Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Eur J Radiol ; 145: 110029, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34801874

ABSTRACT

PURPOSE: To assess the impact of adjunctive ultrasound guided diffuse optical tomography (US-guided DOT) on BI-RADS assessment in women undergoing US-guided breast biopsy. METHOD: This prospective study enrolled women referred for US-guided breast biopsy between 3/5/2019 and 3/19/2020. Participants underwent US-guided DOT immediately before biopsy. The US-guided DOT acquisition generated average maximum total hemoglobin (HbT) spatial maps and quantitative HbT values. Four radiologists blinded to histopathology assessed conventional imaging (CI) to assign a CI BI-RADS assessment and then integrated DOT information in assigning a CI&DOT BI-RADS assessment. HbT was compared between benign and malignant lesions using an ANOVA test and Tukey's test. Benign biopsies were tabulated, deeming BI-RADS ≥ 4A as positive. Reader agreement was assessed. RESULTS: Among 61 included women (mean age 48 years), biopsy demonstrated 15 (24.6%) malignant and 46 (75.4%) benign lesions. Mean HbT was 55.3 ± 22.6 µM in benign lesions versus 85.4 ± 15.6 µM in cancers (p < .001). HbT threshold of 78.5 µM achieved sensitivity 80% (12/15) and specificity 89% (41/46) for malignancy. Across readers and patients, 197 pairs of CI BI-RADS and CI&DOT BI-RADS assessments were assigned. Adjunctive US-guided DOT achieved a net decrease in 23.5% (31/132) of suspicious (CI BI-RADS ≥ 4A) assessments of benign lesions (34 correct downgrades and 3 incorrect upgrades). 38.3% (31/81) of 4A assessments were appropriately downgraded. No cancer was downgraded to a non-actionable assessment. Interreader agreement analysis demonstrated kappa = 0.48-0.53 for CI BI-RADS and kappa = 0.28-0.44 for CI&DOT BI-RADS. CONCLUSIONS: Integration of US-guided DOT information achieved a 23.5% reduction in suspicious BI-RADS assessments for benign lesions. Larger studies are warranted, with attention to improved reader agreement.


Subject(s)
Breast Neoplasms , Tomography, Optical , Biopsy , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Female , Humans , Middle Aged , Prospective Studies , Retrospective Studies , Ultrasonography, Interventional , Ultrasonography, Mammary
2.
AJR Am J Roentgenol ; 211(5): 1155-1170, 2018 11.
Article in English | MEDLINE | ID: mdl-30106610

ABSTRACT

OBJECTIVE: Optoacoustic ultrasound breast imaging is a fused anatomic and functional modality that shows morphologic features, as well as hemoglobin amount and relative oxygenation within and around breast masses. The purpose of this study is to investigate the positive predictive value (PPV) of optoacoustic ultrasound features in benign and malignant masses. SUBJECTS AND METHODS: In this study, 92 masses assessed as BI-RADS category 3, 4, or 5 in 94 subjects were imaged with optoacoustic ultrasound. Each mass was scored by seven blinded independent readers according to three internal features in the tumor interior and two external features in its boundary zone and periphery. Mean and median optoacoustic ultrasound scores were compared with histologic findings for biopsied masses and nonbiopsied BI-RADS category 3 masses, which were considered benign if they were stable at 12-month follow-up. Statistical significance was analyzed using a two-sided Wilcoxon rank sum test with a 0.05 significance level. RESULTS: Mean and median optoacoustic ultrasound scores for all individual internal and external features, as well as summed scores, were higher for malignant masses than for benign masses (p < 0.0001). High external scores, indicating increased hemoglobin and deoxygenation and abnormal vessel morphologic features in the tumor boundary zone and periphery, better distinguished benign from malignant masses than did high internal scores reflecting increased hemoglobin and deoxygenation within the tumor interior. CONCLUSION: High optoacoustic ultrasound scores, particularly those based on external features in the boundary zone and periphery of breast masses, have high PPVs for malignancy and, conversely, low optoacoustic ultrasound scores have low PPV for malignancy. The functional component of optoacoustic ultrasound may help to overcome some of the limitations of morphologic overlap in the distinction of benign and malignant masses.


Subject(s)
Breast Neoplasms/diagnostic imaging , Photoacoustic Techniques/methods , Ultrasonography, Mammary/methods , Adult , Breast Neoplasms/pathology , Female , Humans , Image Enhancement , Middle Aged
3.
AJR Am J Roentgenol ; 211(3): 689-700, 2018 09.
Article in English | MEDLINE | ID: mdl-29975115

ABSTRACT

OBJECTIVE: False-positive findings remain challenging in breast imaging. This study investigates the incremental value of optoacoustic imaging in improving BI-RADS categorization of breast masses at ultrasound. SUBJECTS AND METHODS: The study device is an optoacoustic breast imaging device with a handheld duplex laser and internal gray-scale ultrasound probe, fusing functional and morphologic information (optoacoustic ultrasound). In this prospective multisite study, breast masses assessed as BI-RADS category 3, 4A, 4B, 4C, or 5 by site radiologists underwent both gray-scale ultrasound and optoacoustic imaging with the study device. Independent reader radiologists assessed internal gray-scale ultrasound and optoacoustic ultrasound features for each mass and assigned a BI-RADS category. The percentage of mass reads for which optoacoustic ultrasound resulted in a downgrade or upgrade of BI-RADS category relative to internal gray-scale ultrasound was determined. RESULTS: Of 94 total masses, 39 were biopsy-proven malignant, 44 were biopsy-proven benign, and 11 BI-RADS category 3 masses were stable at 12-month follow-up. The sensitivity of both optoacoustic ultrasound and internal gray-scale ultrasound was 97.1%. The specificity was 44.3% for optoacoustic ultrasound and 36.4% for internal gray-scale ultrasound. Using optoacoustic ultrasound, 41.7% of benign masses or BI-RADS category 3 masses that were stable at 12-month follow-up were downgraded to BI-RADS category 2 by independent readers; 36.6% of masses assigned BI-RADS category 4A were downgraded to BI-RADS category 3 or 2, and 10.1% assigned BI-RADS category 4B were downgraded to BI-RADS category 3 or 2. Using optoacoustic ultrasound, independent readers upgraded 75.0% of the malignant masses classified as category 4A, 4B, 4C, or 5, and 49.4% of the malignant masses were classified as category 4B, 4C, or 5. CONCLUSION: Optoacoustic ultrasound resulted in BI-RADS category downgrading of benign masses and upgrading of malignant masses compared with gray-scale ultrasound.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Photoacoustic Techniques/methods , Ultrasonography, Mammary/methods , Adult , Aged , False Negative Reactions , False Positive Reactions , Female , Humans , Middle Aged , Neoplasm Grading , Pilot Projects , Prospective Studies , Sensitivity and Specificity
4.
Magn Reson Imaging Clin N Am ; 26(2): 303-314, 2018 May.
Article in English | MEDLINE | ID: mdl-29622136

ABSTRACT

Accreditation through the American College of Radiology (ACR) Breast Magnetic Resonance Imaging Accreditation Program is necessary to qualify for reimbursement from Medicare and many private insurers and provides facilities with peer review on image acquisition and clinical quality. Adherence to ACR quality control and technical practice parameter guidelines for breast MR imaging and performance of a medical outcomes audit program will maintain high-quality imaging and facilitate accreditation. Economic factors likely to influence the practice of breast MR imaging include cost-effectiveness, competition with lower-cost breast-imaging modalities, and price transparency, all of which may lower the cost of MR imaging and allow for greater utilization.


Subject(s)
Accreditation/methods , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/economics , Insurance, Health, Reimbursement/economics , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging/standards , Breast/diagnostic imaging , Female , Humans , Magnetic Resonance Imaging/economics , Quality Assurance, Health Care , Societies, Medical , United States
5.
Radiology ; 287(2): 398-412, 2018 05.
Article in English | MEDLINE | ID: mdl-29178816

ABSTRACT

Purpose To compare the diagnostic utility of an investigational optoacoustic imaging device that fuses laser optical imaging (OA) with grayscale ultrasonography (US) to grayscale US alone in differentiating benign and malignant breast masses. Materials and Methods This prospective, 16-site study of 2105 women (study period: 12/21/2012 to 9/9/2015) compared Breast Imaging Reporting and Data System (BI-RADS) categories assigned by seven blinded independent readers to benign and malignant breast masses using OA/US versus US alone. BI-RADS 3, 4, or 5 masses assessed at diagnostic US with biopsy-proven histologic findings and BI-RADS 3 masses stable at 12 months were eligible. Independent readers reviewed US images obtained with the OA/US device, assigned a probability of malignancy (POM) and BI-RADS category, and locked results. The same independent readers then reviewed OA/US images, scored OA features, and assigned OA/US POM and a BI-RADS category. Specificity and sensitivity were calculated for US and OA/US. Benign and malignant mass upgrade and downgrade rates, positive and negative predictive values, and positive and negative likelihood ratios were compared. Results Of 2105 consented subjects with 2191 masses, 100 subjects (103 masses) were analyzed separately as a training population and excluded. An additional 202 subjects (210 masses) were excluded due to technical failures or incomplete imaging, 72 subjects (78 masses) due to protocol deviations, and 41 subjects (43 masses) due to high-risk histologic results. Of 1690 subjects with 1757 masses (1079 [61.4%] benign and 678 [38.6%] malignant masses), OA/US downgraded 40.8% (3078/7535) of benign mass reads, with a specificity of 43.0% (3242/7538, 99% confidence interval [CI]: 40.4%, 45.7%) for OA/US versus 28.1% (2120/7543, 99% CI: 25.8%, 30.5%) for the internal US of the OA/US device. OA/US exceeded US in specificity by 14.9% (P < .0001; 99% CI: 12.9, 16.9%). Sensitivity for biopsied malignant masses was 96.0% (4553/4745, 99% CI: 94.5%, 97.0%) for OA/US and 98.6% (4680/4746, 99% CI: 97.8%, 99.1%) for US (P < .0001). The negative likelihood ratio of 0.094 for OA/US indicates a negative examination can reduce a maximum US-assigned pretest probability of 17.8% (low BI-RADS 4B) to a posttest probability of 2% (BI-RADS 3). Conclusion OA/US increases the specificity of breast mass assessment compared with the device internal grayscale US alone. Online supplemental material is available for this article. © RSNA, 2017.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast/diagnostic imaging , Photoacoustic Techniques , Radiology , Ultrasonography, Mammary , Adult , Aged , Aged, 80 and over , Breast/cytology , Breast/pathology , Breast Neoplasms/pathology , Female , Humans , Image Enhancement , Middle Aged , Observer Variation , Photoacoustic Techniques/trends , Prospective Studies , Radiologists , Radiology/instrumentation , Radiology/trends , Reproducibility of Results , United States , Young Adult
6.
Radiographics ; 28(6): 1541-53, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18936020

ABSTRACT

Esophageal emergencies-primarily, perforation and conditions with the potential to progress to perforation-result in significant morbidity and mortality if they are not recognized and treated promptly. The spectrum of esophageal emergencies includes esophagitis, foreign body impaction, and traumatic esophageal injury. Because there is considerable variability in the clinical manifestations of emergent esophageal conditions, computed tomography (CT) may play both primary and complementary roles in their diagnosis and evaluation. An awareness of the CT findings associated with the spectrum of acute esophageal disease facilitates the accurate and prompt diagnosis of esophageal emergencies and thereby contributes to a more successful outcome.


Subject(s)
Critical Care/methods , Emergency Medical Services/methods , Esophageal Diseases/diagnostic imaging , Esophageal Perforation/diagnostic imaging , Esophagus/diagnostic imaging , Esophagus/injuries , Tomography, X-Ray Computed/methods , Esophageal Diseases/therapy , Esophageal Perforation/therapy , Humans , Rupture, Spontaneous/diagnosis , Rupture, Spontaneous/therapy
7.
Dis Aquat Organ ; 63(2-3): 267-71, 2005 Feb 28.
Article in English | MEDLINE | ID: mdl-15819443

ABSTRACT

Atlantic salmon Salmo salar skeletal muscle was examined for Kudoa thyrsites by polymerase chain reaction (PCR) and positive fish were further examined by in situ hybridization (ISH) and immunohistochemistry (IHC). The infection was detected in 42% of salmon by PCR following a 60 d exposure to infective seawater at a temperature of 10 degrees C (= 600 degree-days, degreeD). The parasite was detected by ISH in skeletal and cardiac muscle but not in gill, kidney, spleen, liver, stomach, intestine, pyloric caeca and skin. None of 4 monoclonal antibodies (2F4, 4H2, 1H2, 3E8) raised against mature K. thyrsites spores reacted with the stages identified by ISH following a 600 degreeD exposure, but they did react with ISH-identified stages following a 1600 degreeD exposure. In contrast, a polyclonal antibody reacted with K. thyrsites stages in salmon with both 600 and 1600 degreeD exposures, suggesting that the parasite observed in 600 degreeD infections represents an antigenically distinct developmental stage of K. thyrsites.


Subject(s)
Eukaryota/genetics , Fish Diseases/diagnosis , Fish Diseases/parasitology , Protozoan Infections, Animal/diagnosis , Salmo salar , Spores, Protozoan/metabolism , Animals , Antibodies, Monoclonal/metabolism , British Columbia , DNA Probes , Immunohistochemistry/veterinary , In Situ Hybridization/veterinary , Muscle, Skeletal/parasitology , Polymerase Chain Reaction/veterinary , Seawater/parasitology , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...