Radiol Phys Technol ; 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38888821

ABSTRACT

In positron emission tomography (PET), measurements of depth-of-interaction (DOI) information and time-of-flight (TOF) information are important. DOI information reduces the parallax error, and TOF information reduces noise by measuring the arrival time difference of the annihilation photons. Historically, these have been studied independently, and there has been less implementation of both DOI and TOF capabilities because previous DOI detectors did not have good TOF resolution. However, recent improvements in PET detector performance have resulted in commercial PET scanners achieving a coincidence resolving time of around 200 ps, which result in an effect even for small objects. This means that TOF information can now be utilized even for a brain PET scanner, which also requires DOI information. Therefore, various methods have been proposed to obtain better DOI and TOF information. In addition, the cost of PET detectors is also an important factor to consider, since several hundred detectors are used per PET scanner. In this paper, we review the latest DOI-TOF detectors including the history of detector development. When put into practical use, these DOI-TOF detectors are expected to contribute to the improvement of imaging performance in brain PET scanners.

2.
Phys Med Biol ; 69(12)2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38815615

ABSTRACT

Objective. Time-of-flight (TOF) is an important factor that directly affects the image quality of PET systems, and various attempts have been made to improve the coincidence resolving time (CRT) of PET detectors. For independent readout detectors, the timing is acquired for each silicon photomultiplier (SiPM), so they are less sensitive to diffused scintillation light, resulting in a better CRT. Further improvement can be expected if the light can be focused on a single SiPM. However, existing SiPM arrays have a thin protective cover on the SiPM and the gap between the SiPMs is filled with either air or the protective cover, so the light must diffuse through the cover. In this work, we investigated optical crosstalk in the protective cover to improve the CRT.Approach. We used 3.1 × 3.1 × 20 mm3fast LGSO crystals and 3 mm square 8 × 8 multi pixel photon counter (MPPC) arrays. Pitch of the MPPCs was 3.2 mm and thickness of the protective cover on them was 150µm. To reduce diffusion of scintillation light in the protective cover, the part of the inactive areas on the MPPC array were optically separated using reflective material. Specifically, 50, 100, 150, and 350µm deep grid-shaped slits were made along the inactive area of the MPPCs and they were filled with BaSO4powder as the reflective material.Main results. Coincidence counts were measured with a pair of TOF detectors, and the CRT was shorter with a deeper slit depth. The CRT before improvement was 235 ps, and using the cover having the 350µm deep slits filled with reflective material lowered the CRT to 211 ps.Significance. Up to 10% of the scintillation light was diffused to other MPPCs by the protective cover, and the CRT was degraded by 10% due to optical crosstalk of the cover. The proposed method promises to improve the CRT of the TOF detector.


Subject(s)
Positron-Emission Tomography , Positron-Emission Tomography/instrumentation , Optical Phenomena , Scintillation Counting/instrumentation , Time Factors , Photons
3.
Phys Med Biol ; 69(12)2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38776943

ABSTRACT

Objective.To compare the accuracy with which different hadronic inelastic physics models across ten Geant4 Monte Carlo simulation toolkit versions can predict positron-emitting fragments produced along the beam path during carbon and oxygen ion therapy.Approach.Phantoms of polyethylene, gelatin, or poly(methyl methacrylate) were irradiated with monoenergetic carbon and oxygen ion beams. Post-irradiation, 4D PET images were acquired and parent11C,10C and15O radionuclides contributions in each voxel were determined from the extracted time activity curves. Next, the experimental configurations were simulated in Geant4 Monte Carlo versions 10.0 to 11.1, with three different fragmentation models-binary ion cascade (BIC), quantum molecular dynamics (QMD) and the Liege intranuclear cascade (INCL++) - 30 model-version combinations. Total positron annihilation and parent isotope production yields predicted by each simulation were compared between simulations and experiments using normalised mean squared error and Pearson cross-correlation coefficient. Finally, we compared the depth of the maximum positron annihilation yield and the distal point at which the positron yield decreases to 50% of peak between each model and the experimental results.Main results.Performance varied considerably across versions and models, with no one version/model combination providing the best prediction of all positron-emitting fragments in all evaluated target materials and irradiation conditions. BIC in Geant4 10.2 provided the best overall agreement with experimental results in the largest number of test cases. QMD consistently provided the best estimates of both the depth of peak positron yield (10.4 and 10.6) and the distal 50%-of-peak point (10.2), while BIC also performed well and INCL generally performed the worst across most Geant4 versions.Significance.The best predictions of the spatial distribution of positron annihilations and positron-emitting fragment production along the beam path during carbon and oxygen ion therapy was obtained using Geant4 10.2.p03 with BIC or QMD. These version/model combinations are recommended for future heavy ion therapy research.


Subject(s)
Monte Carlo Method , Electrons/therapeutic use , Heavy Ion Radiotherapy/methods , Positron-Emission Tomography , Phantoms, Imaging
4.
J Chem Theory Comput ; 20(3): 1185-1192, 2024 Feb 13.
Article in English | MEDLINE | ID: mdl-38314701

ABSTRACT

Full configuration interaction (FCI) can provide an exact molecular ground-state energy within a given basis set and serve as a benchmark for approximate methods in quantum chemical calculations, including the emerging variational quantum eigensolver. However, its exponential computational and memory requirements easily exceed the capability of a single server and limit its applicability to large molecules. In this paper, we present a distributed FCI implementation employing a hybrid parallelization scheme with multithreading and multiprocessing to expand FCI's applicability. We optimize this scheme to minimize the bottlenecks arising from interprocess communications and interthread data management. Our implementation achieves higher scalability than the naive combination of prior works and successfully calculates the exact energy of C3H8/STO-3G with 1.31 trillion determinants, which is the largest FCI calculation to the best of our knowledge. Furthermore, we provide a comprehensive list of FCI results with 136 combinations of molecules and basis sets for future evaluation and development of approximate methods.

5.
Biomed Phys Eng Express ; 9(5)2023 08 29.
Article in English | MEDLINE | ID: mdl-37586333

ABSTRACT

Objective. A crosshair light sharing (CLS) PET detector as a TOF-DOI PET detector with high spatial resolution has been developed. To extend that work, a detector calibration method was developed to achieve both higher coincidence resolving time (CRT) and DOI resolution.Approach. The CLS PET detector uses a three-layer reflective material in a two-dimensional crystal array to form a loop structure within a pair of crystals, enabling a CRT of about 300 ps and acquisition of DOI from multi-pixel photon counter (MPPC) output ratios. The crystals were 1.45 × 1.45 × 15 mm3fast LGSO, and the crystal array was optically coupled to an MPPC array. It is important to reduce as many inter-crystal scattering (ICS) events as possible in advance for the accurate detector calibration. DOI information is also expected to improve the CRT because it can estimate the time delay due to the detection depth of crystals.Main results. Using crystal identification and light collection rate of the highest MPPC output reduces the number of ICS events, and CRT is improved by 26%. In addition, CRT is further improved by 13% with a linear correction of time delay as a function of energy. The DOI is ideally estimated from the output ratio of only the MPPC pairs optically coupled to the interacted crystals, which is highly accurate, but the error is large due to light leakage in actual use. The previous method, which also utilizes light leakage to calculate the output ratio, is less accurate, but the error can be reduced. Using the average of the two methods, it is possible to improve the DOI resolution by 12% while maintaining the smaller error.Significance. By applying the developed calibration method, the CLS PET detector achieves the CRT of 251 ps and the DOI resolution of 3.3 mm.


Subject(s)
Photons , Positron-Emission Tomography , Calibration , Positron-Emission Tomography/methods
6.
World J Surg Oncol ; 21(1): 44, 2023 Feb 13.
Article in English | MEDLINE | ID: mdl-36782222

ABSTRACT

BACKGROUND: Recently, there has been an increase in the number of reports of needle tract seeding (NTS) of tumor cells after a biopsy as one of the adverse events related to endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA). In most of the previously reported cases of NTS in pancreatic cancer, distal pancreatectomy was performed as the initial surgery, following which metachronous metastasis was discovered in the gastric wall, whose localization matched the puncture route of the EUS-FNA. We report a case of early metastasis from pancreatic cancer in the gastric wall, which was postulated to be caused by NTS. Our patient underwent a total pancreatectomy (TP), and the NTS was resected synchronously. CASE PRESENTATION: A 70-year-old woman with a diagnosis of pancreatic head-body-tail cancer presented to our department for surgery. Transgastric EUS-FNA and biopsy established the histological diagnosis in her case. We administered neoadjuvant chemotherapy (NAC) to the patient and performed a TP. Histopathological and immunohistochemical examination subsequently confirmed the diagnosis of pT3N1aM1 pancreatic adenocarcinoma and its gastric metastasis, which was caused by NTS. It is postulated that the tumor cells of NTS had progressed to develop the metastatic lesion in the gastric wall during the NAC period. This was also resected during the initial surgery. The patient developed an early postoperative recurrence in the peritoneum 8 months after the surgery. CONCLUSION: In pancreatic head cancer cases, the puncture route is often included in the resection area of radical surgery, and NTS is seldom considered as a potential clinical problem. However, NTS can progress rapidly and may be associated with early recurrence of malignancy. Therefore, when transgastrointestinal puncture is performed for the diagnosis of pancreatic cancer, the treatment strategy should be established considering the potential development of NTS.


Subject(s)
Adenocarcinoma , Pancreatic Neoplasms , Humans , Female , Aged , Pancreatic Neoplasms/pathology , Pancreatectomy/adverse effects , Adenocarcinoma/surgery , Endoscopic Ultrasound-Guided Fine Needle Aspiration/adverse effects , Neoplasm Seeding , Pancreatic Neoplasms
8.
Phys Med Biol ; 67(22)2022 11 16.
Article in English | MEDLINE | ID: mdl-36317319

ABSTRACT

Objective.For PET imaging systems, a smaller detector ring enables less intrinsic spatial resolution loss due to the photon non-collinearity effect as well as better balance between production cost and sensitivity, and a hemispherical detector arrangement is more appropriate for brain imaging than a conventional cylindrical arrangement. Therefore, we have developed a brain-dedicated PET system with a hemispherical detector arrangement, which has been commercialized in Japan under the product name of VRAINTM. In this study, we evaluated imaging performance of VRAIN.Approach.The VRAIN used 54 detectors to form the main hemispherical unit and an additional half-ring behind the neck. Each detector was composed of a 12 × 12 array of lutetium fine silicate crystals (4.1 × 4.1 × 10 mm3) and a 12 × 12 array of silicon photomultipliers (4 × 4 mm2active area) with the one-to-one coupling. We evaluated the physical performance of VRAIN according to the NEMA NU 2-2018 standards. Some measurements were modified so as to fit the hemispherical geometry. In addition, we performed18F-FDG imaging in a healthy volunteer.Main results.In the phantom study, the VRAIN showed high resolution for separating 2.2 mm rods, 229 ps TOF resolution and 19% scatter fraction. With the TOF gain for a 20 cm diameter object (an assumed head diameter), the peak noise-equivalent count rate was 144 kcps at 9.8 kBq ml-1and the sensitivity was 25 kcps MBq-1. Overall, the VRAIN provided excellent image quality in phantom and human studies. In the human FDG images, small brain nuclei and gray matter structures were clearly visualized with high contrast and low noise.Significance.We demonstrated the excellent imaging performance of VRAIN, which supported the advantages of the hemispherical detector arrangement.


Subject(s)
Fluorodeoxyglucose F18 , Positron-Emission Tomography , Humans , Positron-Emission Tomography/methods , Tomography, X-Ray Computed , Phantoms, Imaging , Brain/diagnostic imaging
9.
EJNMMI Phys ; 9(1): 69, 2022 Oct 08.
Article in English | MEDLINE | ID: mdl-36209191

ABSTRACT

BACKGROUND: To confirm the performance of the first hemispherical positron emission tomography (PET) for the brain (Vrain) that we developed to visualise the small nuclei in the deep brain area, we compared 18F-fluorodeoxyglucose (FDG) brain images with whole-body PET images. METHODS: Ten healthy male volunteers (aged 22-45 years) underwent a representative clinical whole-body PET, followed by Vrain each for 10 min. These two scans were initiated 30 min and 45 min after FDG injection (4.1 ± 0.5 MBq/kg), respectively. First, we visually identified the small nuclei and then compared their standardised uptake values (SUVs) with the participants' age. Next, the SUVs of each brain region, which were determined by applying a volume-of-interest template for anatomically normalised PET images, were compared between the brain images with the Vrain and those with the whole-body PET images. RESULTS: Small nuclei, such as the inferior colliculus, red nucleus, and substantia nigra, were more clearly visualised in Vrain than in whole-body PET. The anterior nucleus and dorsomedial nucleus in the thalamus and raphe nucleus in the brainstem were identified in Vrain but not in whole-body PET. The SUVs of the inferior colliculus and dentate gyrus in the cerebellum positively correlated with age (Spearman's correlation coefficient r = 0.811, p = 0.004; r = 0.738, p = 0.015, respectively). The SUVs of Vrain were slightly higher in the mesial temporal and medial parietal lobes than those in whole-body PET. CONCLUSIONS: This was the first time that the raphe nuclei, anterior nuclei, and dorsomedial nuclei were successfully visualised using the first hemispherical brain PET. TRIAL REGISTRATION  : Japan Registry of Clinical Trials, jRCTs032210086, Registered 13 May 2021, https://jrct.niph.go.jp/latest-detail/jRCTs032210086 .

10.
Org Lett ; 24(44): 8228-8232, 2022 11 11.
Article in English | MEDLINE | ID: mdl-36305771

ABSTRACT

A synthetic route to ecteinascidin 743 has been established via an intramolecular cascade Heck reaction to construct the diazabicyclo[3.3.1]nonane skeleton while controlling the two contiguous stereogenic centers. The strategically formed five-membered ring was oxidatively cleaved to generate a dialdehyde intermediate, from which the B ring of ecteinascidin 743 was constructed.


Subject(s)
Alkanes , Cyclization , Stereoisomerism , Trabectedin
11.
Vet Microbiol ; 273: 109523, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35961275

ABSTRACT

Methicillin-resistant Staphylococcus aureus (MRSA) is the leading cause of infection in hospitalized patients and can be prevalent in humans and various animal species. In European countries, MRSA isolates belonging to clonal complex 398 have been detected at high rates in pigs. However, the prevalence of MRSA in pigs and farm environments in Japan remains unclear. MRSA isolates were obtained from pigs in slaughterhouses, diseased pigs on farms, imported breeding pigs, and farm dust. We conducted whole-genome sequencing (WGS) and analyzed the molecular epidemiological relationship between these MRSA isolates using core genome multilocus sequence typing (cgMLST). The prevalence rates of MRSA among pigs in slaughterhouses, diseased pigs on farms, imported breeding pigs, and farm dust were 5.2 %, 3.4 %, 28.8 %, and 0.06 %, respectively. ST 398 isolates that classified as ST398/t034 were isolated from pigs from all sources. The results of cgMLST showed that ST398/t034 isolates originating from domestic pigs clustered into the same cluster as the isolates from imported breeding pigs. However, some clusters only included isolates of domestic pig origin. Most MRSA isolates in this study carried resistance genes for aminoglycosides, ß-lactams, macrolides, tetracyclines, and zinc. None of the MRSA isolates in this study harbored Panton-Valentine leukocidin toxin genes. Molecular epidemiological analysis suggested a relationship between isolates from slaughter pigs and imported breeding pigs and the presence of MRSA isolates of domestic origin. However, more data are needed for elucidation of the origin of these MRSA variants in the pig industry in Japan.


Subject(s)
Methicillin-Resistant Staphylococcus aureus , Staphylococcal Infections , Swine Diseases , Animals , Anti-Bacterial Agents/pharmacology , Dust , Humans , Japan/epidemiology , Microbial Sensitivity Tests/veterinary , Molecular Epidemiology , Multilocus Sequence Typing/veterinary , Staphylococcal Infections/epidemiology , Staphylococcal Infections/veterinary , Sus scrofa , Swine , Swine Diseases/epidemiology
12.
World J Gastroenterol ; 28(8): 868-877, 2022 Feb 28.
Article in English | MEDLINE | ID: mdl-35317096

ABSTRACT

BACKGROUND: During pancreaticoduodenectomy in patients with celiac axis (CA) stenosis due to compression by the median arcuate ligament (MAL), the MAL has to be divided to maintain hepatic blood flow in many cases. However, MAL division often fails, and success can only be determined intraoperatively. To overcome this problem, we performed endovascular CA stenting preoperatively, and thereafter safely performed pancreaticoduodenectomy. We present this case as a new preoperative treatment strategy that was successful. CASE SUMMARY: A 77-year-old man with a diagnosis of pancreatic head cancer presented to our department for surgery. Preoperative assessment revealed CA stenosis caused by MAL. We performed endovascular stenting in the CA preoperatively because we knew that going into the operation without a strategy could lead to ischemic complications. Double-antiplatelet therapy (DAPT) - which is needed when a stent is inserted - was then administered in parallel with neoadjuvant chemotherapy (NAC). This allowed us to administer DAPT for a sufficient period before the main pancreaticoduodenectomy procedure while obtaining therapeutic effects from NAC. Subtotal stomach-preserving pancreaticoduodenectomy was then performed. The operation did not require any unusual techniques and was performed safely. Postoperatively, the patient progressed well, without any ischemic complications. Histopathologically, curative resection was confirmed, and the patient had no recurrence or complications due to ischemia up to six months postoperatively. CONCLUSION: Preoperative endovascular stenting, with NAC and DAPT, is effective and safe prior to pancreaticoduodenectomy in potentially resectable pancreatic cancer.


Subject(s)
Arterial Occlusive Diseases , Pancreatic Neoplasms , Aged , Arterial Occlusive Diseases/etiology , Celiac Artery/diagnostic imaging , Celiac Artery/surgery , Constriction, Pathologic/etiology , Humans , Male , Pancreatic Neoplasms/complications , Pancreatic Neoplasms/surgery , Pancreaticoduodenectomy/adverse effects
13.
Surg Today ; 52(11): 1627-1633, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35338428

ABSTRACT

PURPOSE: Early management is crucial for acute intestinal blood flow disorders; however, no published study has identified criteria for the time limit for blood flow resumption. This study specifically examines the time factors for avoiding intestinal resection. METHODS: The subjects of this retrospective cohort study were 125 consecutive patients who underwent emergency surgery for a confirmed diagnosis of intestinal strangulation (n = 86), incarceration (n = 27), or volvulus (n = 12), between January 2015 and March 2021. Intestinal resection was performed when intestinal irreversible changes had occurred even after ischemia was relieved surgically. We analyzed the relationship between the time from computed tomography (CT) imaging to the start of surgery (C-S time) and intestinal resection using the Kaplan-Meier method and calculated the estimated intestinal rescue rate. Patient background factors affecting intestinal resection were also examined. RESULTS: The time limit for achieving 80% intestinal rescue rate was 200 min in C-S time, and when this exceeded 300 min, the intestinal rescue rate dropped to less than 50%. Multivariate analysis identified the APACHE II score as a significant influencing factor. CONCLUSION: A rapid transition from early diagnosis to early surgery is critical for patients with acute abdomen originating from intestinal blood flow disorders. The times from presentation at the hospital to surgery should be reduced further, especially for severe cases.


Subject(s)
Abdomen, Acute , Intestinal Obstruction , Intestinal Volvulus , Humans , Abdomen, Acute/etiology , Abdomen, Acute/surgery , Time Factors , Retrospective Studies , Intestinal Volvulus/diagnostic imaging , Intestinal Volvulus/surgery , Intestinal Volvulus/complications , Intestines/diagnostic imaging , Intestines/surgery , Intestinal Obstruction/diagnostic imaging , Intestinal Obstruction/etiology , Intestinal Obstruction/surgery
14.
Biomed Phys Eng Express ; 8(2)2022 02 28.
Article in English | MEDLINE | ID: mdl-35180713

ABSTRACT

Coincidence timing resolution (CTR) is an important parameter in clinical positron emission tomography (PET) scanners to increase the signal-to-noise ratio of PET images by using time-of-flight (TOF) information. Lutetium (Lu) based scintillators are often used for TOF-PET systems. However, the self-radiation of Lu-based scintillators may influence the image quality for ultra-low activity PET imaging. Recently, a gadolinium fine aluminum gallate (Ce:GFAG) scintillation crystal that features a fast decay time (∼55 ns) and no self-radiation was developed. The present study aimed at optimizing the GFAG crystal surface treatment to enhance both CTR and energy resolution (ER). The TOF-PET detector consisted of a GFAG crystal (3.0 × 3.0 × 20 mm3) and a SiPM with an effective area of 3.0 × 3.0 mm2. The timing and energy signals were extracted using a high-frequency SiPM readout circuit and then were digitized using a CAMAC DAQ system. The CTR and ER were evaluated with nine different crystal surface treatments such as partial saw-cut and chemical polishing and the 1-side saw-cut was the best choice among the treatments. The respective CTR and ER of 202 ± 2 ps and 9.5 ± 0.1% were obtained with the 1-side saw-cut; the other 5-side mechanically polished GFAG crystals had respective values which were 18 ps (9.0%) and 1.3% better than those of the all-side mechanically polished GFAG crystal. The chemically polished GFAG crystals also offered enhanced CTR and ER of about 17 ps (8.2%) and 2.1%, respectively, over the mechanically polished GFAG crystals.


Subject(s)
Photons , Positron-Emission Tomography , Aluminum , Lutetium , Positron-Emission Tomography/methods , Signal-To-Noise Ratio
15.
Front Plant Sci ; 13: 1024144, 2022.
Article in English | MEDLINE | ID: mdl-36743553

ABSTRACT

Rice is susceptible to abiotic stresses such as drought stress. To enhance drought resistance, elucidating the mechanisms by which rice plants adapt to intermittent drought stress that may occur in the field is an important requirement. Roots are directly exposed to changes in the soil water condition, and their responses to these environmental changes are driven by photosynthates. To visualize the distribution of photosynthates in the root system of rice plants under drought stress and recovery from drought stress, we combined X-ray computed tomography (CT) with open type positron emission tomography (OpenPET) and positron-emitting tracer imaging system (PETIS) with 11C tracer. The short half-life of 11C (20.39 min) allowed us to perform multiple experiments using the same plant, and thus photosynthate translocation was visualized as the same plant was subjected to drought stress and then re-irrigation for recovery. The results revealed that when soil is drier, 11C-photosynthates mainly translocated to the seminal roots, likely to promote elongation of the root with the aim of accessing water stored in the lower soil layers. The photosynthates translocation to seminal roots immediately stopped after rewatering then increased significantly in crown roots. We suggest that when rice plant experiencing drought is re-irrigated from the bottom of pot, the destination of 11C-photosynthates translocation immediately switches from seminal root to crown roots. We reveal that rice roots are responsive to changes in soil water conditions and that rice plants differentially adapts the dynamics of photosynthates translocation to crown roots and seminal roots depending on soil conditions.

16.
Vet Microbiol ; 263: 109266, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34739966

ABSTRACT

High pathogenic avian influenza viruses (HPAIVs) of the H5 subtype have spread in poultry and wild birds worldwide. Current studies have highlighted the association between the migration of wild birds and the spread of HPAIVs. However, virological studies examining responsible species of migratory birds to spread HPAIVs are limited. In Japan, the common teal (Anas crecca) arrives in great numbers for overwintering every autumn-spring season; therefore, we performed experimental infection using six H5 HPAIVs isolated in past outbreaks in Japan (A/chicken/Yamaguchi/7/2004 (H5N1), A/whooper swan/Akita/1/2008 (H5N1), A/mandarin duck/Miyazaki/22M-765/2011 (H5N1), A/duck/Chiba/26-372-48/2014 (H5N8), A/duck/Hyogo/1/2016 (H5N6) and A/mute swan/Shimane/3211A002/2017 (H5N6)) to evaluate the susceptibility of the species to HPAIV infection. The results illustrated that most birds in all experimental groups were infected by the strains, and they shed viruses for a prolonged period, in trachea than cloaca, without displaying distinctive clinical signs. In addition, comparative analysis using calculation value of total viral shedding during the experiment revealed that the birds shed viruses at above a certain level regardless of the differences of strains. These results suggested that the common teal could be a migratory bird species that disseminates viruses in the environment, thereby influencing HPAI outbreaks in wild birds in Japan.


Subject(s)
Disease Susceptibility , Ducks , Influenza A virus , Influenza in Birds , Animals , Disease Susceptibility/veterinary , Disease Susceptibility/virology , Ducks/virology , Influenza A virus/pathogenicity , Influenza A virus/physiology , Influenza in Birds/virology , Japan
17.
Phys Med Biol ; 66(22)2021 11 08.
Article in English | MEDLINE | ID: mdl-34644694

ABSTRACT

Objective.Time-of-flight (TOF) and depth-of-interaction (DOI) are well recognized as important information to improve PET image quality. Since such information types are not correlated, many TOF-DOI detectors have been developed but there are only a few reports of high-resolution detectors (e.g. 1.5 mm resolution) for brain PET systems. Based on the DOI detector, which enables single-ended readout by optically coupling a pair of crystals and having a loop structure, we have developed the crosshair light sharing (CLS) PET detector that optically couples the four-loop structure, consisting of quadrisected crystals comparable in size to a photo-sensor, to four photo-sensors in close proximity arranged in a windmill shape. Even as a high-resolution detector, the CLS PET detector could obtain both TOF and DOI information. The coincidence resolving time (CRT) of the CLS PET detector needs to be further improved, however, for application to the brain PET system. Recently, a fast LGSO crystal was developed which has advantages in detection efficiency and CRT compared to the GFAG crystal. In this work, we developed the CLS PET detector using the fast LGSO crystal for the TOF-DOI brain PET system.Approach.The crystals were each 1.45 × 1.45 × 15 mm3and all surfaces were chemically etched. The CLS PET detector consisted of a 14 × 14 crystal array optically coupled to an 8 × 8 MPPC array.Main results.The fast LGSO array provided 10.1% energy resolution at 511 keV, 4.7 mm DOI resolution at 662 keV, and 293 ps CRT with the energy window of 440-620 keV.Significance.The developed CLS PET detector has 290% higher coincidence sensitivity, 30% better energy resolution, and 32% better time resolution compared to our previous CLS PET detector.


Subject(s)
Brain , Positron-Emission Tomography , Brain/diagnostic imaging , Head , Humans , Positron-Emission Tomography/methods
18.
Nucl Med Commun ; 42(10): 1112-1121, 2021 Oct 01.
Article in English | MEDLINE | ID: mdl-34100794

ABSTRACT

BACKGROUND: In pancreatic cancer surgery, accurate identification and resection of intrapancreatic residual tumors are quite difficult. We have developed a novel open-typed PET system (called 'OpenPET'), which enables high-resolution PET-guided surgery in real time, and demonstrated that OpenPET-guided surgery with intraperitoneally administered 64Cu-labeled anti-epidermal growth factor receptor antibody cetuximab is useful to detect and resect primary pancreatic cancer. Here, we investigated applicability of OpenPET-guided surgery for unexpected residual intrapancreatic tumors and examined its survival benefit over conventional surgery. METHODS: A mouse model with large (>1 cm) resectable pancreatic cancer of xPA-1-DC cells expressing red fluorescent protein was used. OpenPET-guided surgery was conducted 24 h after intraperitoneal administration of 64Cu-labeled cetuximab (7.4 MBq/mouse). For comparison, similar surgical procedures were conducted, and conventional tumor resection was attempted using only the naked eye (control). Survival rate after OpenPET-guided surgery was compared to that after control operations. RESULTS: Intraoperative OpenPET guidance enabled detection and resection of small residual tumors. Ten residual tumor specimens (3-10 mm in diameter) were intraoperatively isolated with OpenPET guidance (n = 7 mice). All isolated specimens showed tumor RFP signals. No resection of tumor tissue was performed in control group because the tumor could not be clearly detected with the naked eye alone. Mice after OpenPET-guided surgery showed significantly longer survival rates than those in control group. CONCLUSIONS: OpenPET-guided surgery with 64Cu-labeled-cetuximab enabled intraoperative identification and resection of intrapancreatic small residual tumors. This technology could be useful to prevent tumor residuals during surgery and improve pancreatic cancer survival.


Subject(s)
Copper Radioisotopes
19.
Phys Med Biol ; 66(7)2021 03 29.
Article in English | MEDLINE | ID: mdl-33721860

ABSTRACT

Myocardial perfusion imaging (MPI) with PET plays a vital role in the management of coronary artery disease. High sensitivity systems can contribute to maximizing the potential value of PET MPI; therefore, we have proposed two novel detector arrangements, an elliptical geometry and a D-shape geometry, that are more sensitive and more compact than a conventional large-bore cylindrical geometry. Here we investigate two items: the benefits of the proposed geometries for cardiac imaging; and the effects of scatter components on cardiac PET image quality. Using the Geant4 toolkit, we modeled four time-of-flight (TOF) PET systems: an 80 cm diameter cylinder, a 40 cm diameter cylinder, a compact ellipse, and a compact D-shape. Spatial resolution and sensitivity were measured using point sources. Noise equivalent count rate and image quality were examined using an anthropomorphic digital chest phantom. The proposed geometries showed higher sensitivity and better count rate characteristics with a fewer number of detectors than the conventional large-bore cylindrical geometry. In addition, we found that the increased intensity of the scatter components was a big factor affecting the contrast in defect regions for such a compact geometry. It is important to address the issue of the increased intensity of the scatter components to develop a high-performance compact cardiac TOF PET system.


Subject(s)
Positron-Emission Tomography , Tomography, X-Ray Computed , Computer Simulation , Image Processing, Computer-Assisted/methods , Monte Carlo Method , Phantoms, Imaging , Positron-Emission Tomography/methods
20.
Phys Med Biol ; 66(6): 065013, 2021 03 08.
Article in English | MEDLINE | ID: mdl-33607635

ABSTRACT

The crosshair light-sharing (CLS) PET detector is our original depth-of-interaction (DOI) detector, which is based on a single-ended readout scheme with quadrisected crystals comparable in size to a photo-sensor. In this work, we developed 32 CLS PET detectors, each of which consisted of a multi-pixel photon counter (MPPC) array and gadolinium fine aluminum garnet (GFAG) crystals, and we developed a benchtop prototype of a small animal size PET. Each GFAG crystal was 1.45 × 1.45 × 15 mm3. The MPPC had a surface area of 3.0 × 3.0 mm2. The benchtop prototype had two detector rings of 16 detector blocks. The ring diameter and axial field-of-view were 14.2 cm and 4.9 cm, respectively. The data acquisition system used was the PETsys silicon photomultiplier readout system. The continuous DOI information was binned into three DOI layers by applying a look-up-table to a 2D position histogram. Also, energy and timing information was corrected using DOI information. After the calibration procedure, the energy resolution and the coincidence time resolution were 14.6% and 531 ps, respectively. Imaging test results of a small rod phantom obtained by an iterative reconstruction method showed clear separation of 1.6 mm rods with the help of DOI information.


Subject(s)
Phantoms, Imaging , Positron-Emission Tomography/methods , Tomography, X-Ray Computed/methods , Aluminum , Animals , Calibration , Equipment Design , Normal Distribution , Photons , Scintillation Counting , Software