Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Biomed Eng Online ; 18(1): 92, 2019 Sep 04.
Article in English | MEDLINE | ID: mdl-31484584

ABSTRACT

BACKGROUND: Sleep problem or disturbance often exists in pain or neurological/psychiatric diseases. However, sleep scoring is a time-consuming tedious labor. Very few studies discuss the 5-stage (wake/NREM1/NREM2/transition sleep/REM) automatic fine analysis of wake-sleep stages in rodent models. The present study aimed to develop and validate an automatic rule-based classification of 5-stage wake-sleep pattern in acid-induced widespread hyperalgesia model of the rat. RESULTS: The overall agreement between two experts' consensus and automatic scoring in the 5-stage and 3-stage analyses were 92.32% (κ = 0.88) and 94.97% (κ = 0.91), respectively. Standard deviation of the accuracy among all rats was only 2.93%. Both frontal-occipital EEG and parietal EEG data showed comparable accuracies. The results demonstrated the performance of the proposed method with high accuracy and reliability. Subtle changes exhibited in the 5-stage wake-sleep analysis but not in the 3-stage analysis during hyperalgesia development of the acid-induced pain model. Compared with existing methods, our method can automatically classify vigilance states into 5-stage or 3-stage wake-sleep pattern with a promising high agreement with sleep experts. CONCLUSIONS: In this study, we have performed and validated a reliable automated sleep scoring system in rats. The classification algorithm is less computation power, a high robustness, and consistency of results. The algorithm can be implanted into a versatile wireless portable monitoring system for real-time analysis in the future.


Subject(s)
Signal Processing, Computer-Assisted , Sleep Stages , Animals , Automation , Electroencephalography , Hyperalgesia/physiopathology , Polysomnography , Rats , Wakefulness
2.
Biomed Eng Online ; 16(1): 128, 2017 Nov 13.
Article in English | MEDLINE | ID: mdl-29132359

ABSTRACT

BACKGROUND: Effect of neurofeedback training (NFT) on enhancement of cognitive function or amelioration of clinical symptoms is inconclusive. The trainability of brain rhythm using a neurofeedback system is uncertainty because various experimental designs are used in previous studies. The current study aimed to develop a portable wireless NFT system for alpha rhythm and to validate effect of the NFT system on memory with a sham-controlled group. METHODS: The proposed system contained an EEG signal analysis device and a smartphone with wireless Bluetooth low-energy technology. Instantaneous 1-s EEG power and contiguous 5-min EEG power throughout the training were developed as feedback information. The training performance and its progression were kept to boost usability of our device. Participants were blinded and randomly assigned into either the control group receiving random 4-Hz power or Alpha group receiving 8-12-Hz power. Working memory and episodic memory were assessed by the backward digital span task and word-pair task, respectively. RESULTS: The portable neurofeedback system had advantages of a tiny size and long-term recording and demonstrated trainability of alpha rhythm in terms of significant increase of power and duration of 8-12 Hz. Moreover, accuracies of the backward digital span task and word-pair task showed significant enhancement in the Alpha group after training compared to the control group. CONCLUSIONS: Our tiny portable device demonstrated success trainability of alpha rhythm and enhanced two kinds of memories. The present study suggest that the portable neurofeedback system provides an alternative intervention for memory enhancement.


Subject(s)
Alpha Rhythm , Memory/physiology , Neurofeedback/instrumentation , Wireless Technology , Adult , Cognition/physiology , Female , Healthy Volunteers , Humans , Male , Signal Processing, Computer-Assisted
3.
IEEE Trans Biomed Eng ; 64(7): 1547-1557, 2017 07.
Article in English | MEDLINE | ID: mdl-28113301

ABSTRACT

OBJECTIVE: In this study, a wearable actigraphy recording device with low sampling rate (1 Hz) for power saving and data reduction and a high accuracy wake-sleep scoring method for the assessment of sleep were developed. METHODS: The developed actigraphy recorder was successfully applied to overnight recordings of 81 subjects with simultaneous polysomnography (PSG) measurements. The total length of recording reached 639.8 h. A wake-sleep scoring method based on the concept of movement density evaluation and adaptive windowing was proposed. Data from subjects with good (N = 43) and poor (N = 16) sleep efficiency (SE) in the range of 52.7-97.42% were used for testing. The Bland-Altman technique was used to evaluate the concordance of various sleep measurements between the manual PSG scoring and the proposed actigraphy method. RESULTS: For wake-sleep staging, the average accuracy, sensitivity, specificity, and kappa coefficient of the proposed system were 92.16%, 95.02%, 71.30%, and 0.64, respectively. For the assessment of SE, the accuracy of classifying the subject with good or poor SE reached 91.53%. The mean biases of SE, sleep onset time, wake after sleep onset, and total sleep time were -0.95%, 0.74 min, 2.84 min, and -4.3 min, respectively. CONCLUSION: These experimental results demonstrate the robustness and reliability of our method using limited activity information to estimate wake-sleep stages during overnight recordings. SIGNIFICANCE: The results suggest that the proposed wearable actigraphy system is practical for the in-home screening of objective sleep measurements and objective evaluation of sleep improvement after treatment.


Subject(s)
Accelerometry/instrumentation , Actigraphy/instrumentation , Micro-Electrical-Mechanical Systems/instrumentation , Monitoring, Ambulatory/instrumentation , Polysomnography/instrumentation , Sleep Stages/physiology , Adult , Algorithms , Equipment Design , Equipment Failure Analysis , Humans , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Systems Integration , Technology Assessment, Biomedical , Young Adult
4.
J Neural Eng ; 8(4): 045001, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21775786

ABSTRACT

In this paper numerous alternative treatments in addition to pharmacological therapy are proposed for their use in epileptic patients. Epileptic animal models can play a crucial role in the performance evaluation of new therapeutic techniques. The objective of this research is to first develop various epileptic rat models; second, develop a portable wireless closed-loop seizure controller including on-line seizure detection and real-time electrical stimulation for seizure elimination; and third, apply the developed seizure controller to the animal models to perform on-line seizure elimination. The closed-loop seizure controller was applied to three Long-Evans rats with spontaneous spike-wave discharges (non-convulsive) and three Long-Evans rats with epileptiform activities induced by pentylenetetrazol (PTZ) injection (convulsive) for evaluation. The seizure detection accuracy is greater than 92% (up to 99%), and averaged seizure detection latency is less than 0.6 s for both spontaneous non-convulsive and PTZ-induced convulsive seizures. The average false stimulation rate is 3.1%. Near 30% of PTZ-induced convulsive seizures need more than two times of 0.5 s electrical stimulation for suppression and 90% of the non-convulsive seizures can be suppressed by only one 0.5 s electrical stimulation.


Subject(s)
Epilepsy/therapy , Seizures/therapy , Animals , Artificial Intelligence , Brain/physiology , Convulsants , Disease Models, Animal , Electric Impedance , Electric Stimulation , Electroencephalography , Entropy , Epilepsy/chemically induced , Epilepsy/diagnosis , Models, Statistical , Pentylenetetrazole , ROC Curve , Rats , Rats, Long-Evans , Seizures/chemically induced , Seizures/diagnosis
5.
Article in English | MEDLINE | ID: mdl-21096670

ABSTRACT

The worldwide prevalence of epilepsy is approximately 1%, and 25% of epilepsy patients cannot be treated sufficiently by available therapies. Brain stimulation with closed-loop seizure control has recently been proposed as an innovative and effective alternative. In this paper, a portable closed-loop brain computer interface for seizure control was developed and shown with several aspects of advantages, including high seizure detection rate (92-99% during wake-sleep states), low false detection rate (1.2-2.5%), and small size. The seizure detection and electrical stimulation latency was not greater than 0.6 s after seizure onset. A wireless communication feature also provided flexibility for subjects freeing from the hassle of wires. Experimental data from freely moving rats supported the functional possibility of a real-time closed-loop seizure controller.


Subject(s)
Biofeedback, Psychology/instrumentation , Deep Brain Stimulation/instrumentation , Electroencephalography/instrumentation , Seizures/diagnosis , Seizures/prevention & control , Therapy, Computer-Assisted/methods , User-Computer Interface , Animals , Computer Systems , Equipment Design , Equipment Failure Analysis , Rats , Signal Processing, Computer-Assisted/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...