Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters











Language
Publication year range
1.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1025403

ABSTRACT

Objective:To identifying risk factors of postoperative pulmonary infection(POI)in gastric cancer(GC)patients as well as generating an effective nomogram for the POI.Methods:Pa-tients with gastric cancer after surgery from 1st January 2010 to 31st December 2020 were retro-spectively analysed.Their clinical and pathological data were collected.Multiple logistic regression analysis was conducted to identify risk factors for POI and to generate the nomogram prediction model.Predictive accuracy,discriminatory capability,and clinical usefulness were evaluated by cali-bration curves,concordance index(C-index),and decision curve analysis(DCA).Results:Multivari-ate regression analysis revealed that age,smoking,chronic respiratory diseases,laparoscopic surgery,intraoperative blood loss and lung function exercise compliance were independent prognos-tic factors for POI in GC patients.The nomogram had a Cindex of 0.878(95%CI:0.801~0.956).The calibration curves showed good consistency between actual and nomogram-predicted probabilities.The area under the curve(AUC)was 0.878,while the cutoff value was-2.088 with a sensitivity of 80.6%and a specifificity of 82.9%.DCA showed that the nomogram had better clinical usefulness.Conclusions:The present study provides a nomogram developed with perioperative features to predict the incidence of POI in GC patients.

2.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1045889

ABSTRACT

To analyze the association between exposure to air pollution and respiratory disease of primary school students in Chongqing City. Eight districts and counties were randomly selected based on the air pollution situation in Chongqing City. In each selected district and county, one primary school was randomly selected. A questionnaire survey was conducted on all primary school students in Grades 3-5 by the end of 2019. Air quality data from the nearest environmental monitoring sites were collected. A logistic regression model was used to analyze the impact of the living environment, lifestyle and air pollution on the respiratory disease of surveyed students. This study included 5 918 primary school students, with a prevalence rate of respiratory disease of 21.54%. The prevalence rates of boys and girls were 23.38% and 19.59%, respectively. The average Air quality index (AQI) of the surveyed school was 67, and the rates of exceeding standards of PM10, PM2.5, NO2 and O3 were 1.16%, 6.92%, 0.99% and 5.65%, respectively. The level of SO2 and CO did not exceed the standard. After adjusting for relevant factors, logistic regression analysis showed that primary school students in areas with high exposure to air pollution (OR=2.52), using air pollution related-chemicals at home (OR=1.47), passive smoking (OR=1.27), and keeping pets at home (OR=1.18) had a higher risk of respiratory disease (all P<0.05). In addition, the average annual values of AQI (OR=1.18), PM10 (OR=1.20), PM2.5 (OR=1.35), and NO2 (OR=1.11) increased the risk of respiratory diseases in primary school students (all P<0.05). In conclusion, the respiratory disease of primary school students in Chongqing City is related to the living environment, behavior habits and ambient air quality. The increased exposure concentration of PM10, PM2.5 and NO2 in air pollutants can lead to an increased risk of respiratory disease among primary school students.


Subject(s)
Female , Humans , Male , Child , Air Pollution/adverse effects , Nitrogen Dioxide , Particulate Matter , Respiratory Tract Diseases/epidemiology , Schools , Students
3.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1045936

ABSTRACT

Public exposure to radon has attracted increasing public concern. The newly issued "Standards for indoor air quality (GB/T 18883-2022)" has revised the radiological parameters of radon. This study analyzed and discussed the relevant technical contents about the derivation of radon limit, including the distribution level for indoor radon, exposure pathway, health effects, and the process for establishing the standard limits. Specific implementation and evaluation suggestions are also proposed.


Subject(s)
Humans , Radon/analysis , Air Pollution, Indoor , China , Housing
4.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1045937

ABSTRACT

The formulation and revision of the detection methods of indoor air quality standards is an important, rigorous and delicate endeavor. This paper introduced the formulation and revision of the detection methods of the standards for indoor air quality (GB/T 18883-2022), focusing on the revision process, revision principles, main adjustments and technical points of some key indicators to facilitate users to better understand and apply the detection methods in standards for indoor air quality (GB/T 18883-2022).


Subject(s)
Humans , Air Pollution, Indoor , China , Reference Standards , Air Pollutants/analysis
5.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1046212

ABSTRACT

To analyze the association between exposure to air pollution and respiratory disease of primary school students in Chongqing City. Eight districts and counties were randomly selected based on the air pollution situation in Chongqing City. In each selected district and county, one primary school was randomly selected. A questionnaire survey was conducted on all primary school students in Grades 3-5 by the end of 2019. Air quality data from the nearest environmental monitoring sites were collected. A logistic regression model was used to analyze the impact of the living environment, lifestyle and air pollution on the respiratory disease of surveyed students. This study included 5 918 primary school students, with a prevalence rate of respiratory disease of 21.54%. The prevalence rates of boys and girls were 23.38% and 19.59%, respectively. The average Air quality index (AQI) of the surveyed school was 67, and the rates of exceeding standards of PM10, PM2.5, NO2 and O3 were 1.16%, 6.92%, 0.99% and 5.65%, respectively. The level of SO2 and CO did not exceed the standard. After adjusting for relevant factors, logistic regression analysis showed that primary school students in areas with high exposure to air pollution (OR=2.52), using air pollution related-chemicals at home (OR=1.47), passive smoking (OR=1.27), and keeping pets at home (OR=1.18) had a higher risk of respiratory disease (all P<0.05). In addition, the average annual values of AQI (OR=1.18), PM10 (OR=1.20), PM2.5 (OR=1.35), and NO2 (OR=1.11) increased the risk of respiratory diseases in primary school students (all P<0.05). In conclusion, the respiratory disease of primary school students in Chongqing City is related to the living environment, behavior habits and ambient air quality. The increased exposure concentration of PM10, PM2.5 and NO2 in air pollutants can lead to an increased risk of respiratory disease among primary school students.


Subject(s)
Female , Humans , Male , Child , Air Pollution/adverse effects , Nitrogen Dioxide , Particulate Matter , Respiratory Tract Diseases/epidemiology , Schools , Students
6.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1046259

ABSTRACT

Public exposure to radon has attracted increasing public concern. The newly issued "Standards for indoor air quality (GB/T 18883-2022)" has revised the radiological parameters of radon. This study analyzed and discussed the relevant technical contents about the derivation of radon limit, including the distribution level for indoor radon, exposure pathway, health effects, and the process for establishing the standard limits. Specific implementation and evaluation suggestions are also proposed.


Subject(s)
Humans , Radon/analysis , Air Pollution, Indoor , China , Housing
7.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1046260

ABSTRACT

The formulation and revision of the detection methods of indoor air quality standards is an important, rigorous and delicate endeavor. This paper introduced the formulation and revision of the detection methods of the standards for indoor air quality (GB/T 18883-2022), focusing on the revision process, revision principles, main adjustments and technical points of some key indicators to facilitate users to better understand and apply the detection methods in standards for indoor air quality (GB/T 18883-2022).


Subject(s)
Humans , Air Pollution, Indoor , China , Reference Standards , Air Pollutants/analysis
8.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-307094

ABSTRACT

The tocopherol cyclase was one of the key enzymes in plant vitamin E biosynthesis pathway. According to the study of Carthamus tinctorius transcriptome data,the Tocopherol cyclase gene was obtained using RT-PCR techniques and named CtTC . Bioinformatics analysis showed theopen reading frame (ORF)of CtTC was 1 524 bp. The putative protein contained 507 amino acids with a predicted molecular mass of 62.9 kDa and theoretically isoelectric point was 5.01.Signal peptide analysis showed that it was a non secretory protein, and there was no signal peptide. The subcellular localization showed that the CtTC protein was located in the chloroplast. The expression of CtTC gene in safflower seeds at different development stages was determined by quantitative real-time PCR, it was found that the highest expression level of CtTC gene was detected in 50 DAF.Quantitative RT-PCR analysis suggested that expression of CtTC is induced and strengthened by drought stresses. This research provided a candidate gene for metabolic engineering of vitamin E and resisting stress.

SELECTION OF CITATIONS
SEARCH DETAIL