Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Vasc Interv Radiol ; 32(2): 181-186, 2021 02.
Article in English | MEDLINE | ID: mdl-33288417

ABSTRACT

This report describes 7 cases in which multichannel balloon angioplasty was performed for severely calcified common femoral artery stenosis. After the successful passage of a guidewire through the stenosis, another guidewire with a tip load of 12g or 14 g was passed through a different channel inside the calcified plaques, followed by balloon angioplasty via each route. After the procedure, ankle brachial index improved from 0.49 ± 0.23 to 0.89 ± 0.05 on an average, and 6 of the 7 patients had patent arteries at a median follow-up period of 13 months. Multichannel balloon angioplasty offers the promise of being an effective endovascular intervention to expand calcified lesions.


Subject(s)
Angioplasty, Balloon , Femoral Artery , Peripheral Arterial Disease/therapy , Vascular Calcification/therapy , Aged , Aged, 80 and over , Angioplasty, Balloon/adverse effects , Ankle Brachial Index , Female , Femoral Artery/diagnostic imaging , Femoral Artery/physiopathology , Humans , Male , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Retrospective Studies , Severity of Illness Index , Time Factors , Treatment Outcome , Vascular Calcification/diagnostic imaging , Vascular Calcification/physiopathology , Vascular Patency
2.
Vasc Endovascular Surg ; 55(3): 277-281, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33034266

ABSTRACT

PURPOSE: In endovascular aneurysm repair, parallel stent graft deployment is sometimes utilized to preserve the distal branch perfusion. However, there will be some gutter space around 2 stent grafts, which may cause endoleak. The "eye of the tiger" technique was invented to minimize this leak when deploying a small side-branch stent graft in conjunction with a large aortic endograft. The purpose of this case report is to describe our modified technique for 2 small endografts deployed in double D-shape in order to prevent gutter leak, which we applied in endovascular treatment for a hypogastric artery aneurysm. CASE REPORT: A 79-year-old male patient presented with a right hypogastric artery aneurysm measuring 44 mm. The patient refused the open surgical repair option and hoped for an endovascular treatment. Therefore, endovascular treatment to exclude the hypogastric artery aneurysm as well as preserve the gluteal arteries was planned. An Internal Iliac Component (IIC)(W. L. Gore & Associates, Flagstaff, AZ, USA) was utilized for the proximal sealing and 2 Viabahn stent grafts (W. L. Gore & Associates) were deployed in the superior and inferior gluteal arteries for distal sealing. Then, 2 VBX stent grafts (W. L. Gore & Associates) were added in the IIC as bridging stents to connect the IIC and both Viabahn stent grafts. Next, over-dilatation of VBX stent grafts was performed alternately with an 8 mm balloon catheter and subsequent kissing balloon dilation with 5 mm balloon catheters, which allowed the VBX stents to be set in double D-shape. A follow-up CT scan performed 1 week after the procedure revealed no endoleak and a favorable shape to the VBX stent grafts. CONCLUSION: The modified method of dilating the VBX stent grafts allowed the double D-shape deployment, minimizing the risk of gutter leak and preserving distal branch perfusion.


Subject(s)
Aneurysm/surgery , Arteries/surgery , Blood Vessel Prosthesis Implantation , Buttocks/blood supply , Endovascular Procedures , Intermittent Claudication/prevention & control , Ischemia/prevention & control , Pelvis/blood supply , Aged , Aneurysm/diagnostic imaging , Aneurysm/physiopathology , Arteries/diagnostic imaging , Arteries/physiopathology , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Humans , Intermittent Claudication/etiology , Intermittent Claudication/physiopathology , Ischemia/etiology , Ischemia/physiopathology , Male , Regional Blood Flow , Stents , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...