Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Magn Reson Imaging ; 44: 125-130, 2017 12.
Article in English | MEDLINE | ID: mdl-28888769

ABSTRACT

This prospective multi-center study aimed to evaluate the inter-vendor and test-retest reliabilities of resting-state functional magnetic resonance imaging (RS-fMRI) by assessing the temporal signal-to-noise ratio (tSNR) and functional connectivity. Study included 10 healthy subjects and each subject was scanned using three 3T MR scanners (GE Signa HDxt, Siemens Skyra, and Philips Achieva) in two sessions. The tSNR was calculated from the time course data. Inter-vendor and test-retest reliabilities were assessed with intra-class correlation coefficients (ICCs) derived from variant component analysis. Independent component analysis was performed to identify the connectivity of the default-mode network (DMN). In result, the tSNR for the DMN was not significantly different among the GE, Philips, and Siemens scanners (P=0.638). In terms of vendor differences, the inter-vendor reliability was good (ICC=0.774). Regarding the test-retest reliability, the GE scanner showed excellent correlation (ICC=0.961), while the Philips (ICC=0.671) and Siemens (ICC=0.726) scanners showed relatively good correlation. The DMN pattern of the subjects between the two sessions for each scanner and between three scanners showed the identical patterns of functional connectivity. The inter-vendor and test-retest reliabilities of RS-fMRI using different 3T MR scanners are good. Thus, we suggest that RS-fMRI could be used in multicenter imaging studies as a reliable imaging marker.


Subject(s)
Brain/anatomy & histology , Magnetic Resonance Imaging/methods , Adult , Brain Mapping/methods , Female , Humans , Male , Prospective Studies , Reference Values , Reproducibility of Results , Rest , Signal-To-Noise Ratio
2.
Korean J Radiol ; 17(5): 633-40, 2016.
Article in English | MEDLINE | ID: mdl-27587951

ABSTRACT

OBJECTIVE: Neuromelanin loss of substantia nigra (SN) can be visualized as a T1 signal reduction on T1-weighted high-resolution imaging. We investigated whether volumetric analysis of T1 hyperintensity for SN could be used to differentiate between Parkinson's disease dementia (PDD), Alzheimer's disease (AD) and age-matched controls. MATERIALS AND METHODS: This retrospective study enrolled 10 patients with PDD, 18 patients with AD, and 13 age-matched healthy elderly controls. MR imaging was performed at 3 tesla. To measure the T1 hyperintense area of SN, we obtained an axial thin section high-resolution T1-weighted fast spin echo sequence. The volumes of interest for the T1 hyperintense SN were drawn onto heavily T1-weighted FSE sequences through midbrain level, using the MIPAV software. The measurement differences were tested using the Kruskal-Wallis test followed by a post hoc comparison. RESULTS: A comparison of the three groups showed significant differences in terms of volume of T1 hyperintensity (p < 0.001, Bonferroni corrected). The volume of T1 hyperintensity was significantly lower in PDD than in AD and normal controls (p < 0.005, Bonferroni corrected). However, the volume of T1 hyperintensity was not different between AD and normal controls (p = 0.136, Bonferroni corrected). CONCLUSION: The volumetric measurement of the T1 hyperintensity of SN can be an imaging marker for evaluating neuromelanin loss in neurodegenerative diseases and a differential in PDD and AD cases.


Subject(s)
Dementia/diagnostic imaging , Melanins/metabolism , Parkinson Disease/diagnostic imaging , Substantia Nigra/diagnostic imaging , Aged , Aged, 80 and over , Alzheimer Disease/diagnostic imaging , Biomarkers/metabolism , Dementia/etiology , Diagnosis, Differential , Female , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , Observer Variation , Parkinson Disease/psychology , Retrospective Studies , Software , Substantia Nigra/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...