Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Database
Language
Publication year range
1.
J Fungi (Basel) ; 10(3)2024 Feb 28.
Article in English | MEDLINE | ID: mdl-38535193

ABSTRACT

Modern efforts to influence materials science with principles of biology have allowed fungal mycelial materials to take a foothold and develop novel solutions for the circular bioeconomy of tomorrow. However, recent studies have shown that the value of tomorrow's green materials is not determined simply by their environmental viability, but rather by their ability to make the polluting materials of today obsolete. With an inherently strong structure of chitin and ß-glucan, the ever-adaptable mycelia of fungi can compete at the highest levels with a litany of materials from leather to polyurethane foam to paper to wood. There are significant efforts to optimize pure mycelial materials (PMMs) through the entire process of species and strain selection, mycelial growth, and fabrication. Indeed, the promising investigations of novel species demonstrate how the diversity of fungi can be leveraged to create uniquely specialized materials. This review aims to highlight PMMs' current trajectory, evaluate the successes in technology, and explore how these new materials can help shape a better tomorrow.

2.
J Biomech Eng ; 146(3)2024 03 01.
Article in English | MEDLINE | ID: mdl-38217114

ABSTRACT

Head impacts in bicycle accidents are typically oblique to the impact surface and transmit both normal and tangential forces to the head, causing linear and rotational head kinematics, respectively. Traditional expanded polystyrene (EPS) foam bicycle helmets are effective at preventing many head injuries, especially skull fractures and severe traumatic brain injuries (TBIs) (primarily from normal contact forces). However, the incidence of concussion from collisions (primarily from rotational head motion) remains high, indicating need for enhanced protection. An elastomeric honeycomb helmet design is proposed herein as an alternative to EPS foam to improve TBI protection and be potentially reusable for multiple impacts, and tested using a twin-wire drop tower. Small-scale normal and oblique impact tests showed honeycomb had lower oblique strength than EPS foam, beneficial for diffuse TBI protection by permitting greater shear deformation and had the potential to be reusable. Honeycomb helmets were developed based on the geometry of an existing EPS foam helmet, prototypes were three-dimensional-printed with thermoplastic polyurethane and full-scale flat and oblique drop tests were performed. In flat impacts, honeycomb helmets resulted in a 34% higher peak linear acceleration and 7% lower head injury criteria (HIC15) than EPS foam helmets. In oblique tests, honeycomb helmets resulted in a 30% lower HIC15 and 40% lower peak rotational acceleration compared to EPS foam helmets. This new helmet design has the potential to reduce the risk of TBI in a bicycle accident, and as such, reduce its social and economic burden. Also, the honeycomb design showed potential to be effective for repetitive impact events without the need for replacement, offering benefits to consumers.


Subject(s)
Brain Concussion , Brain Injuries, Traumatic , Craniocerebral Trauma , Humans , Biomechanical Phenomena , Head Protective Devices , Bicycling/injuries , Craniocerebral Trauma/prevention & control , Brain Injuries, Traumatic/prevention & control , Acceleration
3.
J Mech Behav Biomed Mater ; 124: 104850, 2021 12.
Article in English | MEDLINE | ID: mdl-34607300

ABSTRACT

MOTIVE: External vibration excitation might be key to many novel non-surgical interventions for pathologies in the musculoskeletal system and in other parts of the human organism. Lack of understanding about vibration patterns, their controllability, and reproducibility are three limitations of ongoing research. This study establishes a bovine vibration model and animal model replacements for future research. METHODS: We used biological samples (n=5) and one polyurethane sample of the bovine femur. Mechanical resonance was measured experimentally and analysed numerically by finite element method. MAIN RESULTS: The experiments obtained 5 distinct mode shapes for the biological sample set, with standard deviation < 7.5%. Finite element analysis of the biological samples can replicate experimental mode shape deflection. The use of polyurethane changes resonance character but results are also good approximations of the biological samples. CONCLUSIONS: A model of the bovine femur with consistent resonance behaviour is presented with alternatives (polyurethane and finite element analysis) that can serve in reducing the number of necessary biological samples. Future work will be to adapt results to human anatomy. Of clinical interest will be to influence bone pathologies such as post-surgical non-union, or bone functionality as part of haematopoiesis and endocrine secretion.


Subject(s)
Femur , Vibration , Animals , Cattle , Finite Element Analysis , Humans , Models, Biological , Models, Theoretical , Reproducibility of Results
4.
Mater Sci Eng C Mater Biol Appl ; 125: 112070, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33965119

ABSTRACT

The development of treatment strategies for improving secondary stability at the bone-implant interface is a challenge. Porous implants are one solution for improving long-term implant stability, but the osteoconduction process of implants into the bone can be slow. Strain-driven osteogenesis from the mechanostat theory offers insight into pathways for post-operative treatment but mechanisms to deliver strain to the bone-implant interface need refinement. In this work, the use of therapeutic ultrasound is simulated to induce resonance into a porous implant structure. Local strains through the scaffold are measured by varying systemic variables such as damping ratio, applied vibrational force, primary bone-implant stability, and input frequency. At the natural frequency of the system with applied forces of 0.5 N and a damping ratio of 0.5%, roughly half of the nodes in the simulated environment exceed the microstrain threshold of 1000 µÎµ required for new bone formation. A high degree of sensitivity was noted upon changing input frequency, with minor sensitivities arising from damping ratio and applied vibrational force. These findings suggest that the application of therapeutic resonance to improve osseointegration of the bone-implant interface may be viable for applications including dental implants or segmental bone defects.


Subject(s)
Dental Implants , Osseointegration , Bone-Implant Interface , Osteogenesis , Porosity , Prostheses and Implants
5.
J Mech Behav Biomed Mater ; 116: 104361, 2021 04.
Article in English | MEDLINE | ID: mdl-33550142

ABSTRACT

The geometry of a metallic scaffold is important for the success of bone implants, where the introduction of porosity can reduce stress shielding effects and allow for bone tissue integration. In this work, porous scaffolds were designed to closely mimic the natural structure of trabecular bone using selective Voronoi tessellation with preferential seeding. A workflow to generate these structures is introduced, where voided regions of seeds in the starting volume create preferential texture during polyhedral expansion, resulting in modified strut orientation in the implant. Anisotropy was digitally characterized by mean-intercept length and star volume distribution measurements to determine similarity to trabecular orientation. This work demonstrates that selective Voronoi tessellation is an effective method to generate biomimetic porous scaffolds with increased anisotropy and tunable strut architecture in three dimensions as a suitable alternative to patient-derived bone geometries.


Subject(s)
Biomimetics , Titanium , Anisotropy , Humans , Porosity , Prostheses and Implants
6.
J Mech Behav Biomed Mater ; 106: 103726, 2020 06.
Article in English | MEDLINE | ID: mdl-32250943

ABSTRACT

Post-operative therapy for joint replacement is often performed to optimize bone volume and bone-implant contact. Methods, such as pulsed therapeutic ultrasound, have been shown to be a valuable addition to regular physiotherapy to increase bone regeneration. To evaluate the efficacy of kilohertz-frequency (kHz) resonant stimuli to additively manufactured implant analogues, Saos-2 cells were seeded onto porous stainless steel scaffolds and flat substrates. Resonant frequency modes were mapped in the low kHz range, and cells were subjected to daily stimulus for 10 min at a frequency of 1.278 kHz. kHz-frequency excitation was found to increase normalized alkaline phosphatase production by almost twofold on metallic substrates relative to non-vibrated control scaffolds, while peak velocity influenced alkaline phosphatase production on porous scaffolds but not flat substrates. Total cell proliferation was downregulated by excitation, and all excited samples displayed larger variability. This work indicates that vibration within the range of 0.16-0.48 mm/s may reduce cell proliferation, but favour osteogenic gene expression. This study highlights the potential of using kHz-resonance therapy to mitigate early-onset pore occlusion to achieve uniform osseointegration through porous metallic scaffolds.


Subject(s)
Osteoblasts , Tissue Scaffolds , Vibration , Cell Proliferation , Osteogenesis , Porosity
SELECTION OF CITATIONS
SEARCH DETAIL