Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 89
Filter
1.
J Orthop Surg Res ; 18(1): 219, 2023 Mar 20.
Article in English | MEDLINE | ID: mdl-36941623

ABSTRACT

BACKGROUND: This study aimed to estimate the ratio of the anterior and posterior gaps before surgery that can minimize the posterior tibial slope (PTS) change through preoperative radiography, and to confirm whether the use of the block helps maintain the PTS during open wedge high tibial osteotomy (OWHTO). METHODS: Patients who underwent OWHTO between 2015 and 2018 were included. To measure optimal anterior gap (AG) and posterior gap (PG) ratio, hinge to medial tibial tuberosity length (HTL), total osteotomy length (TOL), and PTS were measured using knee AP X-ray. Real AG and PG were measured using postoperative knee computed tomography. Use of the block was also confirmed. RESULTS: Total 107 knees (95 patients) were included. The average ratio between HTL and TOL was 70.9%. The average ratio AG: PG was 72.9%. PTS increased significantly from 10.2° to 11.2° postoperatively (p = 0.006). When the difference in HTL: TOL and AG: PG, and the amount of PTS change were analyzed using linear regression, there was a statistically significant correlation (correlation coefficient: - 25.9; p < 0.001). There was no difference in AG: PG according to the use of the block (p = 0.882). CONCLUSION: In OWHTO, PTS change can be minimized by estimating the ratio of the AG and PG using radiographs, and is was approximately 70%. If the ratio is increased by 10% from the predicted value, the PTS increases by approximately 2.6°. Using a block during OWHTO did not have a considerable advantage in terms of PTS maintenance compared to the group not using a block. LEVEL OF EVIDENCE: Level IV.


Subject(s)
Osteoarthritis, Knee , Humans , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery , Radiography , Tibia/diagnostic imaging , Tibia/surgery , Knee Joint/diagnostic imaging , Knee Joint/surgery , Osteotomy/methods , Retrospective Studies
2.
Knee Surg Relat Res ; 35(1): 6, 2023 Feb 14.
Article in English | MEDLINE | ID: mdl-36788629

ABSTRACT

PURPOSE: The purpose of this systematic review was to determine the effect of Parkinson's disease (PD) on clinical outcomes and complications after total knee arthroplasty (TKA). Our systematic review was conducted to answer the following questions: (1) does TKA negatively affect clinical outcomes in patients with PD? and (2) does TKA cause more complications in patients with PD? METHODS: A rigorous and systematic approach was used, and each selected study was evaluated for methodological quality. Data on study design, total number of cases enrolled, follow-up duration, PD severity, clinical outcome, and complications after TKA were analyzed. RESULTS: Fourteen studies were included. Nine studies reported clinical scores. TKA significantly increased knee and functional scores in the PD group. However, compared with knee and functional scores in the non-PD group, the increase in scores in the PD group was not statistically significant, but tended to be less than that in the non-PD group. Eleven studies reported complications. In six studies, there was no difference in the complication rate between the PD and non-PD group or did not include a control group. In five studies, the PD group had higher medical complication rates and similar or higher surgical complication rates than the non-PD group. CONCLUSIONS: Patients with PD who underwent TKA showed satisfactory functional improvement and pain reduction. However, these outcomes were not as good as those in the non-PD group. The PD group had a higher probability of occurrence of medical complications than the non-PD group. Further, the PD group had a similar or higher surgical complication rate than the non-PD group.

3.
Knee Surg Relat Res ; 34(1): 6, 2022 Feb 19.
Article in English | MEDLINE | ID: mdl-35183256

ABSTRACT

PURPOSE: The quadriceps muscle has a positive effect on anterior knee pain. However, its effect on the patellofemoral (PF) cartilage in patients with end-stage knee osteoarthritis is unknown. The present study aimed to evaluate whether the quadriceps muscle area had a positive effect on the PF cartilage and whether this muscle had a positive effect on the clinical scores. MATERIALS AND METHODS: Patients with confirmed cartilage status and clinical scores who underwent total knee arthroplasty (TKA) were included. The PF cartilage status was evaluated during TKA. The thickness and the area of the quadriceps muscle were measured using a knee computed tomography scan obtained before the surgery. The Q-angle, hip-knee-ankle angle, alignment, and Insall-Salvati ratio were measured by radiography. RESULTS: Altogether, 204 patients were included in the study. Logistic regression was performed including factors associated with PF cartilage lesions. The regression model was found to be statistically significant (Hosmer-Lemeshow test, χ2 = 0.493). A smaller hip-knee-ankle (HKA) angle was associated with a higher incidence of PF cartilage lesions (p = 0.033) and only the alignment had an effect on the PF cartilage lesions. PF cartilage lesions did not correlate with the clinical scores. A thicker medial portion of the quadriceps muscle was associated with a significantly higher Knee Society Knee Score (KSKS) (p = 0.028). CONCLUSIONS: Quadriceps muscle thickness and area, Q-angle, and patellar height were not associated with PF cartilage lesions, while a smaller HKA angle was associated with PF cartilage lesions. The presence of PF cartilage lesions did not affect the clinical symptoms. However, a thicker medial portion of the quadriceps muscle was associated with a higher KSKS.

4.
Arch Orthop Trauma Surg ; 142(9): 2335-2348, 2022 Sep.
Article in English | MEDLINE | ID: mdl-34462825

ABSTRACT

PURPOSE: This study aims to investigate the incidence rate and risk factors of stroke in patients treated with bilateral TKA compared with patients with unilateral TKA. METHODS: In this retrospective nationwide cohort study, we compared patients undergoing unilateral TKA or bilateral TKA using data from the Korean National Health Insurance claims database between January 1, 2009 and August 31, 2017 and included patients older than 40 years of age who underwent primary TKA by the index date as documented primary diagnosis and first additional diagnosis without a history of stroke during the preceding 1 year. We used matched Cox regression models to compare the incidence rate and risk factors of newly acquired stroke among patients treated with unilateral TKA or bilateral TKA after propensity score (PS) matching. RESULTS: In the present study, 163,719 patients who received unilateral TKA were matched to 163,719 patients with bilateral TKA based on PS. The risk of stroke during the study period was lower in patients treated with bilateral TKA than in patients with unilateral TKA (adjusted hazard ratio [HR] 0.79). Patients who received bilateral TKA were at decreased risk of stroke when the following variables were present: advanced age (70-79 years, HR 0.76), female sex (HR 0.75), rural area (HR 0.77), small- or medium-sized hospital (HR 0.75), health insurance (HR 0.77), history of hypertension drug use (HR 0.75), congestive heart failure (HR 0.70), connective tissue disease (HR 0.71), diabetes (HR 0.77), and diabetes with complication (HR 0.76). CONCLUSION: The risk of stroke was lower in patients treated with bilateral TKA than in patients with unilateral TKA. Patients treated with bilateral TKA were at decreased risk of stroke when the following variables were present: age (70-79 years), female sex, health insurance, history of hypertension drug use, and comorbidities, such as congestive heart failure, connective tissue disease, and diabetes.


Subject(s)
Arthroplasty, Replacement, Knee , Heart Failure , Hypertension , Stroke , Aged , Arthroplasty, Replacement, Knee/adverse effects , Cohort Studies , Female , Heart Failure/epidemiology , Humans , Hypertension/etiology , National Health Programs , Retrospective Studies , Stroke/epidemiology , Stroke/etiology , Treatment Outcome
5.
Orthop J Sports Med ; 9(1): 2325967120973052, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33490296

ABSTRACT

BACKGROUND: There is currently no optimal method for cartilage restoration in large, full-thickness cartilage defects in older patients. PURPOSE: To determine whether implantation of a composite of allogeneic umbilical cord blood-derived mesenchymal stem cells and 4% hyaluronate (UCB-MSC-HA) will result in reliable cartilage restoration in patients with large, full-thickness cartilage defects and whether any clinical improvements can be maintained up to 5 years postoperatively. STUDY DESIGN: Randomized controlled trial; Level of evidence, 1. METHODS: A randomized controlled phase 3 clinical trial was conducted for 48 weeks, and the participants then underwent extended 5-year observational follow-up. Enrolled were patients with large, full-thickness cartilage defects (International Cartilage Repair Society [ICRS] grade 4) in a single compartment of the knee joint, as confirmed by arthroscopy. The defect was treated either with UCB-MSC-HA implantation through mini-arthrotomy or with microfracture. The primary outcome was proportion of participants who improved by ≥1 grade on the ICRS Macroscopic Cartilage Repair Assessment (blinded evaluation) at 48-week arthroscopy. Secondary outcomes included histologic assessment; changes in pain visual analog scale (VAS) score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and International Knee Documentation Committee (IKDC) score from baseline; and adverse events. RESULTS: Among 114 randomized participants (mean age, 55.9 years; 67% female; body mass index, 26.2 kg/m2), 89 completed the phase 3 clinical trial and 73 were enrolled in the 5-year follow-up study. The mean defect size was 4.9 cm2 in the UCB-MSC-HA group and 4.0 cm2 in the microfracture group (P = .051). At 48 weeks, improvement by ≥1 ICRS grade was seen in 97.7% of the UCB-MSC-HA group versus 71.7% of the microfracture group (P = .001); the overall histologic assessment score was also superior in the UCB-MSC-HA group (P = .036). Improvement in VAS pain, WOMAC, and IKDC scores were not significantly different between the groups at 48 weeks, however the clinical results were significantly better in the UCB-MSC-HA group at 3- to 5-year follow-up (P < .05). There were no differences between the groups in adverse events. CONCLUSION: In older patients with symptomatic, large, full-thickness cartilage defects with or without osteoarthritis, UCB-MSC-HA implantation resulted in improved cartilage grade at second-look arthroscopy and provided more improvement in pain and function up to 5 years compared with microfracture. REGISTRATION: NCT01041001, NCT01626677 (ClinicalTrials.gov identifier).

6.
Knee Surg Sports Traumatol Arthrosc ; 29(4): 1098-1105, 2021 Apr.
Article in English | MEDLINE | ID: mdl-32556436

ABSTRACT

PURPOSE: To evaluate the rotational profile of the lower extremity using computed tomography (CT) in accordance with the degree of varus deformity in medial condyle-affected knee joint osteoarthritis (OA). METHODS: This retrospective study included 1036 patients (872 lower extremities) with end-stage knee OA. The coronal alignment of the lower extremity was measured using standing anteroposterior radiography. The CT parameters of femoral anteversion and tibial torsion were assessed in relation to the knee joint. The axes were the femoral neck axis; the distal femoral axis, which was composed of the anterior trochlear axis, the clinical transepicondylar axis, and the posterior condylar axis; the axis of the proximal tibial condyles; and the bimalleolar axis. RESULTS: There was a tendency for increased external rotation of the knee joint parameters in relation to the hip and ankle joints as varus deformity of the lower extremity increased. The relative external rotational deformity of the knee joint in relation to the hip joint had a positive value with a good correlation. The relative external rotational deformity of the knee joint in relation to the ankle joint also demonstrated a positive value with a good correlation. CONCLUSION: The distal femur and proximal tibia (knee joint) tended to rotate externally in relation to the hip and ankle joint, respectively, as the degree of varus deformity increased. This study identified the relationship between lower extremity varus deformity and rotational deformity of knee joints with OA. LEVEL OF EVIDENCE: III.


Subject(s)
Genu Varum/pathology , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/physiopathology , Aged , Ankle Joint/physiopathology , Arthroplasty, Replacement, Knee/methods , Female , Femur/physiopathology , Femur Neck/physiopathology , Genu Varum/diagnostic imaging , Hip Joint/physiopathology , Humans , Knee Joint/physiopathology , Lower Extremity/diagnostic imaging , Lower Extremity/physiopathology , Male , Osteoarthritis, Knee/surgery , Radiography/methods , Range of Motion, Articular , Retrospective Studies , Rotation , Tibia/physiopathology , Tomography, X-Ray Computed/methods
7.
J Knee Surg ; 34(2): 216-223, 2021 Jan.
Article in English | MEDLINE | ID: mdl-31378861

ABSTRACT

This work was designed to compare the intraoperative parameters and clinical and radiologic outcomes of total knee arthroplasty (TKA) during a minimum follow-up period of 2 years and to discuss the pros and cons of two different tracker placement (diaphyseal and metaphyseal) navigation systems. The null hypothesis was that there would be no clinical or radiologic difference between the two different systems. Primary TKA was performed in a total of 100 knees using the two different image-free navigation systems (group 1: diaphyseal tracker placement and group 2: metaphyseal tracker placement) with the strict gap balancing technique. Symptom severity was assessed at preoperative and at 3, 6, 12, and 24 months after surgery using the Knee Society Score (KSS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score. Possible adverse issues (major and minor) associated with TKA procedure were observed. Careful assessments were also made of the screw insertion site for infection, stress fractures, and any other related adverse effects. The follow-up periods for groups 1 and 2 were 38 ± 8 months and 38 ± 7 months, respectively. The minimum follow-up period was 24 months. The mechanical alignment improved to 0.1 (valgus) ± 2.2 (group 1) and 0.2 (valgus) ± 2.1 (group 2). There were no radiologic differences between the groups (p > 0.05). In both groups, the KSS and WOMAC improved from before surgery to 24 months after surgery (p < 0.0001). However, the total operation time was 50 ± 5 minutes for group 1, compared to 65 ± 13 minutes for group 2 (p < 0.0001). The metaphyseal tracker navigation system resulted in increased operation time.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Osteoarthritis, Knee/surgery , Surgery, Computer-Assisted/methods , Aged , Arthroplasty, Replacement, Knee/instrumentation , Female , Femur/surgery , Humans , Knee Joint/surgery , Knee Prosthesis , Male , Middle Aged , Prospective Studies , Retrospective Studies , Stereotaxic Techniques , Surgery, Computer-Assisted/instrumentation , Surgical Navigation Systems , Tibia/surgery
9.
Indian J Orthop ; 53(5): 622-629, 2019.
Article in English | MEDLINE | ID: mdl-31488931

ABSTRACT

BACKGROUND: Nutrient artery canals of the femur are often visible on plain radiographs as radiolucent lines which may mimic fracture lines. The purpose of this study was to distinguish nutrient artery canals from fracture lines on plain radiographs. MATERIALS AND METHODS: Ninety-three patients (102 hips) with an average age of 65.6 years were included in the study. We retrospectively analyzed nutrient artery canals of the femur on pre and postoperative anteroposterior (AP) and cross-table lateral (CTL) hip radiographs in patients with cementless total hip arthroplasty. The shape, number, location, direction of obliquity, length of nutrient artery canal, and the distance between the tip of the greater trochanter and the proximal end of the nutrient artery canal were measured. RESULTS: Nutrient artery canals were determined in 54 hips (53.0%) on preoperative radiographs. The numbers of nutrient artery canals were entirely found to be one for each hip. The nutrient artery canals of the femur were the most frequently seen in the cortex on CTL radiographs with 32 hips (31.4%), whereas nutrient artery canals were not seen at all in the cortex on AP radiographs. All nutrient artery canals in the cortex on CTL radiographs coursed upward obliquely. Comparing to fracture lines, nutrient artery canals show less radiolucency, smaller diameter, and blunted ends in both the cortex and medullary cavity, show sclerotic walls in the cortex and have the less straight course in the medullary cavity. CONCLUSIONS: Based on the results of this study, there are clearly distinguishable differences between nutrient artery canals of the femur and fracture lines on plain radiographs.

10.
J Bone Joint Surg Am ; 101(9): 771-778, 2019 May 01.
Article in English | MEDLINE | ID: mdl-31045664

ABSTRACT

BACKGROUND: High tibial osteotomy (HTO) is often performed to postpone or avoid the need for subsequent total knee arthroplasty (TKA). We designed the present study to investigate the incidence rate and risk factors for subsequent revision in patients treated with HTO compared with those managed with TKA. METHODS: In this retrospective nationwide cohort study, we reviewed the South Korean National Health Insurance claims database from January 1, 2009, to August 31, 2017. We evaluated patients ≥41 years old who had undergone TKA or HTO as the primary surgical procedure without a history of having undergone either procedure during the preceding 2 years. By including only new interventions without such prior surgery, we could eliminate the influence of previous TKA and HTO treatments. Multivariable logistic regression models were used to compare the risk of revision between the groups after propensity score matching with inverse probability of treatment weighting (IPTW). Revision was defined as conversion to revision TKA after primary TKA and conversion to TKA after HTO. RESULTS: After applying the IPTW, a total of 436,538 patients with TKA and 452,724 patients with HTO were identified. The risk of revision during the entire study period was higher for patients with HTO than for patients with TKA (adjusted hazard ratio [HR], 2.47). The Kaplan-Meier 8-year survival was 97.8% in the TKA group and 91.5% in the HTO group. Compared with patients with TKA, patients with HTO had an increased risk of revision in cases of advanced age (HR of 1.85 for patients who were ≥61 to 69 years old and HR of 4.17 for those who were ≥70 years old), female sex (HR, 2.90), recipients of Medical Aid program benefits (HR, 4.77), the presence of hyperlipidemia (HR, 3.70), the presence of diabetes (HR, 4.86), and the presence of osteoporosis (HR, 3.53). However, younger patients with HTO (≤60 years old) had a lower risk of subsequent revision (HR, 0.64). CONCLUSIONS: The risk of revision was higher for patients with HTO than for patients with TKA. The risk factors for subsequent revision in patients with HTO in our cohort of patients were advanced age (>60 years), female sex, receipt of Medical Aid, and the presence of comorbidities, such as diabetes, osteoporosis, and hyperlipidemia. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Osteoarthritis, Knee/surgery , Osteotomy/adverse effects , Postoperative Complications/epidemiology , Reoperation , Tibia/surgery , Adult , Aged , Female , Humans , Incidence , Male , Middle Aged , Osteoarthritis, Knee/complications , Postoperative Complications/surgery , Propensity Score , Republic of Korea , Retrospective Studies , Risk Factors , Treatment Outcome
11.
PLoS One ; 14(4): e0216004, 2019.
Article in English | MEDLINE | ID: mdl-30998776

ABSTRACT

[This corrects the article DOI: 10.1371/journal.pone.0214279.].

12.
PLoS One ; 14(3): e0214279, 2019.
Article in English | MEDLINE | ID: mdl-30908538

ABSTRACT

There is debate in the literature whether rotating hinge knee (RHK) or constrained condylar knee (CCK) prostheses lead to better clinical outcomes and survival rates in patients undergoing revision total knee arthroplasty (RTKA). The purpose of this meta-analysis is to compare the survivorship and clinical outcomes of RHK and CCK prostheses. In this meta-analysis, we reviewed studies that evaluated pain and function scores, range of motion (ROM), complications, and survival rates in patients treated with RHK or CCK with short-term (<5 years) or midterm (5-10 years) follow-up. The survivorship was considered as the time to additional surgical intervention such as removal or revision of the components. A total of 12 studies (one randomized study and 11 non-randomized studies) met the inclusion criteria and were analyzed in detail. The proportion of the knees in which short-term (<5 years) survival rates (RHK, 83/95; CCK, 111/148; odds ratio [OR] 0.52; 95% CI, 0.24-1.11; P = 0.09) and midterm (5-10 years) survival rates (RHK, 104/128; CCK, 196/234; OR 1.05; 95% CI, 0.56-1.97; P = 0.88) were evaluated did not differ significantly between RHK and CCK prostheses. In addition, there were no significant differences in ROM (95% CI: -0.40 to 9.93; P = 0.07) and complication rates (95% CI: 0.66 to 2.49; P = 0.46). In contrast, CCK groups reported significantly better pain score (95% CI: 0.50 to 2.73; P = 0.005) and function score (95% CI: 0.01 to 2.00; P = 0.05) than RHK groups. This meta-analysis revealed that 87.4% of RHK and 75.0% of CCK prostheses survive at short-term (<5 years), while 81.3% of RHK and 83.8% of CCK prostheses survive at midterm (5-10 years). The differences in standardized mean pain and function scores we detected were likely to be imperceptible to patients and almost certainly below the minimum clinically important level, despite a significant difference in both groups. Based on the findings of the current meta-analysis, RHK prostheses continue to be an option in complex RTKA with reasonable midterm survivorship.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Knee Joint/surgery , Knee Prosthesis , Prosthesis Failure , Biomechanical Phenomena , Female , Humans , Male , Pain Measurement , Prosthesis Design , Range of Motion, Articular , Reoperation , Treatment Outcome
13.
Ann Rehabil Med ; 42(5): 773-776, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30404427

ABSTRACT

Spinal accessory nerve (SAN) injury mostly occurs during surgical procedures. SAN injury caused by manipulation therapy has been rarely reported. We present a rare case of SAN injury associated with manipulation therapy showing scapular winging and droopy shoulder. A 42-year-old woman visited our outpatient clinic complaining of pain and limited active range of motion (ROM) in right shoulder and scapular winging after manipulation therapy. Needle electromyography and nerve conduction study suggested SAN injury. Physical therapy (PT) three times a week for 2 weeks were prescribed. After a total of 6 sessions of PT and modality, the patient reported that the pain was gradually relieved during shoulder flexion and abduction with improved active ROM of shoulder. Over the course of 2 months follow-up, the patient reported almost recovered shoulder ROM and strength as before. She did not complain of shoulder pain any more.

14.
Knee Surg Relat Res ; 30(4): 273-274, 2018 Dec 01.
Article in English | MEDLINE | ID: mdl-30466248
15.
Indian J Orthop ; 52(4): 434-437, 2018.
Article in English | MEDLINE | ID: mdl-30078905

ABSTRACT

The cases of revision total knee arthroplasty (TKA) are increasing. In this report, snapping phenomenon after final implantation of revision TKA has been presented. Snapping was caused by adhered iliotibial band (ITB) impinging against the lateral part of femoral component. Fractional lengthening the ITB by puncture resolved the snapping phenomenon. Surgeons should be aware of the presence of such a case which should be identified during operation to avoid secondary operations.

16.
Knee Surg Relat Res ; 30(3): 206-214, 2018 Sep 01.
Article in English | MEDLINE | ID: mdl-29983008

ABSTRACT

PURPOSE: Bone marrow (BM) is frequently used as a source of mesenchymal stem cells (MSCs) because they have a high potential for differentiation. However, it is unclear whether BM-derived MSCs lead to better clinical and magnetic resonance imaging (MRI) outcomes postoperatively. MATERIALS AND METHODS: This meta-analysis compared the clinical and MRI outcomes in patients with knee osteoarthritis (OA) treated with BM-derived MSCs. Eight studies comparing the clinical and MRI outcomes assessed with various measurement tools in patients with knee OA treated with BM-derived MSCs were included. RESULTS: The range of motion (95% confidence interval [CI], -13.05 to 4.24; p=0.32) and MRI outcomes (95% CI, -0.16 to 1.40; p=0.12) did not differ significantly between the baseline and final follow-up. In contrast, pain (95% CI, 0.89 to 1.87; p<0.001) and functional outcomes (95% CI, 0.70 to 2.07; p<0.001) were significantly improved at the final follow-up when compared to the baseline. CONCLUSIONS: This meta-analysis found no significant difference in the tested range of motion and MRI outcomes between the baseline and the final follow-up in patients treated with BM-derived MSCs, whereas significant functional improvement and pain relief were noted when compared with the baseline. Thus, BM-derived MSCs appear to be a viable alternative for patients with knee OA, although long-term and high-quality randomized controlled trials are needed to confirm the clinical benefits.

17.
Ann Rehabil Med ; 42(2): 260-269, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29765879

ABSTRACT

OBJECTIVE: To investigate the utility of ultrasonography to objectively examine morphological changes (i.e., muscle atrophy and fatty infiltration) of the supraspinatus muscle. METHODS: Thirty-four patients were prospectively enrolled in this study. The degrees of muscle atrophy and fat infiltration were measured using ultrasonography 3-4 months after arthroscopic supraspinatus tendon repair. Shoulder function (i.e., shoulder active range of motion, visual analogue scale, and constant score) was examined. Using the symmetricity of the muscles in the human body, the degrees of morphological changes of the supraspinatus muscle were quantitatively measured. The associations between the morphological changes of the supraspinatus muscle and shoulder function were identified. RESULTS: There were statistically significant differences in the cross-sectional area (CSA) and echogenicity between the surgery and non-surgery sides (p<0.001). The CSA ratio, which represents the degree of muscle atrophy, was associated with shoulder forward flexion, external rotation, and constant score; however, the echogenicity ratio, which represents the degree of fat infiltration, was not associated with shoulder function after surgery. CONCLUSION: This study demonstrated that shoulder function could be predicted by evaluating the morphological changes of the supraspinatus muscle using ultrasonography and that objective evaluation is possible through quantitative measurement using the symmetricity of the human body.

18.
Ann Rehabil Med ; 42(2): 321-328, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29765886

ABSTRACT

OBJECTIVE: To determine the optimal stimulation and recording site for infrapatellar branch of saphenous nerve (IPBSN) conduction studies by a cadaveric study, and to confirm that obtained location is practically applicable to healthy adults. METHODS: Twelve lower limbs from six cadavers were studied. We defined the optimal stimulation site as the point IPBSN exits the sartorius muscle and the distance or ratio were measured on the X- and Y-axis based on the line connecting the medial and lateral poles of the patella. We defined the optimal recording site as the point where the terminal branch met the line connecting inferior pole of patella and tibial tuberosity, and measured the distance from the inferior pole. Also, nerve conduction studies were performed with obtained location in healthy adults. RESULTS: In optimal stimulation site, the mean value of X-coordinate was 55.50±6.10 mm, and the ratio of the Y-coordinate to the thigh length was 25.53%±5.40%. The optimal recording site was located 15.92±1.83 mm below the inferior pole of patella. In our sensory nerve conduction studies through this location, mean peak latency was 4.11±0.30 ms and mean amplitude was 4.16±1.49 µV. CONCLUSION: The optimal stimulation site was located 5.0-6.0 cm medial to medial pole of the patella and 25% of thigh length proximal to the X-axis. The optimal recording site was located 1.5-2.0 cm below inferior pole of patella. We have also confirmed that this location is clinically applicable.

19.
Medicine (Baltimore) ; 97(17): e0558, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29703041

ABSTRACT

BACKGROUND: Although many factors are known to influence the polymerization time of bone cement, it remains unclear which bone cement shape predicts the precise polymerization time. The purpose of this study was to investigate whether different cement shapes influenced polymerization time and to identify the relationship between cement shape and ambient operating theater temperature, relative humidity, and equilibration time. METHODS: Samples were gathered prospectively from 237 patients undergoing primary total knee arthroplasty. The cement components were made into 2 different shapes: lump and pan. The time at which no macroscopic indentation of both cement models was possible was recorded as the polymerization time. RESULTS: There was no significant difference between hand mixing (lump shape: 789.3 ±â€Š128.4 seconds, P = .591; pan shape: 899.3 ±â€Š152.2 seconds, P = .584) and vacuum mixing (lump shape: 780.2 ±â€Š131.1 seconds, P = .591; pan shape: 909.9 ±â€Š143.3 seconds, P = .584) in terms of polymerization time. Conversely, the polymerization time was significantly shorter for Antibiotic Simplex (lump shape: 757.4 ±â€Š114.9 seconds, P = .001; pan shape: 879.5 ±â€Š125.0 seconds, P < .001) when compared with Palacos R+G (lump shape: 829.0 ±â€Š139.3 seconds, P = .001; pan shape: 942.9 ±â€Š172.0 seconds, P < .001). Polymerization time was also significantly longer (P < .001) for the pan shape model (904 ±â€Š148.0 seconds) when compared with the lump shape model (785.2 ±â€Š129.4 seconds). In addition, the polymerization time decreased with increasing temperature (lump shape: R = 0.334, P < .001; pan shape: R = 0.375, P < .001), humidity (lump shape: R = 0.091, P < .001; pan shape: R = 0.106, P < .001), and equilibration time (lump shape: R = 0.073, P < .001; pan shape: R = 0.044, P < .001). CONCLUSIONS: The polymerization time was equally affected by temperature, relative humidity, and equilibration time regardless of bone cement shape. Furthermore, the pan shape model better reflected the cement polymerization time between implant and bone compared with the lump shape model. The current findings suggest that, clinically, constant pressure with the knee in <45° of flexion needs to be applied until remaining pan shaped cement is completely polymerized.


Subject(s)
Arthroplasty, Replacement, Knee/methods , Bone Cements/chemistry , Drug Compounding/methods , Polymerization , Humans , Prospective Studies , Temperature , Time Factors , Treatment Outcome
20.
Int Orthop ; 42(11): 2583-2589, 2018 11.
Article in English | MEDLINE | ID: mdl-29556754

ABSTRACT

BACKGROUND: The purpose of this retrospective study was to analyze and compare the clinical and radiologic outcomes of fixed bearing ultracongruent (UC) insert total knee arthroplasty (TKA) and mobile bearing (MB) floating platform TKA using the navigation-assisted gap balancing technique with a minimum follow-up of five years. METHODS: The study retrospectively enrolled 105 patients who received the UC type fixed bearing insert (group 1) and 95 patients who received the floating platform MB insert (group 2) during the period from August 2009 to June 2012. All surgery was performed using the navigation-assisted gap balancing technique. For strict assessment of gap measurements, the offset-type-force-controlled-spreader-system was used. Radiologic and clinical outcomes were assessed before operation and at the most recent follow-up using the Knee Society Score (KSS) and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score. For statistical analysis, paired sample t tests were used. A p value less than 0.05 was considered significant. RESULTS: Although the radiologic alignments were satisfactory for both groups (99/105 [94%] cases were neutral for group 1 and 90/95 [94%] for group 2), the functional and total WOMAC scores were inferior in group 2 (p < 0.05). There were two cases of insert breakage in group 2 that required bearing exchange. The Kaplan-Meier survivorship rates for groups 1 and 2 at 77 months were 100.0 and 97.9%, respectively. CONCLUSION: Second-generation MB floating platform TKA cases did not have satisfactory outcomes. There were two cases of insert breakage, which required bearing exchange. Other patients who underwent surgery with second-generation MB floating platform were encouraged to avoid high knee flexion activities, resulting in lower clinical performance.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Knee Prosthesis/adverse effects , Osteoarthritis, Knee/surgery , Prosthesis Design/adverse effects , Surgery, Computer-Assisted/adverse effects , Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee/instrumentation , Arthroplasty, Replacement, Knee/methods , Female , Follow-Up Studies , Humans , Knee Joint/surgery , Male , Middle Aged , Range of Motion, Articular , Retrospective Studies , Surgery, Computer-Assisted/instrumentation , Surgery, Computer-Assisted/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...