Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Card Surg ; 28(6): 770-5, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24118109

ABSTRACT

BACKGROUND: Continuous flow left ventricular assist devices (CF LVAD) are being implanted with increasing frequency for end-stage heart failure. At the time of LVAD implant, a large proportion of patients have pulmonary hypertension, right ventricular (RV) dysfunction, and tricuspid regurgitation (TR). RV dysfunction and TR can exacerbate renal dysfunction, hepatic dysfunction, coagulopathy, edema, and even prohibit isolated LVAD implant. Repairing TR mandates increased cardiopulmonary bypass time and bicaval cannulation, which should be reserved for the time of orthotopic heart transplantation. We hypothesized that CF LVAD implant would improve pulmonary artery pressures, enhance RV function, and minimize TR, obviating need for surgical tricuspid repair. METHODS: One hundred fourteen continuous flow LVADs implanted from 2005 through 2011 at a single center, with medical management of functional TR, were retrospectively analyzed. Pulmonary artery pressures were measured immediately prior to and following LVAD implant. RV function and TR were graded according to standard echocardiographic criteria, prior to, immediately following, and long-term following LVAD. RESULTS: There was a significant improvement in post-VAD mean pulmonary arterial pressures (26.6 ± 4.9 vs. 30.2 ± 7.4 mmHg, p = 0.008) with equivalent loading pressures (CVP = 12.0 ± 4.0 vs. 12.1 ± 5.1 p = NS). RV function significantly improved, as noted by right ventricular stroke work index (7.04 ± 2.60 vs. 6.05 ± 2.54, p = 0.02). There was an immediate improvement in TR grade and RV function following LVAD implant, which was sustained long term. CONCLUSION: Continuous flow LVAD implant improves pulmonary hypertension, RV function, and tricuspid regurgitation. TR may be managed nonoperatively during CF LVAD implant.


Subject(s)
Heart Failure/complications , Heart Failure/therapy , Heart-Assist Devices , Hypertension, Pulmonary/etiology , Hypertension, Pulmonary/therapy , Tricuspid Valve Insufficiency/etiology , Tricuspid Valve Insufficiency/therapy , Ventricular Dysfunction, Right/etiology , Ventricular Dysfunction, Right/therapy , Aged , Arterial Pressure , Female , Heart Failure/physiopathology , Heart Ventricles/physiopathology , Humans , Hypertension, Pulmonary/physiopathology , Male , Pulmonary Artery/physiopathology , Retrospective Studies , Stroke Volume , Treatment Outcome , Tricuspid Valve Insufficiency/physiopathology , Ventricular Dysfunction, Right/physiopathology , Ventricular Function, Right
SELECTION OF CITATIONS
SEARCH DETAIL
...