Med Phys ; 48(8): 4148-4159, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34032301

ABSTRACT

PURPOSE: The implementation of volumetric in-room imaging for online adaptive radiotherapy makes extensive testing of this image data for treatment planning necessary. Especially for proton beams the higher sensitivity to stopping power properties of the tissue results in more stringent requirements. Current approaches mainly focus on recalculation of the plans on the new image data, lacking experimental verification, and ignoring the impact on the plan re-optimization process. The aim of this study was to use gel and film dosimetry coupled with a three-dimensional (3D) printed head phantom (based on the planning CT of the patient) for 3D range verification of intensity-corrected cone beam computed tomography (CBCT) image data for adaptive proton therapy. METHODS: Single field uniform dose pencil beam scanning proton plans were optimized for three different patients on the patients' planning CT (planCT) and the patients' intensity-corrected CBCT (scCBCT) for the same target volume using the same optimization constraints. The CBCTs were corrected on projection level using the planCT as a prior. The dose optimized on planCT and recalculated on scCBCT was compared in terms of proton range differences (80% distal fall-off, recalculation). Moreover, the dose distribution resulting from recalculation of the scCBCT-optimized plan on the planCT and the original planCT dose distribution were compared (simulation). Finally, the two plans of each patient were irradiated on the corresponding patient-specific 3D printed head phantom using gel dosimetry inserts for one patient and film dosimetry for all three patients. Range differences were extracted from the measured dose distributions. The measured and the simulated range differences were corrected for range differences originating from the initial plans and evaluated. RESULTS: The simulation approach showed high agreement with the standard recalculation approach. The median values of the range differences of these two methods agreed within 0.1 mm and the interquartile ranges (IQRs) within 0.3 mm for all three patients. The range differences of the film measurement were accurately matching with the simulation approach in the film plane. The median values of these range differences deviated less than 0.1 mm and the IQRs less than 0.4 mm. For the full 3D evaluation of the gel range differences, the median value and IQR matched those of the simulation approach within 0.7 and 0.5 mm, respectively. scCBCT- and planCT-based dose distributions were found to have a range agreement better than 3 mm (median and IQR) for all considered scenarios (recalculation, simulation, and measurement). CONCLUSIONS: The results of this initial study indicate that an online adaptive proton workflow based on scatter-corrected CBCT image data for head irradiations is feasible. The novel presented measurement- and simulation-based method was shown to be equivalent to the standard literature recalculation approach. Additionally, it has the capability to catch effects of image differences on the treatment plan optimization. This makes the measurement-based approach particularly interesting for quality assurance of CBCT-based online adaptive proton therapy. The observed uncertainties could be kept within those of the registration and positioning. The proposed validation could also be applied for other alternative in-room images, e.g. for MR-based pseudoCTs.


Subject(s)
Proton Therapy , Radiotherapy, Intensity-Modulated , Spiral Cone-Beam Computed Tomography , Cone-Beam Computed Tomography , Humans , Image Processing, Computer-Assisted , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
2.
J Appl Clin Med Phys ; 18(4): 144-154, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28585287

ABSTRACT

Tumor tracking is an option for intra-fractional motion management in radiotherapy. The VERO gimbal tracking system creates a unique beam geometry and understanding the effect of the gimbal motion in terms of dose distribution is important to assess the dose deviation from the reference conditions. Beam profiles, output factors (OF) and percentage depth doses (PDD) were measured and evaluated to investigate this effect. In order to find regions affected by the pan-tilt motion, synthesized 2D dose distributions were generated. An evaluation of the 2D dose distribution with the reference position was done using dose difference criteria 1%-4%. The OF and point dose at central axis were measured and compared with the reference position. Furthermore, the PDDs were measured using a special monitoring approach to filtering inaccurate points during the acquisition. Beam profiles evaluation showed that the effect of pan-tilt at inline direction was stronger than at the crossline direction. The maximum average deviation of the full width half maximum (FWHM), flatness, symmetry, penumbra left and right were 0.39 ± 0.25 mm, 0.62 ± 0.50%, 0.76 ± 0.59%, 0.22 ± 0.16 mm, and 0.19 ± 0.15 mm respectively. The ÔF and the measured dose average deviation were <0.5%. The mechanical accuracies during the PDD measurements were 0.28 ± 0.09 mm and 0.21 ± 0.09 mm for pan and tilt and pan or tilt position. The PDD average deviations were 0.58 ± 0.26 % and 0.54 ± 0.25 % for pan-or-tilt and pan-and-tilt position respectively. All the results showed that the deviation at pan and tilt position are higher than pan or tilt. The most influences were observed for the penumbra region and the shift of radiation beam path.


Subject(s)
Neoplasms/diagnostic imaging , Neoplasms/radiotherapy , Organ Motion , Radiotherapy Dosage , Humans
3.
Strahlenther Onkol ; 193(8): 656-665, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28653120

ABSTRACT

BACKGROUND: Intensity-modulated radiotherapy (IMRT) techniques are now standard practice. IMRT or volumetric-modulated arc therapy (VMAT) allow treatment of the tumor while simultaneously sparing organs at risk. Nevertheless, treatment plan quality still depends on the physicist's individual skills, experiences, and personal preferences. It would therefore be advantageous to automate the planning process. This possibility is offered by the Pinnacle3 treatment planning system (Philips Healthcare, Hamburg, Germany) via its scripting language or Auto-Planning (AP) module. MATERIALS AND METHODS: AP module results were compared to in-house scripts and manually optimized treatment plans for standard head and neck cancer plans. Multiple treatment parameters were scored to judge plan quality (100 points = optimum plan). Patients were initially planned manually by different physicists and re-planned using scripts or AP. RESULTS AND DISCUSSION: Script-based head and neck plans achieved a mean of 67.0 points and were, on average, superior to manually created (59.1 points) and AP plans (62.3 points). Moreover, they are characterized by reproducibility and lower standard deviation of treatment parameters. Even less experienced staff are able to create at least a good starting point for further optimization in a short time. However, for particular plans, experienced planners perform even better than scripts or AP. Experienced-user input is needed when setting up scripts or AP templates for the first time. Moreover, some minor drawbacks exist, such as the increase of monitor units (+35.5% for scripted plans). CONCLUSION: On average, automatically created plans are superior to manually created treatment plans. For particular plans, experienced physicists were able to perform better than scripts or AP; thus, the benefit is greatest when time is short or staff inexperienced.


Subject(s)
Algorithms , Head and Neck Neoplasms/radiotherapy , Programming Languages , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Computer-Assisted , Software , Humans , Radiotherapy Dosage , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome , Tumor Burden/radiation effects
4.
J Appl Clin Med Phys ; 17(4): 106-113, 2016 07 08.
Article in English | MEDLINE | ID: mdl-27455496

ABSTRACT

We report an investigation on the accuracy of dose calculation based on the cone-beam computed tomography (CBCT) images of the nonbowtie filter kV imaging system of the Vero linear accelerator. Different sets of materials and tube voltages were employed to generate the Hounsfield unit lookup tables (HLUTs) for both CBCT and fan-beam CT (FBCT) systems. The HLUTs were then implemented for the dose calculation in a treatment planning system (TPS). Dosimetric evaluation was carried out on an in-house-developed cube phantom that consists of water-equivalent slabs and inhomogeneity inserts. Two independent dosimeters positioned in the cube phantom were used in this study for point-dose and two-dimensional (2D) dose distribution measurements. The differences of HLUTs from various materials and tube voltages in both CT systems resulted in differences in dose calculation accuracy. We found that the higher the tube voltage used to obtain CT images, the better the point-dose calculation and the gamma passing rate of the 2D dose distribution agree to the values determined in the TPS. Moreover, the insert materials that are not tissue-equivalent led to higher dose-calculation inaccuracy. There were negligible differences in dosimetric evaluation between the CBCT- and FBCT-based treatment planning if the HLUTs were generated using the tissue-equivalent materials. In this study, the CBCT images of the Vero system from a complex inhomogeneity phantom can be applied for the TPS dose calculation if the system is calibrated using tissue-equivalent materials scanned at high tube voltage (i.e., 120 kV).


Subject(s)
Cone-Beam Computed Tomography/methods , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/instrumentation , Radiotherapy, Intensity-Modulated/methods , Calibration , Humans , Particle Accelerators , Radiotherapy Dosage
5.
Med Phys ; 43(1): 308, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26745924

ABSTRACT

PURPOSE: Five tissue- and water-equivalent materials (TEMs) mimicking ICRU real tissues have been formulated using a previously established stoichiometric analysis method (SAM) to be applied in charged particle therapy. The purpose of this study was an experimental verification of the TEMs-SAM against charged particle beam measurements and for different computed tomography (CT) scanners. The potential of the TEMs-SAM to be employed in the dosimetry was also investigated. METHODS: Experimental verification with three CT scanners was carried out to validate the calculated Hounsfield units (HUs) of the TEMs. Water-equivalent path lengths (WEPLs) of the TEMs for proton (106.8 MeV/u), helium (107.93 MeV/u), and carbon (200.3 MeV/u) ions were measured to be compared with the computed relative stopping powers. HU calibration curves were also generated. RESULTS: Differences between the measured HUs of the TEMs and the calculated HUs of the ICRU real tissues for all CT scanners were smaller than 4 HU except for the skeletal tissues which deviated up to 21 HU. The measured WEPLs verified the calculated WEPLs of the TEMs (maximum deviation was 0.17 mm) and were in good agreement with the calculated WEPLs of the ICRU real tissues (maximum deviation was 0.23 mm). Moreover, the relative stopping powers converted from the measured WEPLs differed less than 0.8% and 1.3% from the calculated values of the SAM and the ICRU, respectively. Regarding the relative nonelastic cross section per unit of volume for 200 MeV protons, the ICRU real tissues were generally well represented by the TEMs except for adipose which differed 3.8%. Further, the HU calibration curves yielded the mean and the standard deviation of the errors not larger than 0.5% and 1.9%, respectively. CONCLUSIONS: The results of this investigation implied the potential of the TEMs formulated using the SAM to be employed for both, beam dosimetry and HU calibration in charged particle therapy.


Subject(s)
Biomimetic Materials , Radiotherapy/methods , Water , Calibration , Tomography, X-Ray Computed
6.
J Appl Clin Med Phys ; 16(6): 84­90, 2015 11 08.
Article in English | MEDLINE | ID: mdl-26699558

ABSTRACT

Noncoplanar fields are normally used to improve the dose conformity of the target while sparing organs at risk. One of the methods to verify the dose distribution from the noncoplanar fields is by comparing their planar dose distributions from the treatment planning system (TPS) and the measured ones; for example, using film or electronic portal imaging devices (EPID). The planar dose distributions of the measurement tools, that are normally perpendicular to the central axis of the beam, can be calculated by creating special structures to mimic them in the TPS. With TPS commercially available today, however, it is not easy to create these special structures, especially in the noncoplanar configuration. For this work, we have written in-house scripts in the Pinnacle(3) TPS that can create the structures and define them as virtual planes. These virtual planes can be generated for any arbitrary gantry and couch angles, as well as source to planar distance, so that the planar dose maps at these planes can be computed. Two independent quality assurance (QA) tools were used to validate the planar dose distributions computed using the scripts for three open fields and one IMRT field at several different couch angles. The absolute planar dose patterns measured by the QA tools for all fields at all couch angles were found to be in good agreement, more than 95% (gamma criteria 3% delta dose and 3 mm distance to agreement), with the calculated ones by TPS. The results of this feasibility study can be valuable either for pretreatment dose verification or for in vivo dosimetry that directly implements the planar dose distributions from the TPS, particularly for the noncoplanar fields.


Subject(s)
Radiotherapy Planning, Computer-Assisted/methods , Calibration , Feasibility Studies , Film Dosimetry , Humans , Organs at Risk , Quality Assurance, Health Care , Radiometry/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/standards , Radiotherapy Planning, Computer-Assisted/statistics & numerical data , Tomography, X-Ray Computed , User-Computer Interface
7.
Phys Med ; 30(7): 809-15, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25172392

ABSTRACT

This report, compiled by experts on the treatment of mobile targets with advanced radiotherapy, summarizes the main conclusions and innovations achieved during the 4D treatment planning workshop 2013. This annual workshop focuses on research aiming to advance 4D radiotherapy treatments, including all critical aspects of time resolved delivery, such as in-room imaging, motion detection, motion managing, beam application, and quality assurance techniques. The report aims to revise achievements in the field and to discuss remaining challenges and potential solutions. As main achievements advances in the development of a standardized 4D phantom and in the area of 4D-treatment plan optimization were identified. Furthermore, it was noticed that MR imaging gains importance and high interest for sequential 4DCT/MR data sets was expressed, which represents a general trend of the field towards data covering a longer time period of motion. A new point of attention was work related to dose reconstructions, which may play a major role in verification of 4D treatment deliveries. The experimental validation of results achieved by 4D treatment planning and the systematic evaluation of different deformable image registration methods especially for inter-modality fusions were identified as major remaining challenges. A challenge that was also suggested as focus for future 4D workshops was the adaptation of image guidance approaches from conventional radiotherapy into particle therapy. Besides summarizing the last workshop, the authors also want to point out new evolving demands and give an outlook on the focus of the next workshop.


Subject(s)
Education , Four-Dimensional Computed Tomography , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Image-Guided , Magnetic Resonance Imaging , Movement
8.
Phys Med Biol ; 57(5): 1173-90, 2012 Mar 07.
Article in English | MEDLINE | ID: mdl-22330195

ABSTRACT

Tissue- and water-equivalent materials (TEMs) are widely used in quality assurance and calibration procedures, both in radiodiagnostics and radiotherapy. In radiotherapy, particularly, the TEMs are often used for computed tomography (CT) number calibration in treatment planning systems. However, currently available TEMs may not be very accurate in the determination of the calibration curves due to their limitation in mimicking radiation characteristics of the corresponding real tissues in both low- and high-energy ranges. Therefore, we are proposing a new formulation of TEMs using a stoichiometric analysis method to obtain TEMs for the calibration purposes. We combined the stoichiometric calibration and the basic data method to compose base materials to develop TEMs matching standard real tissues from ICRU Report 44 and 46. First, the CT numbers of six materials with known elemental compositions were measured to get constants for the stoichiometric calibration. The results of the stoichiometric calibration were used together with the basic data method to formulate new TEMs. These new TEMs were scanned to validate their CT numbers. The electron density and the stopping power calibration curves were also generated. The absolute differences of the measured CT numbers of the new TEMs were less than 4 HU for the soft tissues and less than 22 HU for the bone compared to the ICRU real tissues. Furthermore, the calculated relative electron density and electron and proton stopping powers of the new TEMs differed by less than 2% from the corresponding ICRU real tissues. The new TEMs which were formulated using the proposed technique increase the simplicity of the calibration process and preserve the accuracy of the stoichiometric calibration simultaneously.


Subject(s)
Radiotherapy Planning, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Algorithms , Calibration , Electrons , Humans , Models, Statistical , Phantoms, Imaging , Radiation Oncology/methods , Reproducibility of Results , Software , Tissue Distribution , Water/chemistry
9.
Phys Med Biol ; 56(10): 2963-77, 2011 May 21.
Article in English | MEDLINE | ID: mdl-21490386

ABSTRACT

Tissue-equivalent materials are used for simplifying quality control and quality assurance procedures, both in diagnostic and therapeutic radiology. Important information to formulate a tissue-equivalent material is elemental composition of its base materials. However, this information is not easily obtained. Therefore we propose a stoichiometric analysis method to investigate the elemental composition of the base materials that can potentially be used for manufacturing tissue-equivalent materials. In this technique, we combined the stoichiometric calibration and the basic data method to obtain the elemental composition of materials from measured computer tomography (CT) numbers. The elemental composition, with the maximum number of the elements of the material in question up to the available number of different tube voltages at the CT scanner, was analysed using the proposed approach. We tested eight different cylinders in this study. The estimated elemental compositions of unspecified materials in the cylinders were evaluated by comparing the calculated and the simulated CT numbers to the measured ones; the results showed good correlation with maximum absolute differences of 1.9 and 3.7 HU, respectively. The accuracy of the stoichiometric analysis method to estimate the elemental composition was influenced by the accuracy of the measured CT numbers. The method proposed allows for determining the elemental composition of the base materials which can then be applied further to formulate tissue-equivalent materials.


Subject(s)
Phantoms, Imaging , Calibration , Tomography, X-Ray Computed