Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Microdevices ; 25(2): 11, 2023 03 16.
Article in English | MEDLINE | ID: mdl-36928445

ABSTRACT

Microengineering technologies provide bespoke tools for single-cell studies, including microarray approaches. There are many challenges when culturing adherent single cells in confined geometries for extended periods, including the ability of migratory cells to overcome confining cell-repellent surfaces with time. Following studies suggesting clonal expansion of only a few vascular smooth muscle cells (vSMCs) contributes to plaque formation, the investigation of vSMCs at the single-cell level is central to furthering our understanding of atherosclerosis. Herein, we present a medium throughput cellular microarray, for the tracking of single, freshly-isolated vSMCs as they undergo phenotypic modulation in vitro. Our solution facilitates long-term cell confinement (> 3 weeks) utilising novel application of surface functionalisation methods to define individual culture microwells. We demonstrate successful tracking of hundreds of native vSMCs isolated from rat aortic and carotid artery tissue, monitoring their proliferative capacity and uptake of oxidised low-density lipoprotein (oxLDL) by live-cell microscopy. After 7 days in vitro, the majority of viable SMCs remained as single non-proliferating cells (51% aorta, 78% carotid). However, a sub-population of vSMCs demonstrated high proliferative capacity (≥ 10 progeny; 18% aorta, 5% carotid), in line with reports that a limited number of medial SMCs selectively expand to populate atherosclerotic lesions. Furthermore, we show that, when exposed to oxLDL, proliferative cells uptake higher levels of lipoproteins, whilst also expressing greater levels of galectin-3. Our microwell array approach enables long-term characterisation of multiple phenotypic characteristics and the identification of new cellular sub-populations in migratory, proliferative adherent cell types.


Subject(s)
Atherosclerosis , Myocytes, Smooth Muscle , Single-Cell Analysis , Tissue Array Analysis , Animals , Rats , Aorta , Atherosclerosis/metabolism , Atherosclerosis/pathology , Carotid Arteries , Cells, Cultured , Myocytes, Smooth Muscle/metabolism , Single-Cell Analysis/instrumentation , Single-Cell Analysis/methods , Tissue Array Analysis/instrumentation , Tissue Array Analysis/methods
2.
Lab Chip ; 22(10): 1989-2000, 2022 05 17.
Article in English | MEDLINE | ID: mdl-35466333

ABSTRACT

Disorders of the central nervous system (CNS) represent a global health challenge and an increased understanding of the CNS in both physiological and pathophysiological states is essential to tackle the problem. Modelling CNS conditions is difficult, as traditional in vitro models fail to recapitulate precise microenvironments and animal models of complex disease often have limited translational validity. Microfluidic and organ-on-chip technologies offer an opportunity to develop more physiologically relevant and complex in vitro models of the CNS. They can be developed to allow precise cellular patterning and enhanced experimental capabilities to study neuronal function and dysfunction. To improve ease-of-use of the technology and create new opportunities for novel in vitro studies, we introduce a modular platform consisting of multiple, individual microfluidic units that can be combined in several configurations to create bespoke culture environments. Here, we report proof-of-concept experiments creating complex in vitro models and performing functional analysis of neuronal activity across modular interfaces. This platform technology presents an opportunity to increase our understanding of CNS disease mechanisms and ultimately aid the development of novel therapies.


Subject(s)
Microfluidic Analytical Techniques , Neurosciences , Animals , Microfluidics
3.
Lab Chip ; 21(12): 2306-2329, 2021 06 15.
Article in English | MEDLINE | ID: mdl-34085677

ABSTRACT

Immunotherapy is a powerful and targeted cancer treatment that exploits the body's immune system to attack and eliminate cancerous cells. This form of therapy presents the possibility of long-term control and prevention of recurrence due to the memory capabilities of the immune system. Various immunotherapies are successful in treating haematological malignancies and have dramatically improved outcomes in melanoma. However, tackling other solid tumours is more challenging, mostly because of the immunosuppressive tumour microenvironment (TME). Current in vitro models based on traditional 2D cell monolayers and animal models, such as patient-derived xenografts, have limitations in their ability to mimic the complexity of the human TME. As a result, they have inadequate translational value and can be poorly predictive of clinical outcome. Thus, there is a need for robust in vitro preclinical tools that more faithfully recapitulate human solid tumours to test novel immunotherapies. Microfluidics and lab-on-a-chip technologies offer opportunities, especially when performing mechanistic studies, to understand the role of the TME in immunotherapy, and to expand the experimental throughput when using patient-derived tissue through its miniaturization capabilities. This review first introduces the basic concepts of immunotherapy, presents the current preclinical approaches used in immuno-oncology for solid tumours and then discusses the underlying challenges. We provide a rationale for using microfluidic-based approaches, highlighting the most recent microfluidic technologies and methodologies that have been used for studying cancer-immune cell interactions and testing the efficacy of immunotherapies in solid tumours. Ultimately, we discuss achievements and limitations of the technology, commenting on potential directions for incorporating microfluidic technologies in future immunotherapy studies.


Subject(s)
Melanoma , Neoplasms , Animals , Humans , Immunotherapy , Lab-On-A-Chip Devices , Microfluidics , Neoplasms/therapy , Tumor Microenvironment
4.
Biosens Bioelectron ; 24(5): 1235-40, 2009 Jan 01.
Article in English | MEDLINE | ID: mdl-18760585

ABSTRACT

In recent years, protein array technologies have found widespread applications in proteomics. However, new methods for high-throughput analysis of protein-protein and protein-compound interactions are still required. In this paper, an array of lipid bilayer membranes formed within a microfluidic system with integrated electrodes is presented. The system is comprised of three layers that are clamped together, thus rendering the device cleanable and reusable. The device microfluidics enable the simultaneous formation of an array of lipid bilayers using a previously developed air-exposure technique, thereby avoiding the need to manually form individual bilayers. The Ag/AgCl electrodes allow for ion channel measurements, each of the sites being independently addressable. Typically, a 50% yield in simultaneous lipid bilayer formation over 12 sites was obtained and ion channel recordings have been acquired over multiple sites. This system has great potential for the development of an automatable platform of suspended lipid bilayer arrays.


Subject(s)
Biosensing Techniques/instrumentation , Electrochemistry/instrumentation , Lipid Bilayers/chemistry , Microfluidic Analytical Techniques/instrumentation , Patch-Clamp Techniques/methods , Protein Array Analysis/instrumentation , Protein Interaction Mapping/instrumentation , Biosensing Techniques/methods , Electrochemistry/methods , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity
5.
IEE Proc Nanobiotechnol ; 153(2): 21-30, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16671820

ABSTRACT

The study of ion channels and other membrane proteins and their potential use as biosensors and drug screening targets require their reconstitution in an artificial membrane. These applications would greatly benefit from microfabricated devices in which stable artificial lipid bilayers can be rapidly and reliably formed. However, the amount of protein delivered to the bilayer must be carefully controlled. A vesicle fusion technique is investigated where composite ion channels of the polyene antibiotic nystatin and the sterol ergosterol are employed to render protein-carrying vesicles fusogenic. After fusion with an ergosterol-free artificial bilayer, the nystatin-ergosterol channels do not dissociate immediately and thus cause a transient current signal that marks the vesicle fusion event. Experimental pitfalls of this method were identified, the influence of the nystatin and ergosterol concentration on the fusion rate and the shape of the fusion event marker was explored, and the number of different lipid species was reduced. Under these conditions, the -amyloid peptide could be delivered in a controlled manner to a standard planar bilayer. Additionally, electrical recordings were obtained of vesicles fusing with a planar lipid bilayer in a microfabricated device, demonstrating the suitability of nystatin-ergosterol modulated vesicle fusion for protein delivery within microsystems.


Subject(s)
Amyloid beta-Peptides/chemistry , Ergosterol/chemistry , Lipid Bilayers/chemistry , Liposomes/chemistry , Membrane Fusion , Membrane Proteins/chemistry , Nystatin/chemistry , Delayed-Action Preparations/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...