Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Oral Oncol ; 49(9): 956-963, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23623404

ABSTRACT

OBJECTIVES: Radiation induced cranial nerve palsy (RICNP) involving the lower cranial nerves (CNs) is a serious complication of head and neck radiotherapy (RT). Recommendations for delineating the lower CNs on RT planning studies do not exist. The aim of the current study is to develop a standardized methodology for contouring CNs IX-XII, which would help in establishing RT limiting doses for organs at risk (OAR). METHODS: Using anatomic texts, radiologic data, and guidance from experts in head and neck anatomy, we developed step-by-step instructions for delineating CNs IX-XII on computed tomography (CT) imaging. These structures were then contoured on five consecutive patients who underwent definitive RT for locally-advanced head and neck cancer (LAHNC). RT doses delivered to the lower CNs were calculated. RESULTS: We successfully developed a contouring atlas for CNs IX-XII. The median total dose to the planning target volume (PTV) was 70Gy (range: 66-70Gy). The median CN (IX-XI) and (XII) volumes were 10c.c (range: 8-12c.c) and 8c.c (range: 7-10c.c), respectively. The median V50, V60, V66, and V70 of the CN (IX-XI) and (XII) volumes were (85, 77, 71, 65) and (88, 80, 74, 64) respectively. The median maximal dose to the CN (IX-XI) and (XII) were 72Gy (range: 66-77) and 71Gy (range: 64-78), respectively. CONCLUSIONS: We have generated simple instructions for delineating the lower CNs on RT planning imaging. Further analyses to explore the relationship between lower CN dosing and the risk of RICNP are recommended in order to establish limiting doses for these OARs.


Subject(s)
Cranial Nerves/anatomy & histology , Head and Neck Neoplasms/radiotherapy , Tomography, X-Ray Computed/methods , Humans
2.
J Comput Assist Tomogr ; 32(1): 32-8, 2008.
Article in English | MEDLINE | ID: mdl-18303285

ABSTRACT

OBJECTIVE: To determine small bowel distention, scanning time, and side effects of commercially available oral contrast agents used in cross-sectional enterography. METHODS: Ten healthy volunteers ingested 2000 mL of water, methylcellulose, polyethylene glycol (PEG), or 1350 mL of low-concentration barium (LCB) followed by 500 mL water on different days. Magnetic resonance imaging occurred every 10 minutes from 30 to 90 minutes after ingestion. Small bowel distention was compared between time points and agents. Volunteers ranked side effects, drinking difficulty, and preference. RESULTS: By quantitative assessment, PEG and LCB distended small bowel loops better than water and methylcellulose (P < 0.0001). Time to optimal distention of the terminal ileum was from 51 to 72 minutes. Water and methylcellulose had the fewest side effects. Water was the most preferred contrast and PEG the least. CONCLUSIONS: Polyethylene glycol and LCB distend small bowel better than water and methylcellulose. Polyethylene glycol was the most difficult to drink and least preferred agent.


Subject(s)
Contrast Media/administration & dosage , Contrast Media/adverse effects , Intestine, Small/drug effects , Intestine, Small/diagnostic imaging , Magnetic Resonance Imaging/methods , Administration, Oral , Adult , Barium Sulfate/administration & dosage , Barium Sulfate/adverse effects , Drug Administration Schedule , Female , Humans , Image Enhancement/methods , Intestine, Small/anatomy & histology , Male , Methylcellulose/administration & dosage , Methylcellulose/adverse effects , Patient Satisfaction , Polyethylene Glycols/administration & dosage , Polyethylene Glycols/adverse effects , Prospective Studies , Reference Values , Severity of Illness Index , Time Factors , Tomography, X-Ray Computed/methods , Water/administration & dosage
3.
AJR Am J Roentgenol ; 188(1): 122-9, 2007 Jan.
Article in English | MEDLINE | ID: mdl-17179354

ABSTRACT

OBJECTIVE: The risk of invasive colorectal cancer in colorectal polyps correlates with lesion size. Our purpose was to define the most accurate methods for measuring polyp size at CT colonography (CTC) using three models of workstations and multiple observers. MATERIALS AND METHODS: Six reviewers measured 24 unique polyps of known size (5, 7, 10, and 12 mm), shape (sessile, flat, and pedunculated), and location (straight or curved bowel segment) using CTC data sets obtained at two doses (5 mAs and 65 mAs) and a previously described colonic phantom model. Reviewers measured the largest diameter of polyps on three proprietary workstations. Each polyp was measured with lung and soft-tissue windows on axial, 2D multiplanar reconstruction (MPR), and 3D images. RESULTS: There were significant differences among measurements obtained at various settings within each workstation (p < 0.0001). Measurements on 2D images were more accurate with lung window than with soft-tissue window settings (p < 0.0001). For the 65-mAs data set, the most accurate measurements were obtained in analysis of axial images with lung window, 2D MPR images with lung window, and 3D tissue cube images for Wizard, Advantage, and Vitrea workstations, respectively, without significant differences in accuracy among techniques (0.11 < p < 0.59). The mean absolute error values for these optimal settings were 0.48 mm, 0.61 mm, and 0.76 mm, respectively, for the three workstations. Within the ultralow-dose 5-mAs data set the best methods for Wizard, Advantage, and Vitrea were axial with lung window, 2D MPR with lung window, and 2D MPR with lung window, respectively. Use of nearly all measurement methods, except for the Vitrea 3D tissue cube and the Wizard 2D MPR with lung window, resulted in undermeasurement of the true size of the polyps. CONCLUSION: Use of CTC computer workstations facilitates accurate polyp measurement. For routine CTC examinations, polyps should be measured with lung window settings on 2D axial or MPR images (Wizard and Advantage) or 3D images (Vitrea). When these optimal methods are used, these three commercial workstations do not differ significantly in acquisition of accurate polyp measurements at routine dose settings.


Subject(s)
Colonic Polyps/diagnostic imaging , Colonography, Computed Tomographic/methods , Data Display , Imaging, Three-Dimensional/instrumentation , Radiographic Image Enhancement/instrumentation , Radiographic Image Interpretation, Computer-Assisted/instrumentation , Algorithms , Colonography, Computed Tomographic/instrumentation , Equipment Design , Equipment Failure Analysis , Female , Humans , Imaging, Three-Dimensional/methods , Male , Observer Variation , Phantoms, Imaging , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Reproducibility of Results , Sensitivity and Specificity , Signal Processing, Computer-Assisted
4.
Radiographics ; 26(3): 641-57; discussion 657-62, 2006.
Article in English | MEDLINE | ID: mdl-16702444

ABSTRACT

Computed tomographic (CT) enterography combines the improved spatial and temporal resolution of multi-detector row CT with large volumes of ingested neutral enteric contrast material to permit visualization of the small bowel wall and lumen. Adequate luminal distention can usually be achieved with oral hyperhydration, thereby obviating nasoenteric intubation and making CT enterography a useful, well-tolerated study for the evaluation of diseases affecting the mucosa and bowel wall. Unlike routine CT, which has been used to detect the extraenteric complications of Crohn disease such as fistula and abscess, CT enterography clearly depicts the small bowel inflammation associated with Crohn disease by displaying mural hyperenhancement, stratification, and thickening; engorged vasa recta; and perienteric inflammatory changes. As a result, CT enterography is becoming the first-line modality for the evaluation of suspected inflammatory bowel disease. CT enterography has also become an important alternative to traditional fluoroscopy in the assessment of other small bowel disorders such as celiac sprue and small bowel neoplasms.


Subject(s)
Contrast Media , Gastrointestinal Agents , Inflammatory Bowel Diseases/diagnostic imaging , Intestine, Small/diagnostic imaging , Radiographic Image Enhancement/methods , Tomography, X-Ray Computed/methods , Humans , Practice Guidelines as Topic , Practice Patterns, Physicians' , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...