Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Chromatogr Sci ; 50(9): 763-8, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22647394

ABSTRACT

A selective, sensitive and stability-indicating reversed-phase high-performance liquid chromatography method was developed and validated for the determination of clarithromycin antibiotic in human plasma. Liquid chromatography was performed on a 5-µm (100 × 4.6 mm) C8 column at 40°C. The mobile phase consisted of acetonitrile with 0.045M H(3)PO(4) (37:63, v/v) adjusted to pH 6.7 and pumped at a flow rate of 1.2 mL/min. Detections were monitored on an electrochemical detector operated at a potential of 0.85 V with glassy carbon electrode against Ag/AgCl reference electrode. Each analysis required 13 min and quantification over the range of 0.05-5.0 µg/mL of plasma was linear, as indicated by a correlation coefficient (R(2)), 0.9999. The method was validated according to international guidelines. Data with respect to accuracy, within-run and between run, were close to 100% with 4% precision. Absolute recovery was 95%. The limit of quantification was 0.05 µg/mL. Neither endogenous substances nor commonly used drugs were found to interfere with the retention times of analytes. Stock solutions and calibration standards of the drug and quality control preparations were demonstrated to be stable at room temperature and -20°C for long and short periods of time. Eventually, the proposed method was successfully applied to quantify clarithromycin in spiked human plasma and real samples from healthy volunteers, indicating the utility and throughput of this method for clinical and bioavailability studies.


Subject(s)
Chromatography, High Pressure Liquid/methods , Clarithromycin/blood , Electrochemical Techniques/methods , Chromatography, Reverse-Phase , Clarithromycin/chemistry , Clarithromycin/pharmacokinetics , Drug Stability , Humans , Least-Squares Analysis , Reproducibility of Results , Sensitivity and Specificity
2.
Anal Bioanal Chem ; 382(1): 223-30, 2005 May.
Article in English | MEDLINE | ID: mdl-15900476

ABSTRACT

A rapid, sensitive and selective liquid chromatography-mass spectrometry (LC-MS) assay has been developed for determination of cyclosporin A (CyA) in human plasma; cyclosporin B (CyB) was used as internal standard (IS). The method utilized a combination of a column-switching valve and a reversed-phase symmetry column. The mobile phase was a 25:75 (v/v) mixture of 10% aqueous glacial acetic acid and acetonitrile. Running time per single run was less than 10 min. Sample preparation included C8 SPE of human plasma spiked with the analyte and internal standard, evaporation of the eluate to dryness at 50 degrees C under N2 gas, and finally reconstitution in the mobile phase. Detection of cyclosporin A and the IS was performed in selected ion-monitoring mode at m/z 601.3 and 594.4 Da for CyA and IS, respectively. Quantitation was achieved by use of the regression equation of relative peak area of cyclosporin to IS against concentration of cyclosporin. The method was validated according to FDA guideline requirements. The linearity of the assay in the range 5.0-400.0 ng mL(-1) was verified as characterized by the least-squares regression line Y = (0.00268+/-1.9 x 10(-4))X+(0.00078+/-1.8 x 10(-3)), correlation coefficient, r = 0.9986+/-1.1 x 10(-3) (n = 48). Intra and inter-day quality-control measurements in the range 5.0-350.0 ng mL(-1) revealed almost 100% accuracy and < or = 9% CV for precision. The mean absolute recovery of CyA was found to be 84.01+/-9.9% and the respective relative recovery was 100.3+/-9.19. The limit of quantitation (LOQ) achieved was 5 ng mL(-1). Eventually, stability testing of the analyte and IS in plasma or stock solution revealed that both chemicals were very stable when stored for long or short periods of time at room temperature or -20 degrees C.


Subject(s)
Chromatography, Liquid/methods , Cyclosporine/blood , Spectrometry, Mass, Electrospray Ionization/methods , Humans , Quality Control , Reference Standards , Reproducibility of Results , Sensitivity and Specificity
3.
J Pharm Biomed Anal ; 22(5): 739-44, 2000 Jun.
Article in English | MEDLINE | ID: mdl-10815716

ABSTRACT

The development and evaluation of HPLC method for quantifying cetirizine in human serum is described. The method involves liquid phase extraction of cetirizine in methylene chloride, adding diazepam as an internal standard, followed by separation on a reversed phase C18 Novapak column (150 x 3.9 nm; 4 microm), and employing a UV-detection set at 230 nm at ambient temperature. The mobile phase consists of a 13 mM phosphoric acid solution and acetonitrile (61:39 v/v) adjusted to pH 2.8 with 5 M NaOH. The assay is linear from 10 to 500 ng ml(-1) with a detection limit of 5 ng ml(-1) and a mean recovery of 96.5%. The applicability of this method in pharmacokinetic studies is evaluated.


Subject(s)
Cetirizine/blood , Chromatography, High Pressure Liquid/methods , Histamine H1 Antagonists/blood , Cetirizine/pharmacokinetics , Histamine H1 Antagonists/pharmacokinetics , Humans , Reproducibility of Results , Sensitivity and Specificity , Spectrophotometry, Ultraviolet
SELECTION OF CITATIONS
SEARCH DETAIL
...