Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Lett ; 35(9): 1404-6, 2010 May 01.
Article in English | MEDLINE | ID: mdl-20436584

ABSTRACT

We discuss the aberration-induced intensity imbalance of alternating phase-shifting mask (Alt-PSM) in lithographic imaging, in contrast to numerous studies on mask-induced intensity imbalance. Based on the Hopkins theory of partial coherent imaging, a linear relationship between the intensity difference of adjacent peaks in an Alt-PSM image and even aberration is established by formulations and verified by numerical results. The application of the linear relationship is briefly discussed.

2.
Appl Opt ; 48(19): 3654-63, 2009 Jul 01.
Article in English | MEDLINE | ID: mdl-19571920

ABSTRACT

A linear measurement model of lithographic projection lens aberrations is studied numerically based on the Hopkins theory of partially-coherent imaging and positive resist optical lithography (PROLITH) simulation. In this linearity model, the correlation between the mark's structure and its sensitivities to aberrations is analyzed. A method to design a mark with high sensitivity is proved and declared. By use of this method, a translational-symmetry alternating phase shifting mask (Alt-PSM) grating mark is redesigned with all of the even orders, +/-3rd and +/-5th order diffraction light missing. In the evaluation simulation, the measurement accuracies of aberrations prove to be enhanced apparently by use of the redesigned mark instead of the old ones.

3.
Appl Opt ; 48(2): 261-9, 2009 Jan 10.
Article in English | MEDLINE | ID: mdl-19137036

ABSTRACT

The correlation between the coma sensitivity of the alternating phase-shifting mask (Alt-PSM) mark and the mark's structure is studied based on the Hopkins theory of partially coherent imaging and positive resist optical lithography (PROLITH) simulation. It is found that an optimized Alt-PSM mark with its phase width being two-thirds its pitch has a higher sensitivity to coma than Alt-PSM marks with the same pitch and the different phase widths. The pitch of the Alt-PSM mark is also optimized by PROLITH simulation, and the structure of p=1.92lambda/NA and pw=2p/3 proves to be with the highest sensitivity. The optimized Alt-PSM mark is used as a measurement mark to retrieve coma aberration from the projection optics in lithographic tools. In comparison with an ordinary Alt-PSM mark with its phase width being a half its pitch, the measurement accuracies of Z(7) and Z(14) apparently increase.

4.
Opt Express ; 15(24): 15878-85, 2007 Nov 26.
Article in English | MEDLINE | ID: mdl-19550874

ABSTRACT

In this paper, we propose a novel method for measuring the coma aberrations of lithographic projection optics based on relative image displacements at multiple illumination settings. The measurement accuracy of coma can be improved because the phase-shifting gratings are more sensitive to the aberrations than the binary gratings used in the TAMIS technique, and the impact of distortion on displacements of aerial image can be eliminated when the relative image displacements are measured. The PROLITH simulation results show that, the measurement accuracy of coma increases by more than 25% under conventional illumination, and the measurement accuracy of primary coma increases by more than 20% under annular illumination, compared with the TAMIS technique.

SELECTION OF CITATIONS
SEARCH DETAIL
...