Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Orthop Surg Res ; 18(1): 742, 2023 Sep 30.
Article in English | MEDLINE | ID: mdl-37777776

ABSTRACT

BACKGROUND: Custom-made implants are a valid option in revision total hip arthroplasty to address massive acetabular bone loss. The aim of this study was to assess the accuracy of custom-made acetabular implants between preoperative planning and postoperative positioning using CT scans. METHODS: In a retrospective analysis, three patients who underwent an acetabular custom-made prosthesis were identified. The custom-made designs were planned through 3D CT analysis considering surgical points of attention. The accuracy of intended implants positioning was assessed by comparing pre- and postoperative CT analyzing the center of rotation (CoR), anteversion, inclination, screws, and implant surface in contact with the bone. RESULTS: The three cases presented satisfactory accuracy in positioning. A malpositioning in the third case was observed due to the posterization of the CoR of the implant of more than 10 mm. The other CoR vectors considered in the third patient and all vectors in the other two cases fall within 10 mm. All the cases were positioned with a difference of less than 10° of anteversion and inclination with respect to the planning. CONCLUSIONS: The current case series revealed promising accuracy in the positioning of custom-made acetabular prosthesis comparing the planned implant in preoperative CT with postoperative CT.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Retrospective Studies , Arthroplasty, Replacement, Hip/methods , Reoperation , Acetabulum/diagnostic imaging , Acetabulum/surgery , Tomography, X-Ray Computed
2.
J Clin Med ; 12(5)2023 Feb 24.
Article in English | MEDLINE | ID: mdl-36902607

ABSTRACT

The use of tricalcium phosphate (TCP) as a bone substitute is gaining increasing interest to treat severe acetabular bone defects in revision total hip arthroplasty (rTHA). The aim of this study was to investigate the evidence regarding the efficacy of this material. A systematic review of the literature was performed according to the PRISMA and Cochrane guidelines. The study quality was assessed using the modified Coleman Methodology Score (mCMS) for all studies. A total of eight clinical studies (230 patients) were identified: six on TCP used as biphasic ceramics composed of TCP and hydroxyapatite (HA), and two as pure-phase ceramics consisting of TCP. The literature analysis showed eight retrospective case series, of which only two were comparative studies. The mCMS showed an overall poor methodology (mean score 39.5). While the number of studies and their methodology are still limited, the available evidence suggests safety and overall promising results. A total of 11 cases that underwent rTHA with a pure-phase ceramic presented satisfactory clinical and radiological outcomes at initial short-term follow-up. Further studies at long-term follow-up, involving a larger number of patients, are needed before drawing more definitive conclusions on the potential of TCP for the treatment of patients who undergo rTHA.

3.
J Clin Med ; 11(22)2022 Nov 10.
Article in English | MEDLINE | ID: mdl-36431138

ABSTRACT

The use of orthobiologics is gaining increasing interest as a minimally invasive treatment for hip osteoarthritis (OA). The aim of this study was to investigate the evidence about the safety and efficacy of these products. A systematic review of the literature was performed according to the PRISMA and Cochrane guidelines. The study quality was assessed using the RoB 2.0 for randomized controlled trials (RCTs) and the modified Coleman Methodology Score (mCMS) for all studies. A total of 20 clinical studies (735 patients) was identified, 12 on PRP injections and eight on cell-based therapies (five from bone marrow, two from adipose tissue, and one from amniotic fluid). The publication trend increased over time, with over 50% of articles published from 2019. The literature analysis showed only six RCTs, all on PRP injections. The mCMS showed an overall fair methodology (mean score 59.4). While the number of studies and their methodology are still limited, the available evidence suggests safety and overall promising results, with the treatment success being inversely proportional to the severity of OA. Further high-level controlled trials are needed before drawing more definitive conclusions on the real potential of orthobiologics for the injective treatment of patients affected by hip OA.

SELECTION OF CITATIONS
SEARCH DETAIL
...