Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Med Primatol ; 36(1): 39-46, 2007 Feb.
Article in English | MEDLINE | ID: mdl-17359465

ABSTRACT

BACKGROUND: The purpose of this study was to investigate the feasibility of evaluating cardiac function by real time three-dimensional (RT3D) echocardiography in isoflurane-anesthetized male cynomolgus monkeys. Additionally differences between inhibitory effects of beta-blockers and a Ca channel blocker on left ventricular (LV) function were examined. METHODS AND RESULTS: End-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) in the control (without any drug effect) were not significantly changed by repetitive measurement at a 30-day interval. Propranolol and metoprolol (0.1 and 0.3 mg/kg/10 minutes, i.v.) caused a dose-dependent increase in ESV, but little effect on EDV, resulting in a decrease in EF. Verapamil (0.1 and 0.3 mg/kg/10 minutes, i.v.) increased both EDV and ESV, but decreased EF was noted at 0.3 mg/kg. CONCLUSIONS: These results demonstrate the feasibility of RT3D echocardiography in providing reproducible estimations of LV volume and EF in monkeys when evaluating drugs that may affect cardiac function.


Subject(s)
Echocardiography, Three-Dimensional/methods , Macaca fascicularis/physiology , Ventricular Function , Adrenergic beta-Antagonists/pharmacology , Animals , Calcium Channel Blockers/pharmacology , Heart Ventricles/drug effects , Male , Metoprolol/pharmacology , Propranolol/pharmacology , Verapamil/pharmacology
2.
J Pharmacol Toxicol Methods ; 52(1): 182-7, 2005.
Article in English | MEDLINE | ID: mdl-15935708

ABSTRACT

INTRODUCTION: A timed non-invasive determination of cardiac function is potentially important for safety pharmacology and toxicity studies. The objectives of this study were to evaluate the accuracy of real-time three-dimensional (RT3D) echocardiography measurements of the left ventricular (LV) volume and LV function and to investigate the effects of some drugs on LV function in cynomolgus monkeys. METHODS: RT3D echocardiography was performed (SONOS 7500, Philips Med Sys) under isoflurane inhalation. RT3D echocardiography measurements and reconstructions were obtained using Tom-Tec (4DLV analysis). We determined end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), stroke volume (SV), cardiac output (CO) and heart rate as assessments of LV function. EDV, calculated from two-dimensional (2D) echocardiography and RT3D echocardiography, and the actual LV volume were evaluated and compared. Furthermore, each parameter was determined before and after intravenous infusion (5 or 10 min) of propranolol, verapamil and dobutamine. RESULTS: A strong correlation was found between the actual LV volume and that calculated from RT3D echocardiography (r=0.96, p<0.001). Propranolol (0.1 mg/kg/10 min, n=5) caused an increase in ESV, but not EDV, resulting in a decrease in EF and SV, while verapamil produced increases in both EDV and ESV. Dobutamine (0.01 mg/kg/5 min, n=5) produced decreases in both EDV and ESV and thereby the increased CO resulted from the increased SV. DISCUSSION: These results demonstrate that RT3D echocardiography provides a feasible and accurate estimation of LV volume and EF for safety pharmacology and toxicity studies.


Subject(s)
Cardiovascular Agents/adverse effects , Drug Evaluation, Preclinical/methods , Echocardiography, Three-Dimensional/methods , Macaca fascicularis , Ventricular Function, Left/drug effects , Animals , Cardiovascular Agents/classification , Dobutamine/adverse effects , Injections, Intravenous , Male , Propranolol/adverse effects , Reproducibility of Results , Verapamil/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...