1.
Rinsho Byori ; 64(2): 152-6, 2016 Feb.
Article in Japanese | MEDLINE | ID: mdl-27311278

ABSTRACT

Microsemi LC-767CRP (LC-767, Horiba, Ltd.) is capable of simultaneous measuring of complete blood count (CBC) including 3-part differentials (3-part Diff.) of white blood cells (WBC) and C-reactive protein (CRP) in 4 minutes. Data obtained using LC-767 were intra-assay-reproducible (n = 10, CV = 0.6-4.0% for CBC, 0.6-2.5% for 3-part Diff. and 2.8-7.7% for CRP). They also showed the good linearity, no definite carry-over and the excellent correlations with routine instruments in our institution. Concerning CRP, the minimal detectable concentration revealed < 0.1 mg/dL, and prozone was observed in the sample containing > 30 mg/dL of CRP. LC-767 showed better correlation with a routine instrument in monocyte percentage than LC-667, probably due to modification of the hemolysis solution ratio and diluent temperature. In conclusion, LC-767 provided accurate CBC and CRP results, and showed improvement in CRP linearity and monocyte percentage compared with LC-667. LC-767, which is equipped with a bar-code reader with easy accessibility to electronic medical record, is suitable as the next-generation point of care testing model in the era of information and network-oriented medicine.


Subject(s)
C-Reactive Protein/analysis , Leukocyte Count/instrumentation , Adult , Aged , Aged, 80 and over , Biomarkers/blood , Female , Hemolysis , Humans , Leukocyte Count/methods , Leukocytes/classification , Male , Middle Aged , Reproducibility of Results , Solutions , Temperature , Young Adult
3.
Rinsho Byori ; 61(6): 482-7, 2013 Jun.
Article in Japanese | MEDLINE | ID: mdl-23947185

ABSTRACT

We collected the different volumes of venous blood(60 microL, 125 microL, 250 microL and 500 microL) into micro sample cups from respective volunteer to compare complete blood count (CBC) among 4 sample volumes, and found that 60 microL of sample volume seemed enough for CBC measurement using Microsemi LC-667 CRP (Horiba Co.). Subsequently, we measured CBC using 60 microL of peripheral blood after combining one of the 3 capillary tubes (heparin coated, EDTA coated and plain) with either EDTA coated or plain micro sample cups to examine the effect of anticoagulants contained into these commercially available maneuvers for capillary blood sampling. When we used the plain micro sample cup, platelet aggregation and false increase of white blood cell(WBC) count were observed irrespective to the combination of capillary tubes. We also tried whether commercially recommended volume (250 microL) of sample could be obtained by either fingertip or earlobe puncture from volunteers, and found that 7 of 16 fingertip and only 1 earlobe punctures could achieve sufficient volume. Whereas, at least 60 microL of sample were available more than 80% of volunteers by both methods, and CBC data obtained from these lesser samples obtained by fingertip puncture showed no statistically significant differences when compared with those of conventional venous samples (2 mL). From these findings, we concluded that at least 60 microL of capillary blood obtained from fingertip then collected into EDTA coated micro sample cup was enough to measure CBC using Microsemi LC-667 CRP.


Subject(s)
Anticoagulants/pharmacology , Blood Cell Count/methods , Blood Cells/pathology , Capillaries , Adult , Blood Specimen Collection/instrumentation , Blood Specimen Collection/methods , Female , Humans , Male , Middle Aged , Reproducibility of Results , Young Adult
4.
Int J Hematol ; 94(2): 169-177, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21732036

ABSTRACT

We evaluated the diagnostic utility of peripheral blood neutrophil distribution patterns obtained using the CELL-DYN SAPPHIRE hematology analyzer in patients with myelodysplastic syndrome (MDS). Peripheral blood was obtained from 467 individuals including 32 patients with MDS, and the respective neutrophil distribution patterns were observed using two light scatters [7-degree complexity (7D) and 90-degree lobularity (90D)]. These scattering intensities are shown as median (median neutrophil distribution: MND) and coefficient of variation (neutrophil distribution width: NDW). Generally, MDS patients showed lower 7D MND, higher 7D NDW, lower 90D MND and higher 90D NDW than other comparable groups. Whereas 90D parameters were more diagnostically efficient than 7D ones in patients with MDS. The sensitivity and specificity of 90D MND for MDS patients became 78.1 and 78.9%, respectively (cut-off value = 14,514). 90D NDW was most diagnostically effective with 87.5% sensitivity and 91.0% specificity (cut-off value = 21.2%). Both 90D parameters showed no evident correlation with the degree of either leukocytopenia or peripheral blood dysgranulopoiesis. In conclusion, neutrophil distribution parameters, especially 90D NDW, appear to provide convenient and objective markers for the screening of patients with MDS in routine laboratory hematology.


Subject(s)
Hematologic Tests/instrumentation , Myelodysplastic Syndromes/diagnosis , Neutrophils/pathology , Adult , Aged , Aged, 80 and over , Biomarkers/blood , Female , Humans , Light , Male , Middle Aged , Scattering, Radiation , Sensitivity and Specificity , Statistical Distributions
5.
Lab Hematol ; 14(2): 12-4, 2008.
Article in English | MEDLINE | ID: mdl-18599430

ABSTRACT

CD45, also referred to as the leukocyte common antigen (LCA), is selectively expressed on nucleated hematopoietic cells in healthy individuals. It is also widely expressed in various types of hematologic malignancies--although 10% of acute lymphoblastic leukemia and more than 50% of multiple myeloma have been reported to lack its expression. In this paper, we report a rare case of CD45-negative non-Hodgkin's lymphoma (NHL) that affected the thyroid gland.


Subject(s)
Leukocyte Common Antigens/analysis , Lymphoma, Large B-Cell, Diffuse/pathology , Thyroid Neoplasms/pathology , Aged , Flow Cytometry/methods , Humans , Immunophenotyping , Male