1.
Polymers (Basel) ; 12(2)2020 Feb 05.
Article in English | MEDLINE | ID: mdl-32033360

ABSTRACT

Stretchable nano-fibers have attracted dramatic attention for the utility in wearable and flexible electronics. In the present case, Ag nanowires (AgNWs)-intertwined thermoplastic polyurethanes (TPU) unwoven nano-membrane is fabricated by an electrospinning method and dip coating technique. Then a strain sensor with a spring-like configuration is fabricated by a twisted method. The sensor exhibits superior electrical conductivity up to 3990 S cm-1 due to the high weight percentage of the Ag nanowires. Additionally, thanks to the free-standing spring-like configuration that consists of uniform neat loops, the strain sensor can detect a superior strain up to 900% at the point the sensor ruptures. On the other hand, the configuration can mostly protect the AgNWs from falling off. Furthermore, major human motion detection, like movement of a human forefinger, and minor human motion detection, such as a wrist pulse, show the possible application of the sensor in the field of flexible electronics.

2.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-702217

ABSTRACT

Objective To evaluate the noninferiority of domestic electomyographic (EMG) evoked potential instrument utility on avoiding iatrogenic injury of nerve roots compare to the imported ones,and understand the methods,accuracy and practicability of domestic machine on monitoring nerve root at the fracture fixation process.Methods Domestic of Neurocare-C machine and Nicolet Viking select8 concurrent monitoring 30 cases of bone fracture fixation,including 20 cases of spinal fixation and 10 cases of fractures fixation of limbs and pelvic.The trend of positive change,the rate and amplitude variation of electromyographic response between two instruments were compared.Results The nerve root function could be accurately judged by EMG monitoring during operation.Intraoperative EMG could be detected by both domestic and imported instruments occurred in 5 patients,3 cases were internal fixation of vertebral fracture,1 case was humeral fractures fixation,1 case was pelvic fracture.The rate of electromyographic response of both domestic and imported instruments were 16.67%.There was no significant difference in amplitude variation of electromyographic response of quadriceps femoris,biceps femoris,rectus femoris and tibialis anterior between two instruments (P > 0.05).Conclusion Both domestic and imported EMG evoked potentials can accurately and timely respond to nerve root function,avoid nerve root injury,and ensure the safety of fracture fixation surgery.

SELECTION OF CITATIONS
SEARCH DETAIL
...