and blood flow density may be more pronounced in HM compared to SHM, but the two parameters can return to baseline levels by 3 months. ICL implantation transiently affects the fundus microenvironment in myopic patients, with implications of preoperative choroidal blood flow.


Subject(s)
Choroid , Lens Implantation, Intraocular , Myopia , Humans , Choroid/blood supply , Female , Male , Prospective Studies , Adult , Myopia/surgery , Lens Implantation, Intraocular/methods , Phakic Intraocular Lenses , Young Adult
2.
Zhonghua Yan Ke Za Zhi ; 58(8): 615-623, 2022 Aug 11.
Article in Chinese | MEDLINE | ID: mdl-35959606

ABSTRACT

Objective: To investigate the impact of the iris and ciliary body morphology on the central vault after phakic posterior chamber intraocular lens (pIOL) implantation. Methods: This research was based on the retrospective analysis of 123 patients (123 eyes) who underwent pIOL implantation in the Department of Ophthalmology, Affiliated Hospital of Qingdao University between June 2018 and June 2020. The anterior segment structure was observed with an ultrasound biomicroscope before surgery, and all morphological parameters of the iris and ciliary body were measured manually using the ImageJ software, including iris span (IS), iris convexity (IC), iris-ciliary body contact distance (ICCD) and iris-lens contact distance (ILCD). The ICCD was divided into Q1, Q2 and Q3 groups according to the equidistant distance of 0.36 mm. The lens thickness was measured with the IOLMaster. The horizontal corneal diameter and anterior chamber depth were measured using the Pentacam. The central vaults were measured by optical coherence tomography at 1 week, 3 months and 1 year after surgery. The relationships between vault values and preoperative parameters of the anterior segment were evaluated using the Pearson correlation analysis, Spearman correlation analysis, and multiple linear regression. The repeated measures ANOVA was applied to identify changes of vault values over time. Results: The mean values of the vaults at 1 week, 3 months and 1 year after surgery were (723±265) µm, (642±255) µm and (613±280) µm, respectively. The difference among them was statistically significant (F=50.143, P<0.001). The vaults continued to decline within 1 year after pIOL implantation, and the total decline was (122±86) µm. The vaults declined by (69±98) µm from postoperative 1 week to 3 months and by (52±54) µm from postoperative 3 months to 1 year. The regression formula showed that the pIOL size and ILCD were positively related with the vault, while the LT, IS and IC were negatively related with the vault at 1 week postoperatively (adjusted R²=0.404, P<0.001). The pIOL size and ILCD were positively related with the vault, while the IS and IC were negatively related with the vault at 3 months postoperatively (adjusted R²=0.342, P<0.001). The pIOL size was positively related with the vault, while the IS and IC were negatively related with the vault at 1 year postoperatively (adjusted R²=0.661, P<0.001). The vault values were higher in group Q3 compared to group Q1 at every timepoint, and the vault value was higher in group Q2 compared to Q1 at 1 year postoperatively. Conclusions: In the early postoperative period, eyes with a larger pIOL, shorter iris span, longer contact distance between the iris and ciliary body, and longer contact distance between the iris and lens were associated with a higher rate of excessive vaults. Meanwhile, eyes with a thicker lens and larger iris reverse convexity were more likely to obtain insufficient vaults. Within one year after surgery, the pIOL size, IS, IC and ICCD continued to impact on the vault. The ICCD, ILCD and IC can reflect the posterior chamber volume and change the haptic location and force, thus affecting the vault.


Subject(s)
Myopia , Phakic Intraocular Lenses , Ciliary Body , Humans , Iris , Lens Implantation, Intraocular , Myopia/surgery , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...