ABSTRACT

<p><b>OBJECTIVE</b>To develop a method for determination of 2, 4-dichlorophenoxyacetic acid (2, 4-D) in the air of workplace by high-performance liquid chromatography.</p><p><b>METHODS</b>2, 4-D was collected by ultrafine glass filters, desorbed by methanol, separated by a C18 column, and detected by a UV detector. Identification and quantification of 2, 4-D were performed by retention time and peak areas, respectively.</p><p><b>RESULTS</b>The linear range of the test was 2∼200 µg/ml; the elution efficiency was 94.6%- 95.9%; the limit of detection (S/N = 3) was 0.034 µg/ml (injection volume of 20 µl eluant); the lower limit of quantification (S/N = 10) was 0.11 µg/ml; the minimum detectable concentration was 0.011 mg/m(3); the minimum quantifiable concentration was 0.037 mg/m(3) (with sampled air volume of 45 L).</p><p><b>CONCLUSION</b>This method is convenient and simple in sample collection and preparation, and satisfies all methodological requirements. Therefore, this method is useful for the determination of 2, 4-D in the air of workplace.</p>


Subject(s)
2,4-Dichlorophenoxyacetic Acid , Air , Air Pollutants, Occupational , Chromatography, High Pressure Liquid , Methods , Workplace