Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
2.
Neurosurg Focus ; 37(1 Suppl): 1, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24983719

ABSTRACT

We report the case of a 62-year-old female who presented for stent-assistant coiling of an incidental 11-mm complex bilobed left superior hypophyseal internal carotid artery aneurysm. A microcatheter was navigated into the aneurysm and trapped by a 37-mm stent. Using three-dimensional and two-dimensional coils, the elongated aneurysm was coiled. The bigger lobe was coiled first followed by the smaller lobe. Minimal residual filling of the smaller lobe will be re-evaluated at 6-month follow up. The patient tolerated the procedure well and no complications were encountered. The video can be found here: http://youtu.be/TrXfsaICQVo .


Subject(s)
Carotid Artery Diseases/therapy , Carotid Artery, Internal , Embolization, Therapeutic/methods , Intracranial Aneurysm/therapy , Female , Humans , Middle Aged , Pituitary Gland , Stents
5.
J Thorac Cardiovasc Surg ; 144(2): 370-6, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22154793

ABSTRACT

OBJECTIVE: This study compares 2-dimensional, transthoracic echocardiography with cardiac magnetic resonance imaging in the preoperative identification of bicuspid aortic valve before aortic valve surgery. METHODS: Of 1203 patients who underwent an aortic valve operation, 218 had both preoperative transthoracic echocardiography and cardiac magnetic resonance imaging. Patients in the study group were aged 56 years and had an ejection fraction of 56%, 76% were male, and 29% had associated coronary artery disease. The results of transthoracic echocardiography and cardiac magnetic resonance imaging were classified as bicuspid aortic valve, trileaflet aortic valve, or nondiagnostic. Of the 218 patients, 123 (56%) had bicuspid aortic valve as determined at the time of surgery and 116 (53%) had an ascending aortic aneurysm. RESULTS: Of the 123 patients with bicuspid aortic valve confirmed at surgery, by transthoracic echocardiography 76 (62%) were identified preoperatively with bicuspid aortic valve, 12 (10%) were misidentified with trileaflet aortic valve, and 35 (28%) were nondiagnostic for valve morphology. In the same patients with bicuspid aortic valve, by cardiac magnetic resonance imaging 115 (93%) were identified with bicuspid aortic valve, 5 (4%) were misidentified with trileaflet aortic valve, and 3 (2%) were nondiagnostic. The difference between transthoracic echocardiography and cardiac magnetic resonance imaging to determine the presence of bicuspid aortic valve was statistically significant (P<.001). In the entire cohort of patients, transthoracic echocardiography was diagnostic for valve morphology in 155 patients (71%) compared with cardiac magnetic resonance imaging, which was diagnostic in 212 patients (97%) (P<.001). CONCLUSIONS: Cardiac magnetic resonance imaging is more diagnostic than transthoracic echocardiography in determining the presence of bicuspid aortic valve. A significant factor is the rate of nondiagnostic transthoracic echocardiography for aortic valve morphology. Cardiac magnetic resonance imaging can be performed as a complementary test when transthoracic echocardiography is nondiagnostic for aortic valve morphology.


Subject(s)
Aortic Valve/pathology , Aortic Valve/surgery , Adult , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Preoperative Period , Retrospective Studies , Ultrasonography , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...