Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
2.
Heart Views ; 24(4): 210-211, 2023.
Article in English | MEDLINE | ID: mdl-38188707

ABSTRACT

Ticagrelor is available as an oral antiplatelet agent that can bind reversibly to the adenosine diphosphate receptor P2Y12 on platelets without first having to be activated. Main side effects such as dizziness, bleeding gums, nausea in common, difficulty in speaking, fever, and change in mental status are rare. Herein, we report a patient who had seizures after the usage of ticagrelor.

3.
Turk J Emerg Med ; 16(2): 53-56, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27896321

ABSTRACT

OBJECTIVES: We aimed to compare the performance of the C-MAC video laryngoscope (C-MAC) to the Macintosh laryngoscope for intubation of blunt trauma patients in the ED. MATERIAL AND METHODS: This was a prospective randomized study. The primary outcome measure is overall successful intubation. Secondary outcome measures are first attempt successful intubation, Cormack-Lehane (CL) grade, and indicators of the reasons for unsuccessful intubation at the first attempt with each device. Adult patients who suffered from blunt trauma and required intubation were randomized to video laryngoscopy with C-MAC device or direct laryngoscopy (DL). RESULTS: During a 17-month period, a total of 150 trauma intubations were performed using a C-MAC and DL. Baseline characteristics of patients were similar between the C-MAC and DL group. Overall success for the C-MAC was 69/75 (92%, 95% CI 0.83 to 0.96) while for the DL it was 72/75 (96%, 95% CI 0.88 to 0.98). First attempt success for the C-MAC was 47/75 (62.7%, 95% CI 0.51 to 0.72) while for the DL it was 44/75 patients (58.7%, 95% CI 0.47 to 0.69). The mean time to achieve successful intubation was 33.4 ± 2.5 s for the C-MAC versus 42.4 ± 5.1 s for the DL (p = 0.93). There was a statistically significant difference between the DL and C-MAC in terms of visualizing the glottic opening and esophageal intubation in favor of the C-MAC (p = 0.002 and p = 0.013 respectively). DISCUSSION AND CONCLUSION: The overall success rates were similar. The C-MAC demonstrated improved glottic view and decrease in esophageal intubation rate.

4.
J Emerg Med ; 50(3): e107-14, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26725922

ABSTRACT

BACKGROUND: Intubation is a fundamental skill in maintaining adequate oxygenation and ventilation of seriously ill patients. OBJECTIVES: To compare the C-MAC video laryngoscope and Bonfils intubation fiberscope with direct laryngoscopy in simulated easy and difficult airway scenarios. METHODS: This was a prospective, randomized-controlled cross-sectional study. Thirty emergency medicine residents attempted to intubate a manikin using four progressively more difficult airway settings (normal airway [scenario 1], cervical spine immobilization [scenario 2], cervical spine immobilization + tongue swelling scenario [scenario 3], and cervical spine immobilization + tongue swelling + limited jaw opening scenario [scenario 4]) with both the C-MAC video laryngoscope and the Bonfils intubation fiberscope and direct laryngoscope. RESULTS: In the first and the second scenarios, there were no statistically significant differences between the airway devices in terms of the duration of endotracheal intubation, the viewing duration of the glottic opening, and endotracheal tube insertion time. There was no statistically significant difference between the laryngoscopes in terms of the duration of endotracheal intubation and endotracheal tube insertion time in the third scenario. The overall success rates and the viewing duration of the glottic opening were shorter with the C-MAC and Bonfils in scenarios 3 and 4. Furthermore, the duration of intubation was better with Bonfils in scenario 4. The severity of dental trauma was lowest with the Bonfils in all scenarios. The device difficulty score was greatest with the Macintosh blade, except in the normal airway scenario. The most preferred airway device was the C-MAC. CONCLUSION: The Bonfils and C-MAC enabled better visualization of the glottic opening when compared with the Macintosh laryngoscope.


Subject(s)
Airway Management/methods , Intubation, Intratracheal/methods , Laryngoscopes , Laryngoscopy/methods , Cross-Sectional Studies , Humans , Laryngoscopy/instrumentation , Manikins , Prospective Studies , Video Recording
5.
Am J Emerg Med ; 34(2): 254-6, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26614580

ABSTRACT

OBJECTIVE: The aim of the study was to compare ultrasonography (US) and surface landmark techniques for detecting the cricothyroid membrane (CTM) to perform a cricothyroidotomy on healthy volunteers. METHODS: In this prospective observational study, 5 operators and 24 models were included. The borders of the CTM were marked with an invisible pen. The operators were asked to point the CTM either with the palpation method or the US-guided fashion. RESULTS: The CTM was detected accurately in 80 (66.7%) attempts with palpation and 83 (69.2%) attempts with US. There was no statistically significant difference in the accuracy of detection of the CTM with palpation and US. The mean time for detecting the CTM with palpation was 8.25 ± 4.8 seconds (95% confidence interval, 7.3-9.1). The mean time for detecting CTM with US was 17 ± 9.2 seconds (95% confidence interval, 15.3-18.7). The duration for detecting the localization of the CTM was longer with US. CONCLUSION: According to the results of this study, the accuracy of US and palpation was similar in detecting the localization of the CTM. However, the duration for detecting the CTM was longer with US when compared with the palpation technique.


Subject(s)
Cricoid Cartilage/diagnostic imaging , Cricoid Cartilage/surgery , Intubation, Intratracheal/methods , Palpation/methods , Physical Examination/methods , Thyroid Cartilage/diagnostic imaging , Thyroid Cartilage/surgery , Anatomic Landmarks , Female , Humans , Male , Point-of-Care Systems , Prospective Studies , Ultrasonography , Young Adult
6.
Turk J Emerg Med ; 15(2): 59-63, 2015 Jun.
Article in English | MEDLINE | ID: mdl-27336065

ABSTRACT

OBJECTIVES: Chronic Obstructive Pulmonary Disease (COPD) is associated with high mortality and morbidity and is projected to be the third most common cause of death worldwide by 2020. For a variety of reasons, there is a drive to manage a greater number of individuals as outpatients. Preventing readmissions can reduce associated morbidity and subsequent healthcare costs. METHODS: The aim of the present study was to determine the factors affecting the relapse of COPD exacerbated patients in the emergency department (ED). This study combines data from two prospective cohort studies. Patients included in the study were above 18 years of age, had a previous diagnosis of COPD, and presented to the ED for the treatment of acute exacerbation. All the information relevant to the study was collected during the patient's visit to the ED. Relapse was defined as an unscheduled visit to an ED or primary physician within 2 weeks of initial ED visit for worsening COPD symptoms. Telephone follow-up was done on all patients at the end of 2 weeks. RESULTS: The cohort consists of 196 patients. Relapse rate in this study was 27%. Mean respiratory rate, exacerbations in previous year, home nebulizator therapy, home oxygen therapy, admission to intensive care or hospital ward due to COPD exacerbation, previous intubation and abnormal chest x-ray were associated with increased re-visit in univariate analysis. However, after multivariate analysis, exacerbations in previous year (OR: 1.08, 95%CI: 1.01-1.15) and abnormal chest X-ray (OR: 2.5, 95%CI: 1.10-6.11) were still significant. CONCLUSIONS: In conclusion, the number of ED visits previous year and abnormal chest x-ray can predict the revisit of a COPD exacerbated patient within 14 days of an ED visit.

7.
Am J Emerg Med ; 31(7): 1034-6, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23702063

ABSTRACT

UNLABELLED: Prevention of secondary neurologic injury is critical during the airway management of a trauma patient. Trauma patients are assumed to have an unstable cervical spine (C-spine) until proven otherwise: orotracheal intubation during airway management may result in a certain amount of C-spine movement. This study, therefore, aimed to compare C-spine movement within different advanced airway devices (Macintosh blade, McCoy Blade, LMA, I-LMA, and Combitube) during airway management. MATERIALS AND METHODS: A total of 3 fresh frozen cadavers were used. The cadavers were consecutively intubated by 4 different postgraduate year residents with LMA4, I-LMA5, Combitube (37F), Macintosh 3, and McCoy blades. The cinefluoroscopic view of the entire intubation process was recorded, and vertebral body angles were calculated. RESULTS: At the C0C1 level, compared with the McCoy laryngoscope (median, 7°), the LMA (median, 2.5°) and the Combitube (median, 1.5°) caused less extension of the cervical vertebra. In addition, the Combitube (median, -1°) and the I-LMA (median, -2°) caused less extension of the C2C3 region when compared with the Macintosh laryngoscope (median, 3°). There was no significant difference between groups at the C1C2, C3C4, and C4C5 segments. CONCLUSION: Supraglottic devices used during airway management cause C-spine movement less or equal to conventional laryngoscopes. Furthermore, because of ease of training and blind insertion, supraglottic devices can be safely used with trauma patients when C-spine integrity is a concern.


Subject(s)
Cervical Vertebrae/physiology , Intubation, Intratracheal/instrumentation , Cervical Vertebrae/diagnostic imaging , Cineradiography , Humans , Intubation, Intratracheal/adverse effects , Intubation, Intratracheal/methods , Laryngeal Masks/adverse effects , Laryngoscopes/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...