Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Bone ; 144: 115770, 2021 03.
Article in English | MEDLINE | ID: mdl-33249321

ABSTRACT

PURPOSE: To investigate the effects of sequential therapy with monthly intravenous ibandronate on bone mineral density (BMD) and microstructure in patients with primary osteoporosis who received teriparatide treatment. METHODS: Sixty-six patients with primary osteoporosis who had undergone teriparatide treatment for more than 12 months (mean 18.6 months) received sequential therapy with 1 mg/month intravenous ibandronate for 12 months. The patients were evaluated using dual-energy X-ray absorptiometry (DXA), quantitative ultrasound, bone turnover markers, and high-resolution peripheral quantitative computed tomography (HR-pQCT) at baseline and 6 and 12 months after beginning administration. RESULTS: At 12 months after beginning sequential therapy, the bone resorption marker, tartrate-resistant acid phosphatase-5b, decreased by 39.5%, with 82.3% of the patients exhibiting levels within the normal limit. DXA revealed that the BMD of the lumbar spine increased by 3.2%, with 79.0% of the patients exhibiting a response, and 40.3% experiencing an increase in BMD over 5%. HR-pQCT revealed that the cortical thickness of the distal tibia was increased by 2.6%. The cortical area increased by 2.5%, and the buckling ratio (an index of cortical instability) decreased by 2.5%. Most parameters of the trabecular bone showed no significant changes. These changes in the cortical bone were observed in both the distal radius and tibia and appeared beginning 6 months after treatment initiation. CONCLUSIONS: Sequential therapy with monthly intravenous ibandronate increased the BMD and improved the cortical bone microstructure of osteoporotic patients who had undergone teriparatide treatment.


Subject(s)
Bone Density Conservation Agents , Osteoporosis , Absorptiometry, Photon , Bone Density , Bone Density Conservation Agents/therapeutic use , Humans , Ibandronic Acid , Osteoporosis/diagnostic imaging , Osteoporosis/drug therapy , Teriparatide/therapeutic use
2.
PLoS One ; 9(10): e107588, 2014.
Article in English | MEDLINE | ID: mdl-25299658

ABSTRACT

Biofilms forming on the surface of biomaterials can cause intractable implant-related infections. Bacterial adherence and early biofilm formation are influenced by the type of biomaterial used and the physical characteristics of implant surface. In this in vitro research, we evaluated the ability of Staphylococcus epidermidis, the main pathogen in implant-related infections, to form biofilms on the surface of the solid orthopaedic biomaterials, oxidized zirconium-niobium alloy, cobalt-chromium-molybdenum alloy (Co-Cr-Mo), titanium alloy (Ti-6Al-4V), commercially pure titanium (cp-Ti) and stainless steel. A bacterial suspension of Staphylococcus epidermidis strain RP62A (ATCC35984) was added to the surface of specimens and incubated. The stained biofilms were imaged with a digital optical microscope and the biofilm coverage rate (BCR) was calculated. The total amount of biofilm was determined with the crystal violet assay and the number of viable cells in the biofilm was counted using the plate count method. The BCR of all the biomaterials rose in proportion to culture duration. After culturing for 2-4 hours, the BCR was similar for all materials. However, after culturing for 6 hours, the BCR for Co-Cr-Mo alloy was significantly lower than for Ti-6Al-4V, cp-Ti and stainless steel (P<0.05). The absorbance value determined in the crystal violet assay and the number of viable cells on Co-Cr-Mo were not significantly lower than for the other materials (P>0.05). These results suggest that surface properties, such as hydrophobicity or the low surface free energy of Co-Cr-Mo, may have some influence in inhibiting or delaying the two-dimensional expansion of biofilm on surfaces with a similar degree of smoothness.


Subject(s)
Biocompatible Materials/therapeutic use , Biofilms/growth & development , Prostheses and Implants/microbiology , Staphylococcus epidermidis/growth & development , Alloys/therapeutic use , Bacterial Adhesion/physiology , Hydrophobic and Hydrophilic Interactions , Orthopedics/methods , Staphylococcal Infections/microbiology , Surface Properties
3.
BMC Microbiol ; 14: 234, 2014 Sep 02.
Article in English | MEDLINE | ID: mdl-25179448

ABSTRACT

BACKGROUND: Implant-related infections are caused by adhesion of bacteria to the surface of biomaterials. In this in vitro research, we evaluated the ability of Staphylococcus epidermidis (ATCC35984) to adhere to the surface of solid biomaterials at different levels of roughness below 30 nm Ra and investigated the minimum level of roughness required to promote bacterial adhesion on five kinds of biomaterials: oxidized zirconium-niobium alloy (Oxinium), cobalt-chromium-molybdenum alloy (Co-Cr-Mo), titanium alloy (Ti-6Al-4 V), commercially pure titanium (Cp-Ti) and stainless steel (SUS316L), samples of which were categorized into a fine group and a coarse group according to surface roughness. The test specimens were physically analyzed and the viable bacterial density of the adhered bacteria was quantitatively determined (n = 20). RESULTS: The amount of bacteria that adhered to the biomaterials in the coarse group was higher than those in the fine group. Oxinium, Ti-6Al-4 V and SUS316L in particular demonstrated statistically significant differences between the two groups (P < 0.05). Of the materials, the Co-Cr-Mo specimens exhibited significantly lower amounts of adhered bacteria than the Ti-6Al-4 V, Cp-Ti and SUS316L specimens in the fine group. Similarly, the Co-Cr-Mo specimens in the coarse group exhibited significantly lower values than the other four materials. CONCLUSIONS: These results suggest that minimum level of roughness affecting initial bacterial adherence activity differs according to the type of biomaterial used, and that even a surface roughness of below 30 nm Ra in Oxinium, Ti-6Al-4 V and SUS316L can promote bacterial adhesion. Relative hydrophobic Co-Cr-Mo surfaces were less susceptible to bacterial adherence.


Subject(s)
Bacterial Adhesion , Biocompatible Materials , Staphylococcus epidermidis/physiology , Surface Properties , Colony Count, Microbial , Humans , Microbial Viability , Microscopy, Electron, Scanning
4.
Int J Nanomedicine ; 8: 3955-61, 2013.
Article in English | MEDLINE | ID: mdl-24143100

ABSTRACT

Bacterial adhesion to the surface of biomaterials is an essential step in the pathogenesis of implant-related infections. In this in vitro research, we evaluated the ability of Staphylococcus epidermidis to adhere to the surface of solid biomaterials, including oxidized zirconium-niobium alloy (Oxinium), cobalt-chromium-molybdenum alloy, titanium alloy, commercially pure titanium, and stainless steel, and performed a biomaterial-to-biomaterial comparison. The test specimens were physically analyzed to quantitatively determine the viable adherent density of the S. epidermidis strain RP62A (American Type Culture Collection [ATCC] 35984). Field emission scanning electron microscope and laser microscope examination revealed a featureless, smooth surface in all specimens (average roughness <10 nm). The amounts of S. epidermidis that adhered to the biomaterial were significantly lower for Oxinium and the cobalt-chromium-molybdenum alloy than for commercially pure titanium. These results suggest that Oxinium and cobalt-chromium-molybdenum alloy are less susceptible to bacterial adherence and are less inclined to infection than other materials of a similar degree of smoothness.


Subject(s)
Bacterial Adhesion/physiology , Biocompatible Materials/pharmacology , Equipment Contamination/prevention & control , Metals/pharmacology , Prostheses and Implants/microbiology , Staphylococcus epidermidis/cytology , Staphylococcus epidermidis/physiology , Bacterial Adhesion/drug effects , Biocompatible Materials/chemistry , Materials Testing , Metals/chemistry
5.
Int J Nanomedicine ; 8: 593-9, 2013.
Article in English | MEDLINE | ID: mdl-23429667

ABSTRACT

BACKGROUND: Pin site infection is the most common and significant complication of external fixation. In this work, the efficacy of pins coated with titanium dioxide (TiO(2)) for inhibition of infection was compared with that of stainless steel control pins in an in vivo study. METHODS: Pins contaminated with an identifiable Staphylococcus aureus strain were inserted into femoral bone in a rat model and exposed to ultraviolet A light for 30 minutes. On day 14, the animals were sacrificed and the bone and soft tissue around the pin were retrieved. The clinical findings and histological findings were evaluated in 60 samples. RESULTS: Clinical signs of infection were present in 76.7% of untreated pins, but in only 36.7% of TiO(2)-coated pins. The histological bone infection score and planimetric rate of occupation for bacterial colonies and neutrophils in the TiO(2)-coated pin group were lower than those in the control group. The bone-implant contact ratio of the TiO(2)-coated pin group was significantly higher (71.4%) than in the control pin group (58.2%). The TiO(2) was successful in decreasing infection both clinically and histomorphometrically. CONCLUSION: The photocatalytic bactericidal effect of TiO(2) is thought to be useful for inhibiting pin site infection after external fixation.


Subject(s)
Anti-Bacterial Agents/administration & dosage , Anti-Bacterial Agents/chemistry , Bone Nails , External Fixators , Titanium/administration & dosage , Titanium/chemistry , Animals , Bone Diseases, Infectious/prevention & control , Female , Femur/surgery , Histocytochemistry , Rats , Rats, Sprague-Dawley , Staphylococcal Infections/prevention & control , Staphylococcus aureus/drug effects , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...