Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
J Am Coll Radiol ; 19(11S): S488-S501, 2022 11.
Article in English | MEDLINE | ID: mdl-36436972

ABSTRACT

Pulmonary embolism (PE) remains a common and important clinical condition that cannot be accurately diagnosed on the basis of signs, symptoms, and history alone. The diagnosis of PE has been facilitated by technical advancements and multidetector CT pulmonary angiography, which is the major diagnostic modality currently used. Ventilation and perfusion scans remain largely accurate and useful in certain settings. MR angiography can be useful in some clinical scenarios and lower-extremity ultrasound can substitute by demonstrating deep vein thrombosis; however, if negative, further studies to exclude PE are indicated. In all cases, correlation with the clinical status, particularly with risk factors, improves not only the accuracy of diagnostic imaging but also overall utilization. Other diagnostic tests have limited roles. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer-reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances in which peer-reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Subject(s)
Pulmonary Embolism , Societies, Medical , Humans , Evidence-Based Medicine , Pulmonary Embolism/diagnostic imaging , Lower Extremity , Risk Factors
2.
Catheter Cardiovasc Interv ; 96(4): 871-877, 2020 10 01.
Article in English | MEDLINE | ID: mdl-32562439

ABSTRACT

The intraaortic balloon pump (IABP) provides counterpulsation by displacing a 40-50 cc blood volume during diastole augmenting diastolic pressure. The rapid deflation of the balloon timed to the initiation of systole reduces the afterload of ventricular ejection and thus peak systolic pressure. As a direct result, IABP increases mean arterial pressure (MAP) and peak diastolic pressure while reducing systolic pressure and myocardial work. IABP increases coronary flow velocity in non-obstructed vessels, but does not increase flow across a severe obstruction as shown by intracoronary Doppler flow studies (Kern et al., Circulation, 1993;87:500-511 and Kern et al., Circulation 1991;84:II-485). There are few studies using pressure sensor guidewires to confirm these responses. We present a case illustrating the translesional hemodynamics using an angioplasty sensor pressure wire across a severe stenosis and the unique influence of the IABP.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Stenosis/therapy , Fractional Flow Reserve, Myocardial , Heart Failure/therapy , Hemodynamics , Intra-Aortic Balloon Pumping , Cardiac Catheterization/instrumentation , Cardiac Catheters , Coronary Stenosis/diagnosis , Coronary Stenosis/physiopathology , Heart Failure/diagnosis , Heart Failure/physiopathology , Humans , Male , Middle Aged , Severity of Illness Index , Transducers, Pressure , Treatment Outcome
3.
Mol Genet Metab ; 130(4): 289-296, 2020 08.
Article in English | MEDLINE | ID: mdl-32466960

ABSTRACT

INTRODUCTION: Alkaptonuria (AKU) is a rare inherited disorder of tyrosine metabolism resulting in an accumulation of homogentisic acid oxidation products in the joints and cardiovascular system. Aortic distensibility may be a non-invasive indicator of cardiovascular complications. Descending thoracic aortic distensibility in alkaptonuria has not been studied. METHODS: Patients diagnosed with alkaptonuria underwent Magnetic Resonance Imaging (MRI) and gated non-contrast and contrast-enhanced cardiovascular computed tomography. Using MRI cine images, aortic distensibility of the descending thoracic aorta was determined. RESULTS: Seventy-six patients with alkaptonuria were imaged. When compared to literature normal values, aortic distensibility in AKU was impaired (5.2 vs 6.2 × 10-3, p < .001). Aortic distensibility was inversely related to age (r = -0.6, p = .0001). Hypertensive patients with alkaptonuria had impaired distensibility compared to normotensive patients with alkaptonuria (4.6 vs 5.6 × 10-3, p = .03), and hyperlipidemic patients with alkaptonuria had impaired distensibility compared to non-hyperlipidemic patients with alkaptonuria (4.1 vs 6.0 × 10-3, p = .001). Male hypertensive patients with alkaptonuria had greater distensibility than their female counterparts (5.3 vs 2.9 × 10-3, p = .02). Similarly, male hyperlipidemic patients with alkaptonuria had greater distensibility than their female counterparts (4.8 vs 2.5 × 10-3, p < .01). Of patients with alkaptonuria, those with a coronary artery calcium (CAC) score greater than 100 had more impaired distensibility than those with a CAC score less than 100 (3.5 vs 5.1 × 10-3, p = .01) and those with aortic calcium score greater than 100 had impaired distensibility compared to those with an aortic calcium score less than 100 (3.2 vs 4.9 × 10-3, p = .02). Univariate analysis revealed age, aortic calcification, and hyperlipidemia to be significant factors of distensibility, and multiple regression analysis showed age as the only significant risk factor of distensibility. CONCLUSIONS: Patients with alkaptonuria have impaired aortic distensibility, which is likely an early marker for reduced cardiovascular health. Variables such as age, hypertension, hyperlipidemia, and aortic and coronary calcification were associated with impaired distensibility.


Subject(s)
Alkaptonuria/complications , Aorta, Thoracic/pathology , Vascular Calcification/pathology , Adult , Aged , Aged, 80 and over , Case-Control Studies , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prognosis , Vascular Calcification/etiology , Young Adult
4.
J Cardiovasc Comput Tomogr ; 14(6): 478-482, 2020.
Article in English | MEDLINE | ID: mdl-32273241

ABSTRACT

BACKGROUND: Multiple appropriate use criteria (AUC) exist for the evaluation of coronary artery disease (CAD), but there is little data on the agreement between AUC from different professional medical societies. The aim of this study is to compare the appropriateness of coronary computed tomography angiography (CCTA) exams assessed using multimodality AUC from the American College of Cardiology Foundation (ACCF) versus the American College of Radiology (ACR). METHODS: In a single-center prospective cohort study from June 2014 to 2016, 1005 consecutive subjects referred for evaluation of known or suspected CAD received a contrast-enhanced CCTA. The primary outcome was the agreement of appropriateness ratings using ACCF and ACR guidelines, measured by the kappa statistic. A secondary outcome was the rate of obstructive CAD by appropriateness rating. RESULTS: Among 1005 subjects, the median (5-95th percentile) age was 59 (37-76) years with 59.0% male. The ACCF criteria classified 39.6% (n = 398) appropriate, 24.2% (n = 243) maybe appropriate, and 36.2% (n = 364) rarely appropriate. The ACR guidelines classified 72.3% (n = 727) appropriate, 2.6% (n = 26) maybe appropriate, and 25.1% (n = 252) rarely appropriate. ACCF and ACR appropriateness ratings were in agreement for 55.0% (n = 553). Overall, there was poor agreement (kappa 0.27 [95% confidence interval 0.23-0.31]). By both AUC methods, a low rate of obstructive CAD was observed in the rarely appropriate exams (ACCF 7.1% [n = 26 of 364] and ACR 13.5% [n = 34 of 252]). CONCLUSIONS: Compared to ACCF criteria, the ACR guidelines of appropriateness were broader and classified significantly more CCTA exams as appropriate. The poor agreement between appropriateness ratings from the ACCF and ACR AUC guidelines evokes implications for reimbursement and future test utilization.


Subject(s)
Computed Tomography Angiography/standards , Coronary Angiography/standards , Coronary Artery Disease/diagnostic imaging , Practice Guidelines as Topic/standards , Societies, Medical/standards , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies
5.
Catheter Cardiovasc Interv ; 96(1): 236-242, 2020 07.
Article in English | MEDLINE | ID: mdl-32141693

ABSTRACT

Compressive pericardial physiology (i.e., cardiac tamponade) reduces ventricular chamber volume/filling and cardiac output, which exacerbates coexisting hemodynamic derangements. In this hemodynamic rounds, we demonstrate the interaction of two hemodynamic conditions in one patient with acute pericardial tamponade in the setting of aortic stenosis (AS). Simultaneous pressures across the aortic valve before and after relief of cardiac tamponade demonstrate an acute and uncommon improvement in the hemodynamics of AS.


Subject(s)
Aortic Valve Stenosis/physiopathology , Aortic Valve/physiopathology , Cardiac Tamponade/physiopathology , Hemodynamics , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnostic imaging , Cardiac Tamponade/complications , Cardiac Tamponade/diagnostic imaging , Cardiac Tamponade/therapy , Humans , Kidney Failure, Chronic/complications , Kidney Failure, Chronic/physiopathology , Male , Middle Aged , Pericardiocentesis , Recovery of Function , Treatment Outcome , Ventricular Function, Left
7.
Catheter Cardiovasc Interv ; 94(2): 301-307, 2019 Aug 01.
Article in English | MEDLINE | ID: mdl-31250528

ABSTRACT

Dyspnea due to mitral stenosis (MS) and/or pulmonary hypertension (PHT) in patients who may have both conditions presents a challenging diagnostic dilemma. The hemodynamic response to exercise is probably the most helpful method to arrive at the correct diagnosis and treatment algorithm. In this hemodynamic rounds discussion, we evaluated a patient with MS and PHT prior to the decision for mitral valvuloplasty. KEY POINTS: Symptoms in patients with mitral stenosis and pulmonary hypertension cannot always be attributed to one pathology. Catheter-based hemodynamics are often needed to differentiate valve from lung disease. Exercise hemodynamics can clarify the predominant pathology in complex clinical scenarios.


Subject(s)
Cardiac Catheterization , Exercise Test , Hemodynamics , Hypertension, Pulmonary/diagnosis , Mitral Valve Stenosis/diagnosis , Mitral Valve/physiopathology , Aged , Female , Humans , Hypertension, Pulmonary/complications , Hypertension, Pulmonary/physiopathology , Mitral Valve/diagnostic imaging , Mitral Valve Stenosis/complications , Mitral Valve Stenosis/physiopathology , Predictive Value of Tests , Severity of Illness Index
8.
Eur J Radiol ; 111: 1-5, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30691659

ABSTRACT

Assessing coronary artery calcium (CAC) is a valuable tool for individualizing cardiac risk assessment. In CAC scanning, this technical report assesses the use of a true model-based iterative reconstruction algorithm using forward projected model-based iterative reconstruction ("FIRST") and assess whether FIRST allows for reduced radiation dose CAC scanning on 320-detector row computed tomography (320-CT). Here, 100 consecutive patients prospectively underwent reduced and standard dose scans. For the patients (59 ± 9 years, 61% male) stratified by Agatston categories 0, 1-10, 11-100, 101-400,> 400, agreement between reduced dose with FIRST versus standard dose with FBP was excellent at 81% (95% CI: 73-88%) with kappa 0.74 (95% CI: 0.64-0.85). Median radiation exposure was 75% lower for reduced (0.35 mSv) versus standard dose (1.37 mSv) scans. In conclusion, agreement was excellent for reduced dose with FIRST and standard dose with FBP in 320-detector row CT CAC imaging in well-established categories of cardiovascular risk. These methods make it possible to reduce radiation exposure by 75%.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Tomography, X-Ray Computed , Vascular Calcification/diagnostic imaging , Algorithms , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Radiation Dosage , Risk Assessment , Tomography, X-Ray Computed/methods
10.
Int J Cardiol ; 228: 180-183, 2017 Feb 01.
Article in English | MEDLINE | ID: mdl-27865183

ABSTRACT

BACKGROUND: The use of cardiac computed tomography (CT) in the evaluation of adult congenital heart disease patients is limited due to concerns of high radiation doses. The purpose of this study was to prospectively assess whether low radiation dose cardiac CT is feasible to evaluate ventricular systolic function in adults with congenital heart disease. METHODS: The study group included 30 consecutive patients with significant congenital heart disease who underwent a total of 35 ECG-gated cardiac CT scans utilizing a 320-detector row CT scanner. Each study included a non-contrast scan and subsequent contrast-enhanced retrospectively-gated acquisition. Effective radiation dose was estimated by multiplying the dose length product by a k-factor of 0.014mSv/mGycm. RESULTS: The mean age of the patients was 34.4±8.9years, 60% were men, and mean body mass index was 24.2±4.3kg/m2. A majority of patients (n=28, 93.3%) had contraindications to cardiac MRI. A tube potential of 80kV was used in 27 (77.1%) of the contrast-enhanced scans. The mean signal-to-noise and contrast-to-noise ratios were 11.5±3.9 and 10.3±3.7, respectively. The median radiation dose for non-contrast and contrast-enhanced images were 0.1mSv (0.07-0.2mSv) and 0.94mSv (0.5-2.1mSv), respectively. All 35 CT scans were successfully analyzed for ventricular systolic function. CONCLUSIONS: A low radiation contrast-enhanced, retrospectively-gated cardiac CT with a median radiation dose of less than 1mSv was successful in evaluating ventricular systolic function in 30 consecutive adult congenital heart disease patients who underwent a total of 35 scans.


Subject(s)
Cardiac-Gated Imaging Techniques , Heart Defects, Congenital/diagnostic imaging , Tomography, X-Ray Computed , Adult , Contrast Media , Feasibility Studies , Female , Humans , Male , Middle Aged , Prospective Studies , Radiation Dosage , Young Adult
11.
J Cardiovasc Comput Tomogr ; 10(5): 359-63, 2016.
Article in English | MEDLINE | ID: mdl-27591767

ABSTRACT

BACKGROUND: Coronary artery calcium (CAC) predicts coronary heart disease events and is important for individualized cardiac risk assessment. This report assesses the interscan variability of CT for coronary calcium quantification using image acquisition with standard and reduced radiation dose protocols and whether the use of reduced radiation dose acquisition with iterative reconstruction (IR; "reduced-dose/IR ") allows for similar image quality and reproducibility when compared to standard radiation dose acquisition with filtered back projection (FBP; "standard-dose/FBP") on 320-detector row computed tomography (320-CT). METHODS: 200 consecutive patients (60 ± 9 years, 59% male) prospectively underwent two standard- and two reduced-dose acquisitions (800 total scans, 1600 reconstructions) using 320 slice CT and 120 kV tube voltage. Automated tube current modulation was used and for reduced-dose scans, prescribed tube current was lowered by 70%. Image noise and Agatston scores were determined and compared. RESULTS: Regarding stratification by Agatston score categories (0, 1-10, 11-100, 101-400, >400), reduced-dose/IR versus standard-dose/FBP had excellent agreement at 89% (95% CI: 86-92%) with kappa 0.86 (95% CI: 0.81-0.90). Standard-dose/FBP rescan agreement was 93% (95% CI: 89-96%) with kappa = 0.91 (95% CI: 0.86-0.95) while reduced-dose/IR rescan agreement was similar at 91% (95% CI: 87-94%) with kappa 0.88 (95% CI: 0.83-0.93). Image noise was significantly higher but clinically acceptable for reduced-dose/IR (18 Hounsfield Unit [HU] mean) compared to standard-dose/FBP (16 HU; p < 0.0001). Median radiation exposure was 74% lower for reduced- (0.37 mSv) versus standard-dose (1.4 mSv) acquisitions. CONCLUSION: Rescan agreement was excellent for reduced-dose image acquisition with iterative reconstruction and standard-dose acquisition with filtered back projection for the quantification of coronary calcium by CT. These methods make it possible to reduce radiation exposure by 74%. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov/ct2/show/NCT01621594. UNIQUE IDENTIFIER: NCT01621594.


Subject(s)
Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Multidetector Computed Tomography/methods , Radiation Dosage , Radiation Exposure/prevention & control , Radiographic Image Interpretation, Computer-Assisted/methods , Vascular Calcification/diagnostic imaging , Aged , Algorithms , Female , Humans , Male , Maryland , Middle Aged , Predictive Value of Tests , Prospective Studies , Radiation Exposure/adverse effects , Reproducibility of Results , Severity of Illness Index
12.
Transplantation ; 78(11): 1576-81, 2004 Dec 15.
Article in English | MEDLINE | ID: mdl-15591944

ABSTRACT

BACKGROUND: Transplantation of allogeneic tissues is becoming a wider practice for the replacement of organ function lost to congenital or acquired pathologies. Chronic immunosuppression remains a necessity to prevent organ rejection, despite increased risks of infection, organ toxicity, and malignancies. Abnormalities of female gonadal function in patients of reproductive age are recognized, however, pathological alterations of the reproductive system in patients treated with new generation immunosuppressive drugs are still poorly documented. METHODS: We report herein our observations of abnormalities of the reproductive system in 13 female recipients of allogeneic islets for type 1 diabetes, under immunosuppression therapy based on daclizumab induction and tacrolimus/sirolimus maintenance. RESULTS: Menstrual cycle alterations and clinically significant ovarian cysts were frequently observed in our patients, some requiring medical or surgical intervention. All ovarian cysts appeared of benign nature. CONCLUSIONS: Our findings suggest that pre- and posttransplant evaluation of female patients should include menstrual history, baseline pelvic ultrasound, and hormonal levels to assess the presence and monitor the progression of such alterations.


Subject(s)
Islets of Langerhans Transplantation/adverse effects , Menstrual Cycle , Ovary/physiopathology , Adolescent , Adult , Child, Preschool , Estradiol/blood , Female , Follicle Stimulating Hormone/blood , Humans , Immunosuppressive Agents/adverse effects , Luteinizing Hormone/blood , Middle Aged , Ovarian Cysts/etiology , Pelvis/diagnostic imaging , Progesterone/blood , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...