Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chim Acta ; 914: 75-80, 2016 Mar 31.
Article in English | MEDLINE | ID: mdl-26965329

ABSTRACT

A novel fluidized beads strategy for utilization of particle-immobilized reagents in flow analysis was developed in this study. The performance of the suggested strategy was demonstrated by the determination of glycerol in biodiesel. This analytical task was used as a proof-of-concept example. The method is based on on-line extraction of glycerol from biodiesel into aqueous stationary phase of extraction-chromatographic column, followed by elution and spectrophotometric determination in the form of copper glycerate formed in a fluidized reactor of stepwise injection system. The floating of cation exchange resin Dowex(®) 50WX4, saturated with Cu(II) ions in liquid phase, was accomplished by air-bubbling. The linear range was from 100 to 1000 mg kg(-1), and the limit of detection, calculated as 3s of a blank test (n = 5), was found to be 30 mg kg(-1). The method was successfully applied to the analysis of biodiesel and biodiesel-blend (B 20) samples.


Subject(s)
Biofuels/analysis , Glycerol/analysis , Gas Chromatography-Mass Spectrometry
2.
Talanta ; 148: 666-72, 2016 Feb 01.
Article in English | MEDLINE | ID: mdl-26653499

ABSTRACT

A novel vapor permeation-stepwise injection (VP-SWI) method for the determination of methanol and ethanol in biodiesel samples is discussed. In the current study, stepwise injection analysis was successfully combined with voltammetric detection and vapor permeation. This method is based on the separation of methanol and ethanol from a sample using a vapor permeation module (VPM) with a selective polymer membrane based on poly(phenylene isophtalamide) (PA) containing high amounts of a residual solvent. After the evaporation into the headspace of the VPM, methanol and ethanol were transported, by gas bubbling, through a PA membrane to a mixing chamber equipped with a voltammetric detector. Ethanol was selectively detected at +0.19 V, and both compounds were detected at +1.20 V. Current subtractions (using a correction factor) were used for the selective determination of methanol. A linear range between 0.05 and 0.5% (m/m) was established for each analyte. The limits of detection were estimated at 0.02% (m/m) for ethanol and methanol. The sample throughput was 5 samples h(-1). The method was successfully applied to the analysis of biodiesel samples.


Subject(s)
Biofuels/analysis , Ethanol/analysis , Methanol/analysis , Tandem Mass Spectrometry/methods , Flow Injection Analysis/methods , Permeability , Volatilization
SELECTION OF CITATIONS
SEARCH DETAIL
...