1.
Int J Dent ; 2015: 294670, 2015.
Article in English | MEDLINE | ID: mdl-25861272

ABSTRACT

Objective. To find out the success rate of miniscrew implants in the National Dental Centre of Singapore (NDCS) and the impact of patient-related, location-related, and miniscrew implant-related factors. Materials and Methods. Two hundred and eighty-five orthodontic miniscrew implants were examined from NDCS patient records. Eleven variables were analysed to see if there is any association with success. Outcome was measured twice, immediately after surgery prior to orthodontic loading (T1) and 12 months after surgery (T2). The outcome at T2 was assessed 12 months after the miniscrew's insertion date or after its use as a temporary anchorage device has ceased. Results. Overall success rate was 94.7% at T1 and 83.3% at T2. Multivariate analysis revealed only the length of miniscrew implant to be significantly associated with success at both T1 (P = 0.002) and T2 (P = 0.030). Miniscrew implants with lengths of 10-12 mm had the highest success rate (98.0%) compared to other lengths, and this is statistically significant (P = 0.035). At T2, lengths of 10-12 mm had significantly (P = 0.013) higher success rates (93.5%) compared to 6-7 mm (76.7%) and 8 mm (82.1%) miniscrew implants. Conclusion. Multivariate statistical analyses of 11 variables demonstrate that length of miniscrew implant is significant in determining success.

2.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-329351

ABSTRACT

A handy-type monitoring system for cardiovascular haemodynamic functions based on the volume-compensation and electrical admittance method is developed. In this system, the inconvenient and discomfort due to cuff occlusion of the biological segment for BP measurement is improved by developing a new device using a local pressurization method, the stability for the physiological information detection is improved by developing a new detecting system, and the noise during detection using the system is greatly reduced by using a newly developed nozzle-flapper type electro-pneumatic converter. Also, for electrical admittance cardiography to estimate CO, the applicability of a two-compartment coaxial cylindrical model and the optimal position of a spot-electrode array that is used to replace the conventional band-electrode are discussed in this research. Experimental result shows that the monitoring system should satisfy non-invasive BP and CO measurement on beat by beat, and the comfort of measurement is significantly improved.


Subject(s)
Cardiovascular Diseases , Diagnostic Techniques, Cardiovascular , Equipment Design , Hemodynamics , Monitoring, Physiologic , Methods
3.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-329314

ABSTRACT

An instantaneous blood pressure measuring system at the wrist based on the volume-compensation method is developed, and the characteristics and accuracy of the system is evaluated. The radial artery at the wrist is used as the detecting object, and a pad-type cuff as well as a newly designed electro- pneumatic converter is used in the system. Also, the comparative experiments between the system and the invasive blood measuring device (direct method) indicated that, the results obtained from the two methods are well correlated not only in rest condition, but also in a stressful condition. Therefore, the system is capable of non-invasive measuring instantaneous blood pressure in the radial artery.


Subject(s)
Humans , Blood Pressure Determination , Methods , Equipment Design , Radial Artery , Physiology