Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Malays J Pathol ; 44(2): 235-244, 2022 Aug.
Article in English | MEDLINE | ID: mdl-36043586

ABSTRACT

Chromosomal abnormality is one of the causes of congenital disorders among newborns. Despite aneuploidy being the major cause of first trimester miscarriages, very few aneuploidies such as trisomies of chromosomes 13, 18 and 21 survive to birth. The results of 4,064 patients referred for cytogenetic analysis at Human Genome Centre, Universiti Sains Malaysia, Kelantan, Malaysia between 2008 and 2019 were reviewed. We retrospectively investigated the karyotype patterns, clinical features and parental ages of the three common live-born autosomal trisomies such as trisomy 13, trisomy 18 and trisomy 21. The relative frequency of cases with the total sample received and cultured was calculated in each group and compared with those reported elsewhere. Between 2008 and 2019, a total of 1034 live-born trisomic cases which accounted for 25.4% of the 4064 total referred cases and 73.7% of 1403 suspected trisomy cases, were identified, with age ranging from newborns to 57 years. Down syndrome was the commonest aneuploidy (857 cases; 21.1%) followed by Edwards syndrome (133 cases; 3.3%) and Patau syndrome (44 cases; 1.1%). The number of diagnosed cases for each of the trisomies was fairly stable from year to year. About two-thirds of both maternal and paternal ages were ≥ 35 years. This is the first cytogenetic report on the common live-born autosomal trisomies in the North-Eastern region of Malaysia. The prevalence of trisomies 21 was found to be higher compared to an earlier study in the North-Western region of Malaysia, wherein also, advanced maternal age was a significant risk factor.


Subject(s)
Down Syndrome , Trisomy , Adult , Aneuploidy , Chromosomes, Human, Pair 13/genetics , Chromosomes, Human, Pair 18/genetics , Down Syndrome/diagnosis , Down Syndrome/epidemiology , Down Syndrome/genetics , Female , Humans , Infant, Newborn , Karyotype , Malaysia/epidemiology , Parents , Retrospective Studies , Trisomy/genetics , Trisomy 13 Syndrome
2.
Malays J Pathol ; 42(3): 307-321, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33361712

ABSTRACT

Chronic myeloid leukaemia (CML) provides an illustrative disease model for both molecular pathogenesis of cancer and rational drug therapy. Imatinib mesylate (IM), a BCR-ABL1 targeted tyrosine kinase inhibitor (TKI) drug, is the first line gold standard drug for CML treatment. Conventional cytogenetic analysis (CCA) can identify the standard and variant Philadelphia (Ph) chromosome, and any additional complex chromosome abnormalities at diagnosis as well as during treatment course. Fluorescence in situ hybridization (FISH) is especially important for cells of CML patients with inadequate or inferior quality metaphases or those with variant Ph translocations. CCA in conjunction with FISH can serve as powerful tools in all phases of CML including the diagnosis, prognosis, risk stratification and monitoring of cytogenetic responses to treatment. Molecular techniques such as reverse transcriptase-polymerase chain reaction (RT-PCR) is used for the detection of BCR-ABL1 transcripts at diagnosis whereas quantitative reverse transcriptase-polymerase chain reaction (qRTPCR) is used at the time of diagnosis as well as during TKI therapy for the quantitation of BCR-ABL1 transcripts to evaluate the molecular response and minimal residual disease (MRD). Despite the excellent treatment results obtained after the introduction of TKI drugs, especially Imatinib mesylate (IM), resistance to TKIs develops in approximately 35% - 40% of CML patients on TKI therapy. Since point mutations in BCR-ABL1 are a common cause of IM resistance, mutation analysis is important in IM resistant patients. Mutations are reliably detected by nested PCR amplification of the translocated ABL1 kinase domain followed by direct sequencing of the entire amplified kinase domain. The objective of this review is to highlight the importance of regular and timely CCA, FISH analysis and molecular testing in the diagnosis, prognosis, assessment of therapeutic efficacy, evaluation of MRD and in the detection of BCR-ABL1 kinase mutations which cause therapeutic resistance in adult CML patients.


Subject(s)
Cytogenetic Analysis/methods , Fusion Proteins, bcr-abl/analysis , Leukemia, Myelogenous, Chronic, BCR-ABL Positive/genetics , Molecular Targeted Therapy/methods , Reverse Transcriptase Polymerase Chain Reaction/methods , Antineoplastic Agents/therapeutic use , Drug Resistance, Neoplasm/genetics , Fusion Proteins, bcr-abl/genetics , Humans , Imatinib Mesylate/therapeutic use , In Situ Hybridization, Fluorescence , Leukemia, Myelogenous, Chronic, BCR-ABL Positive/drug therapy , Mutation , Protein Kinase Inhibitors/therapeutic use , Protein-Tyrosine Kinases/antagonists & inhibitors
3.
Malays Fam Physician ; 13(1): 10-17, 2018.
Article in English | MEDLINE | ID: mdl-29796205

ABSTRACT

INTRODUCTION: Cervical cancer ranks as the second most frequent cancer among women in Malaysia. Although a cervical screening program has been introduced since 1960s and is provided free of charge in all government health facilities, the coverage and adherence rate to recommendation among Malaysian women remains low. OBJECTIVES: To determine the proportion of non-adherence to Pap smear screening guidelines and its associated factors among women attending a health clinic in Malaysia. METHOD: A cross sectional study involving 316 women aged 20 to 65 years who had undergone a Pap smear. Universal sampling method was applied to select participants among women who attended the selected health clinic from January 2013 to May 2013. A self-administered questionnaire was used to obtain the socio-demographic characteristics, socio-health data and perceptions about cervical cancer and Pap smear screening. The data was analysed using descriptive statistics and multiple logistic regression. RESULT: The proportion of non-adherence to Pap smear screening was 90.5%. Age, marital status, duration of marriage, education level, employment, household income and number of children were not significantly associated with non-adherence. Perceived severity, perceived susceptibility, perceived benefit, perceived barrier and cues to action did not show significant association with non-adherence to Pap smear screening. CONCLUSION: Non-adherence to Pap smear screening was high among Malaysian women. Measures should be taken to increase Pap smear screening coverage in our country. Other factors beyond Health Belief Model that influence Pap smear screening practice among Malaysian women should be explored.

4.
J Oral Rehabil ; 44(5): 398-404, 2017 May.
Article in English | MEDLINE | ID: mdl-28295492

ABSTRACT

This study aimed to investigate residual ridge resorption (RRR) of anterior and posterior maxillary and mandibular edentulous ridges, in patients treated with mandibular implant overdentures (IOD) and compare with conventional complete denture (CD) wearers, and to determine at each location, the association of RRR with the occlusal forces distribution and other patients' variables. The anterior and posterior RRR of IOD (six males, 17 females) and CD (12 males, 11 females) groups were determined using baseline and follow-up dental panaromic radiographs (DPT) (mean intervals 4 ± 1·8 years). The bone ratios were calculated using proportional area: anatomic to fixed reference areas and mean difference of ratios between the intervals determined RRR. The ridge locations included anterior and posterior maxillary and posterior mandibular arches. The T-Scan III digital occlusal system was used to record anterior and posterior percentage occlusal force (%OF) distributions. There were significant differences in anterior and posterior %OF between treatment groups. Two-way anova showed RRR was significant for arch locations (P = 0·005), treatment group (IOD versus CD) (P = 0·001), however, no significant interaction (P = 0·799). Multivariate regression analyses showed significant association between RRR and %OF at anterior maxilla (P = 0·000) and posterior mandible (P = 0·023) and for treatment groups at posterior maxilla (P = 0·033) and mandibular areas (P = 0·021). Resorption was observed in IOD compared to CD groups, with 8·5% chance of less resorption in former and 7·8% in the latter location. Depending on arch location, ridge resorption at various locations was associated with occlusal force distribution and/or treatment groups (implant prostheses or conventional complete dentures).


Subject(s)
Alveolar Bone Loss/etiology , Dental Prosthesis, Implant-Supported/instrumentation , Denture, Complete, Lower , Denture, Complete, Upper , Denture, Overlay/adverse effects , Jaw, Edentulous/surgery , Mandible/pathology , Maxilla/pathology , Aged , Alveolar Bone Loss/diagnostic imaging , Bite Force , Denture Retention , Female , Humans , Malaysia , Male , Mandible/diagnostic imaging , Maxilla/diagnostic imaging , Middle Aged , Radiography
5.
Aust Dent J ; 61(2): 208-18, 2016 06.
Article in English | MEDLINE | ID: mdl-25966305

ABSTRACT

BACKGROUND: Short dental implants can be an alternative to bone augmentation procedures at sites of reduced alveolar bone. Most studies on short implants are retrospective or multicentre reports that lack controlled and consistent comparison between different systems. This study aimed to compare clinical and radiographic outcomes of short implants in two different systems in the posterior mandible. METHODS: Twenty patients with two adjacent missing posterior teeth were recruited. Patients were assigned equally and randomly into two groups; Bicon(®) (6 or 8 mm) and Ankylos(®) (8 mm) implants. A two-stage surgical approach and single crowns were used for implant placement and loading. Outcomes included peri-implant clinical parameters, implant stability (Periotest values; PTVs) and peri-implant bone changes, which were assessed at baseline, 2, 6 and 12 months post-loading. RESULTS: No implant loss was encountered up to 12 months post-loading. No significant difference in the clinical or radiographic parameters was observed except for PTVs (p < 0.05) that was lower in Ankylos(®) implants. CONCLUSIONS: The use of short dental implants was associated with excellent 12 months clinical and radiographic outcomes. Ankylos(®) and Bicon(®) implants demonstrated similar peri-implant soft tissue and alveolar bone changes. However, Ankylos(®) implants demonstrated better implant stability at all evaluation intervals.


Subject(s)
Alveolar Bone Loss/surgery , Dental Implantation, Endosseous/methods , Dental Implants , Dental Prosthesis, Implant-Supported , Mandible/surgery , Adult , Aged , Analysis of Variance , Crowns , Dental Prosthesis Design , Dental Restoration Failure/statistics & numerical data , Female , Humans , Male , Middle Aged , Retrospective Studies
6.
J Oral Rehabil ; 32(1): 65-71, 2005 Jan.
Article in English | MEDLINE | ID: mdl-15634304

ABSTRACT

Nylon denture base material could be a useful alternative to poly (methyl methacrylate) (PMMA) in special circumstances such as patient allergy to the monomer. The aim of this study was to evaluate the flexural properties of a nylon denture base material (Lucitone FRS), a conventional compression-moulded heat-polymerized (Meliodent), a compression-moulded microwave-polymerized (Acron MC) and an injection-moulded microwave-polymerized (Lucitone 199) PMMA polymers. The effect of aldehyde-free, oxygen releasing disinfectant solution (Perform) on these properties was also investigated. The flexural modulus and the flexural strength were assessed with a three-point bending test. Specimens were stored in water at a temperature of 37 degrees C for 30 days. For each material, half of the prepared specimens were randomly selected and immersed in the disinfectant 24 h prior to testing. Results were compared statistically at a confidence level of 95%. The result showed that in both the control and disinfected groups, the flexural modulus of nylon was significantly lower than the three PMMA polymers. The flexural strength of nylon was significantly lower than those of Meliodent and Acron MC but was comparable with Lucitone 199. A 24-h immersion in the disinfecting solution increased the rigidity of nylon denture base material.


Subject(s)
Acrylic Resins/chemistry , Denture Bases , Dental Disinfectants/pharmacology , Hardness/drug effects , Humans , Materials Testing/methods , Pliability/drug effects , Polymethyl Methacrylate/chemistry
7.
Int J Prosthodont ; 14(3): 214-8, 2001.
Article in English | MEDLINE | ID: mdl-11484567

ABSTRACT

PURPOSE: The impact strength and the flexural properties of denture base materials are of importance in predicting their clinical performance upon sudden loading. This study compares the impact and transverse strengths and the flexural modulus of three denture base polymers. MATERIALS AND METHODS: The investigation included a relatively new microwave-polymerized polyurethane-based denture material processed by an injection-molding technique, a conventional microwave-polymerized denture material, and a heat-polymerized compression-molded poly(methyl methacrylate) (PMMA) denture material. Impact strength was determined using a Charpy-type impact tester. The transverse strength and the flexural modulus were assessed with a three-point bending test. The results were subjected to statistical analysis using a one-way analysis of variance and the Scheffé test for comparison. RESULTS: The impact strength of the microwave-polymerized injection-molded polymer was 6.3 kl/m2, while its flexural strength was 66.2 MPa. These values were lower than those shown by the two compression-molded PMMA-based polymers. The differences were statistically significant. The flexural modulus of the new denture material was 2,832 MPa, which was higher than the conventional heat-polymerized polymer but was comparable to the other microwave-polymerized PMMA-based polymer. The difference in the flexural modulus was statistically significant. CONCLUSION: In terms of the impact and flexural strengths, the new microwave-polymerized, injection-molded, polyurethane-based polymer offered no advantage over the existing heat- and microwave-polymerized PMMA-based denture base polymers. However, it has a rigidity comparable to that of the microwave-polymerized PMMA polymer.


Subject(s)
Dental Materials/chemistry , Denture Bases , Polymers/chemistry , Acrylic Resins/chemistry , Acrylic Resins/radiation effects , Analysis of Variance , Chemical Phenomena , Chemistry, Physical , Dental Materials/radiation effects , Elasticity , Hardness , Humans , Injections , Materials Testing , Methylmethacrylates/chemistry , Methylmethacrylates/radiation effects , Microwaves , Pliability , Polymers/radiation effects , Polymethyl Methacrylate/chemistry , Polymethyl Methacrylate/radiation effects , Polyurethanes/chemistry , Polyurethanes/radiation effects , Pressure , Statistics as Topic , Stress, Mechanical
8.
J Prosthet Dent ; 85(6): 540-3, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11404753

ABSTRACT

This article describes the occlusal rehabilitation of a partially edentulous patient who did not want a removable partial denture. Implants and extensive fixed restorations were used to restore posterior support and treat severely worn dentition, respectively. The treatment offered the patient a functional and esthetic result.


Subject(s)
Dental Implants , Jaw, Edentulous, Partially/rehabilitation , Aged , Crowns , Dental Abutments , Dental Implantation, Endosseous , Dental Occlusion, Centric , Dental Veneers , Denture, Partial, Fixed , Esthetics, Dental , Follow-Up Studies , Humans , Jaw, Edentulous, Partially/surgery , Male , Malocclusion/rehabilitation , Mandible/surgery , Mouth Rehabilitation , Post and Core Technique , Tooth Abrasion/rehabilitation , Tooth Attrition/rehabilitation , Vertical Dimension
9.
J Oral Rehabil ; 21(6): 641-8, 1994 Nov.
Article in English | MEDLINE | ID: mdl-7830199

ABSTRACT

The degree of polymerization of an acrylic resin repair material, as established by residual monomer estimation, was compared using three different polymerization methods, i.e. bench-cure, hydroflask-cure and microwave irradiation cure. The repair strength of a conventional heat-polymerized resin was then assessed following repairs using each of these three methods. The lowest level of residual monomer was achieved with the microwave irradiation cure. It was also demonstrated that of the three methods, polymerization using microwave energy resulted in the strongest repair.


Subject(s)
Denture Bases , Denture Repair/methods , Methylmethacrylates/chemistry , Microwaves , Analysis of Variance , Dental Bonding/methods , Elasticity , Materials Testing , Methylmethacrylates/radiation effects , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL
...