1.
Medicine (Baltimore) ; 101(10): e29041, 2022 Mar 11.
Article in English | MEDLINE | ID: mdl-35451415

ABSTRACT

RATIONALE: Goiter, an abnormal enlargement of the thyroid gland, can induce airway distortion or tracheal compression. Airway management can be challenging for anesthesiologists, depending on the location and size of the mass as well as the patient's airway conditions, although it is reported that most cases can easily be managed by oral intubation. PATIENT CONCERNS: A 61-year-old female patient who had planned for a total thyroidectomy due to a huge goiter was intubated with nerve integrity monitoring (NIM) tubes, using video laryngoscopy (VL) and oral fiberoptic bronchoscopy (FOB) alone. The respective attempts initially failed. DIAGNOSIS: The patient's thyroid mass extended from the C3 cervical spine level to the T1 thoracic spine level with retropharyngeal involvement, causing an upper airway anatomical alteration that made intubation difficult. FOB manipulation was challenging due to the acute angulation of the laryngeal inlet and the tongue and the consequent interruption by the epiglottis. There was resistance to tube introduction, despite counterclockwise rotation of the NIM tube, due to acute angulation of the larynx and circumferential narrowing of the oropharyngeal and supraglottic space. INTERVENTIONS: In the first step of FOB-guided intubation, external laryngeal manipulation (ELM) was performed to improve the angle of the glottic opening and to elevate epiglottis tip. This allowed for FOB introduction into the trachea. VL was then performed transorally to elevate the tongue base and increase space, using the blade. ELM was applied simultaneously to move the glottis lower, thereby reducing the angle of the tube passage. OUTCOMES: The NIM tube was successfully introduced into the trachea with counterclockwise rotation in FOB-guided intubation. LESSONS: The combination of techniques using basic and popular devices and maneuvers, such as ELM and VL, may be useful for the successful management of difficult airways related to retropharyngeal goiter, without the need for surgical airway.


Subject(s)
Goiter , Laryngoscopes , Larynx , Female , Fiber Optic Technology , Goiter/complications , Goiter/surgery , Humans , Intubation, Intratracheal/methods , Laryngoscopy/methods , Middle Aged
2.
Medicine (Baltimore) ; 99(51): e23665, 2020 Dec 18.
Article in English | MEDLINE | ID: mdl-33371104

ABSTRACT

ABSTRACT: Caudal epidural injection (CEI) is effective for lumbar spinal pain. However, accidental intravascular injection reduces therapeutic efficacy of CEI and leads to fatal complications such as hematoma, and neurologic deficit. Whitacre needle has been reported to be effective for reducing intravascular injection during transforaminal epidural injection, compared with Quincke needle. The bevel of Chiba needle is shorter than that of Quincke needle. In this study we compared Whitacre needle and Chiba needle on incidence of intravascular injection during CEI.This was a single-blind, randomized clinical consort study. After institutional Review Board approval, a total of 164 patients underwent CEI were randomly allocated to one of 2 group (Whitacre needle or Chiba needle group). Intravascular injection was assessed with real-time fluoroscopy. In addition, total procedure time was measured. Data were compared between groups, and P < .05 was consideredstatistically significant.There were no differences between groups in terms of patient demographic and clinical characteristics. There was no significant difference on incidence of intravascular injection between Whitacre and Chiba needle group (11% vs 19.5%, P = .192). However, the procedure time is significantly longer in the Whitacre than Chiba needle group (172.8 ±â€Š53.8 sec vs 147.1 ±â€Š61.1 sec, P = .005).Based on current study, our results indicated that Whitacre needle was not effective to decrease the incidence of intravascular injection during CEI, compared to Chiba needle.


Subject(s)
Injections, Epidural/adverse effects , Injections, Epidural/instrumentation , Needles/adverse effects , Aged , Female , Fluoroscopy , Humans , Male , Middle Aged , Needles/statistics & numerical data
3.
J Dent Anesth Pain Med ; 18(2): 115-117, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29744387

ABSTRACT

Lingual nerve injury is a rare complication of general anesthesia. The causes of lingual nerve injury following general anesthesia are multifactorial; possible mechanisms may include difficult laryngoscopy, prolonged anterior mandibular displacement, improper placement of the oropharyngeal airway, macroglossia and tongue compression. In this report, we have described a case of bilateral lingual nerve injury that was associated with orotracheal intubation for open reduction and internal fixation of the left distal radius fracture in a 61-year-old woman. In this case, early treatment with dexamethasone effectively aided the recovery of the injured lingual nerve.