Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
IEEE Trans Biomed Eng ; PP2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39012732

ABSTRACT

Magneto-acousto-electrical tomography (MAET) is a hybrid imaging method that combines the high spatial resolution of ultrasonography with the high contrast of electrical impedance tomography (EIT). While most previous studies on MAET have focused on two-dimensional imaging, our recent research proposed a novel three-dimensional (3D) MAET method using B-mode and translational scanning. This method has been the first to reconstruct a 3D volume image of conductivity interfaces. However, this method has its limitations in mapping irregular shapes of conductivity. To address this challenge, we propose a 3D magneto-acousto-electrical computed tomography (3D MAE-CT) method utilizing an ultrasound linear array transducer in this work. Both phantom and in vitro experiments were conducted to validate our proposed method. The results from the phantom experiments demonstrate that our method can map the 3D volume conductivity with high spatial resolution. The oblique angles extracted from the 3D image closely match practical value, with the relative error ranging between -2.80% and 4.07%. Furthermore, the in vitro experiment successfully obtained a 3D image of a chicken heart, marking the first MAET 3D conductivity image of a tissue sample to date.

2.
IEEE Trans Biomed Eng ; 71(2): 669-678, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37698962

ABSTRACT

Magneto-acousto-electrical computed tomography (MAE-CT) is a recently developed rotational magneto-acousto-electrical tomography (MAET) method, which can map the conductivity parameter of tissues with high spatial resolution. Since the imaging mode of MAE-CT is similar to that of CT, the reconstruction algorithms for CT are possible to be adopted for MAE-CT. Previous studies have demonstrated that the filtered back-projection (FBP) algorithm, which is one of the most common CT reconstruction algorithms, can be used for MAE-CT reconstruction. However, FBP has some inherent shortcomings of being sensitive to noise and non-uniform distribution of views. In this study, we introduced iterative reconstruction (IR) method in MAE-CT reconstruction and compared its performance with that of the FBP. The numerical simulation, the phantom, and in vitro experiments were performed, and several IR algorithms (ART, SART, SIRT) were used for reconstruction. The results show that the images reconstructed by the FBP and IR are similar when the data is noise-free in the simulation. As the noise level increases, the images reconstructed by SART and SIRT are more robust to the noise than FBP. In the phantom experiment, noise and some stripe artifacts caused by the FBP are removed by SART and SIRT algorithms. In conclusion, the IR method used in CT is applicable in MAE-CT, and it performs better than FBP, which indicates that the state-of-the-art achievements in the CT algorithm can also be adopted for the MAE-CT reconstruction in the future.


Subject(s)
Quality Improvement , Radiographic Image Interpretation, Computer-Assisted , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Algorithms , Phantoms, Imaging
3.
IEEE Trans Biomed Eng ; 70(5): 1493-1503, 2023 05.
Article in English | MEDLINE | ID: mdl-36346865

ABSTRACT

As a tissue conductivity imaging method, magneto-acousto-electric tomography (MAET) has the advantage of high axial spatial resolution compared with traditional electrical impedance imaging methods. However, it has the problems of difficulty in imaging targets with irregular conductivity distribution and poor lateral spatial resolution. Although the rotation-based MAET method can partly solve the irregular target problem, there is still a poor imaging signal-to-noise ratio (SNR) problem. Our previous study established a framework of an innovative MAET method, which has a very similar imaging theory and reconstruction algorithm to those of computed tomography (CT). Therefore, we name the method magneto-acoustic-electric computed tomography (MAE-CT). This paper proposes an improved implementation of MAE-CT based on multi-angle plane wave excitation. This method combines the electronic steering of the linear array transducer with the mechanical rotation to increase the number of projection angles while keeping the imaging complexity. In this study, we first established a finite element simulation model to verify the method's feasibility. Then phantom experiments were conducted to systematically investigate the performance of the proposed method. Finally, in vitro liver tissue experiment was conducted to further explore the feasibility of the method. The experimental results show that our method improves both the SNR and spatial resolution of the reconstructed image. For the phantom results, this method can detect conductivity of 0.67 S/m in an area with a size of 2 mm. To the best of our knowledge, this is the best result of spatial resolution available for MAET.


Subject(s)
Tomography, X-Ray Computed , Tomography , Tomography, X-Ray Computed/methods , Tomography/methods , Electricity , Electric Conductivity , Acoustics , Phantoms, Imaging , Algorithms , Image Processing, Computer-Assisted/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...