Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Zhongguo Gu Shang ; 35(4): 317-22, 2022 Apr 25.
Article in Chinese | MEDLINE | ID: mdl-35485145

ABSTRACT

OBJECTIVE: To investigate the effect of internal external fixator assisted O-arm navigation imaging in the treatment of unstable pelvic fractures. METHODS: From May 2019 to November 2019, 15 patients with unstable pelvic fractures were treated by intraoperative O-arm navigation imaging using INFIX technology. There were 6 males and 9 females. The age ranged from 24 to 66 years old. The course of disease ranged from 2 to 14 days. According to Tile classification, there were 1 case of B1 type, 8 cases of B2 type, 3 cases of C1 type, and 3 cases of C2 type. According to Young-Burgess classification, there were 8 cases of LC, 1 case of APC, 4 cases of VS, 2 cases of CM. Preoperative routine pelvic anteroposterior film, entrance position, exit position and pelvic CT three-dimensional reconstruction were performed. Intraoperative O-arm navigation system three-dimensional reconstruction and triplane scanning imaging were used to evaluate the effect of intraoperative reduction. The anterior pelvic ring was fixed with internal external fixator, and the posterior ring was fixed with sacroiliac screw, plate screw or lumbar iliac screw. The operation time, intraoperative bleeding and nail placement were observed and recorded. The quality of fracture reduction was evaluated by Matta standard, and the postoperative function was evaluated by Majeed function score. RESULTS: Wound healing was good in all patients without vascular, nerve and local irritation complications. All the 15 patients were followed up for 10 to 16 months. The fracture reduction was evaluated according to the Matta scoring standard, 9 cases were excellent results, 5 cases were good, and 1 case was medium. The Majeed functional score was 0 to 95 points. CONCLUSION: The built-in external fixator assisted O-arm navigation imaging system in the treatment of unstable pelvic fractures. The reduction effect is evaluated in advance, the operation time is shortened, and the accuracy of internal fixation is improved. The operation is simple, safe and less bleeding. The operation is in line with the principles of minimally invasive medical treatment and precision medical treatment in orthopedics, which is conducive to the recovery of patients' postoperative function and rapid recovery.


Subject(s)
Fractures, Bone , Surgery, Computer-Assisted , Adult , Aged , Bone Plates , Female , Fracture Fixation, Internal/methods , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Tomography, X-Ray Computed , Young Adult
2.
World J Clin Cases ; 9(18): 4760-4764, 2021 Jun 26.
Article in English | MEDLINE | ID: mdl-34222444

ABSTRACT

BACKGROUND: Clinical femoral neck fracture is common. Based on patient age and fracture type, different surgical methods can be selected, including cannulated screw fixation of the femoral neck and artificial total hip joint or semi-hip joint replacement. When patients with femoral neck fracture are treated with cannulated screw fixation, a cannulated screw may be positioned too deep. The excessively deep-placed screw is difficult to remove and causes major trauma to the patient. CASE SUMMARY: A patient with poliomyelitis and femoral neck fracture was treated with a cannulated screw that was placed too deep. A self-made auxiliary tool (made of a steel sternal wire) was used to remove the cannulated screw near the pelvic cavity. CONCLUSION: The depth of the cannulated screw can be estimated before screw placement using an improved hollow screwdriver with a scale mark, thus improving the safety of screw placement and facilitating clinical use.

SELECTION OF CITATIONS
SEARCH DETAIL
...