Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Publication year range
1.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-993406

ABSTRACT

Objective:To evaluate the accuracy of the domestic "Skywalker" surgical robot in implementing personalized lower limb alignment reconstruction scheme in total knee arthroplasty (TKA) and the short-term clinical outcome of robotic assisted TKA.Methods:From September 2020 to January 2021, the data of patients who received surgical robot assisted TKA in 5 clinical centers in China (Shanghai Ninth People's Hospital affiliated to Shanghai Jiao Tong University School of Medicine, Southwest Hospital affiliated to Third Military Medical University, The Affiliated Hospital of Qingdao University, The First Affiliated Hospital of Chongqing Medical University and Yantai Yuhuangding Hospital, and Shanghai Ninth People's Hospital affiliated to Shanghai Jiao Tong University School of Medicine was the group leader) were prospectively collected and retrospectively analyzed. There were 24 males and 82 females with an average age of 67.6±7.3 years, (range 45-80 years); Average body mass index 26.42±4.31 kg/m 2, all the operation were performed by "Skywalker" surgical robot system according to preoperative design based on CT. The operation time, intraoperative blood loss, hospitalization days and postoperative complications were recorded, and the imaging indexes including hip-knee-ankle (HKA), lateral distal angle of femur (LDFA) and medial proximal angle of tibia (MPTA) measured before and after the operation, implant model indexes (preoperative planning implant model and postoperative implant model) and short-term clinical efficacy indexes [Western Ontario and McMaster Universities (WOMAC) osteoarthritis index] pain score, stiffness score, joint function score, total score and SF-12 score before and 3 months after the operation) were compared. Results:The average follow-up period was 109.60±9.80 d, (range 95-143 d). The average operation time of 106 patients was 105.30±23.22 min; The average intraoperative blood loss was 141.70±58.33 ml; The average length of hospitalization was 5.82±2.80 d. One patient had ischemic stroke after operation, and one patient had abnormal liver function after operation. According to the judgment of the investigator, all of them were not related to the operation. The actual angle error is the difference between the preoperative planning angle and the postoperative measurement angle. The absolute error of 99.1% (105/106) of the HKA angle was within 3°, 90.8% (69/76) of LDFA, 98.7% (75/76) of the MPTA. In 45 patients in one center where data were available, the actual implant models used in all patients were consistent with the preoperative planning size, and there were only differences in version selection such as Asian condyle. WOMAC pain score, joint function score, total score was improved from 7.34±2.85, 25.10±9.85, 34.75±13.02 to 3.34±2.66, 14.68±9.64, 18.66±13.49 before and after operation, respectively, which were statistically significant ( P<0.001) and SF-12 physiological score and psychological score were improved form 27.24±6.42, 30.68±8.26 to 38.83±5.74, 39.36±7.85 before and after operation, respectively, which were statistically significant ( t=7.33, P<0.001; t=4.53, P=0.043). Conclusion:Domestic surgical robot system "Skywalker" can assist the surgeon to achieve accurate and personalized reconstruction of lower limb alignment and achieve satisfactory short-term clinical outcomes. The long-term clinical outcomes of personalized reconstruction and survival rate of implant still need to be further studied.

2.
J Orthop Translat ; 19: 47-57, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31844613

ABSTRACT

Osteoporosis is a bone disease that is associated with a decrease in bone mineral density, deterioration of bone microarchitecture and increased fracture risk. Currently, available treatments mainly focus on either inhibiting osteoclast function, such as administration of bisphosphonate, calcitonin, oestrogen, selective oestrogen receptor modulator and so on, or stimulating osteoblasts, such as parathyroid hormone, to improve bone mass and skeletal microarchitecture. However, there is no option that is completely satisfactory because of the limitations of monotherapy with either class. Thus, it is highly appealing to investigate novel drugs with both antiresorptive and osteoanabolic activities that have the potential to be more beneficial than monotherapy because of the different mechanism of action. As has been proven in previous study that andrographolide (AP), as a key herbal medicine, could suppress osteoclast formation and function both in vivo and in vitro. The purpose of this present study was to identify the effect of AP on osteoblast differentiation and oestrogen deficiency-induced osteoporosis. It was concluded that AP significantly reduced oestrogen deficiency-induced bone loss in vivo. Furthermore, it was proved that tumor necrosis factor alpha severely impaired bone morphogenetic protein-2 (BMP-2)-induced osteoblast differentiation, and this inhibition could be greatly attenuated by AP. This was further supported by the fact that AP significantly increases the expression of osteoblast-specific markers, including runt-related transcription factor-2, osteocalcin and osteopontin. In addition, molecular analysis revealed that AP greatly ceased tumor necrosis factor alpha-mediated stimulation of nuclear factor kappa-Β activity, whereas overexpression of the nuclear factor kappa-Β subunit p65 reversed the stimulatory effects of AP on osteoblast differentiation. Thus, combined with previous study, AP was demonstrated to be a novel agent with both antiresorptive and osteoanabolic activities and had the potential to be developed as an antiosteoporosis alternative. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: This study provides strong evidence for the identification that AP has both antiresorptive and osteoanabolic activities and thus has great potential to be developed as a novel antiosteoporosis agent.

3.
Journal of Medical Biomechanics ; (6): E346-E351, 2019.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-802465

ABSTRACT

Objective Based on the principle of uncemented stem design, the femoral anteversion in different CT planes before total hip arthroplasty (THA) and stem anteversion after THA was compared, so as to find out the preoperative measurement to estimate stem anteversion in patients with developmental dysplasia of the hip(DDH) after THA. Methods Twenty-one primary THA patients (28 hips) who were diagnosed with DDH between September 2007 and May 2013 in Shanghai Ninth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine were selected. Preoperative and postoperative CT scans were performed on all patients. The femoral anteversion angle was defined as the angle between the midcortical line between the anterior and posterior cortical line in five CT slices and the posterior condylar axis. The slice levels for the 4 femoral sites were selected,including the area just distal to the femoral head, the center of the lesser trochanter,1 cm height above center of the lesser trochanter, 2 cm height above center of the lesser trochanter (marked as femoral anteversion 1-4). Femoral anteversion 5 was defined as the midcortical line of the anterior cortical line in the slice of 2 cm height above center of the lesser trochanter and the posterior cortical line in the slice of 50% of the distance from the top of greater trochanter to the center of the lesser trochanter above the center of the lesser trochanter. The stem anteversion angle was defined as the angle formed by the stem neck major axis and the posterior aspect of the femoral condylar line. The cup version and stem alignment were also calculated. The difference value and correlation coefficients of femoral anteversion 1-5 and stem anteversion were compared. Results Femoral anteversion 1-5 was 17.70°±10.54°, 35.59°±7.21°, 31.09°±7.98°, 24.71°±9.11°, 21.94°±10.10°, respectively。Stem anteversion was 20.52°±10.90°. The difference value between stem anteversion and femoral anteversion 1-5 was 2.82°±6.27°, -15.08°±7.99°, -13.80°±15.68°, -4.19°±5.69°, -1.42°±4.07°, respectively. Cup anteversion was 25.60°±11.65°, and combined antevertion was 46.11°±13.28°,sagittal stem tilt was 1.13°±1.53°. There were statistically significant differences between femoral anteversion 1-4 and stem anteversion (P<0.05), and no statistical difference was found between femoral anteversion 5 and stem anteversion. The correlation coefficients of femoral anteversion 1-5 and stem anteversion were 0.829, 0.681, 0.689, 0.853, 0.928, respectively. Conclusions Femoral anteversion 5 had a highly positive correlation with stem anteversion, which was an effective a substitute of stem anteversion before THA.

4.
Journal of Medical Biomechanics ; (6): E346-E351, 2019.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-802362

ABSTRACT

Objective Based on the principle of uncemented stem design, the femoral anteversion in different CT planes before total hip arthroplasty (THA) and stem anteversion after THA was compared, so as to find out the preoperative measurement to estimate stem anteversion in patients with developmental dysplasia of the hip(DDH) after THA. Methods Twenty-one primary THA patients (28 hips) who were diagnosed with DDH between September 2007 and May 2013 in Shanghai Ninth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine were selected. Preoperative and postoperative CT scans were performed on all patients. The femoral anteversion angle was defined as the angle between the midcortical line between the anterior and posterior cortical line in five CT slices and the posterior condylar axis. The slice levels for the 4 femoral sites were selected,including the area just distal to the femoral head, the center of the lesser trochanter,1 cm height above center of the lesser trochanter, 2 cm height above center of the lesser trochanter (marked as femoral anteversion 1-4). Femoral anteversion 5 was defined as the midcortical line of the anterior cortical line in the slice of 2 cm height above center of the lesser trochanter and the posterior cortical line in the slice of 50% of the distance from the top of greater trochanter to the center of the lesser trochanter above the center of the lesser trochanter. The stem anteversion angle was defined as the angle formed by the stem neck major axis and the posterior aspect of the femoral condylar line. The cup version and stem alignment were also calculated. The difference value and correlation coefficients of femoral anteversion 1-5 and stem anteversion were compared. Results Femoral anteversion 1-5 was 17.70°±10.54°, 35.59°±7.21°, 31.09°±7.98°, 24.71°±9.11°, 21.94°±10.10°, respectively。Stem anteversion was 20.52°±10.90°. The difference value between stem anteversion and femoral anteversion 1-5 was 2.82°±6.27°, -15.08°±7.99°, -13.80°±15.68°, -4.19°±5.69°, -1.42°±4.07°, respectively. Cup anteversion was 25.60°±11.65°, and combined antevertion was 46.11°±13.28°,sagittal stem tilt was 1.13°±1.53°. There were statistically significant differences between femoral anteversion 1-4 and stem anteversion (P<0.05), and no statistical difference was found between femoral anteversion 5 and stem anteversion. The correlation coefficients of femoral anteversion 1-5 and stem anteversion were 0.829, 0.681, 0.689, 0.853, 0.928, respectively. Conclusions Femoral anteversion 5 had a highly positive correlation with stem anteversion, which was an effective a substitute of stem anteversion before THA.

5.
J Orthop Translat ; 14: 57-62, 2018 Jul.
Article in English | MEDLINE | ID: mdl-30035033

ABSTRACT

BACKGROUND: Surgical masks (SMs) are used to reduce bacterial shedding from the mouth, nose and face. This study aimed to investigate whether SMs may be a potential source of bacterial shedding leading to an increased risk of surgical site infection. METHODS: Bacterial contamination of the SMs was tested by making an impression of the external surface of the mask on sterile culture media immediately. We investigated the difference in bacterial counts between the SMs worn by surgeons and those placed unused in the operating room (OR), and the bacterial count variation with indicated wearing time. Moreover, the difference in bacterial counts on the external surface between the first and second layers of double-layered SMs was also assessed. RESULTS: The bacterial count on the surface of SMs increased with extended operating times; significant difference was found between the 4- to 6-hour and 0-hour groups (p < 0.05). When we analysed the bacterial counts from the same surgeon, a significant increase was noted in the 2-hours group. Moreover, the bacterial counts were significantly higher among the surgeons than the OR. Additionally, the bacterial count of the external surface of the second mask was significantly higher than that of the first one. CONCLUSIONS: The source of bacterial contamination in SMs was the body surface of the surgeons rather than the OR environment. Moreover, we recommend that surgeons should change the mask after each operation, especially those beyond 2 hours. Double-layered SMs or those with excellent filtration function may also be a better alternative. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: This study provides strong evidence for the identification that SMs as source of bacterial contamination during operative procedures, which should be a cause for alarm and attention in the prevention of surgical site infection in clinical practice.

SELECTION OF CITATIONS
SEARCH DETAIL
...