Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Publication year range
1.
Rev. cuba. estomatol ; 60(1)mar. 2023.
Article in Spanish | LILACS, CUMED | ID: biblio-1521909

ABSTRACT

Introducción: La fijación de las restauraciones indirectas es uno de los pasos más importantes, para conseguir una adecuada retención y sellado de la interfase entre el material restaurador y el diente. Objetivo: Evaluar la resistencia de unión al cizallamiento de diferentes agentes de fijación a dos aleaciones metálicas utilizadas en odontología. Métodos: Estudio experimental in vitro. Cien especímenes de aleaciones de metales base, 50 de níquel-cromo y 50 de níquel-cromo-titanio fueron preparados y divididos de manera aleatoria en 5 grupos. Esta división se realizó acorde con el agente de fijación utilizado: sistema autograbante de dos pasos (Clearfil SE Bond; CSB), sistema adhesivo universal (Single Bond Universal; SBU), cemento resinoso autoadhesivo (Maxcem Elite; ME), ionómero de vidrio (IV) y fosfato de zinc (ZnPO). Posteriormente a la aplicación de cada agente de fijación, los especímenes tratados fueron almacenados en agua destilada por 24 h a 37 ºC y sometidos a un ensayo de resistencia de unión al cizallamiento. Resultados: La resistencia de unión al cizallamiento fue influenciada significativamente por el tipo de agente de fijación (p = 0,002) y el tipo de aleación utilizada (p < 0,001). La resistencia de unión al cizallamiento fue mayor, al utilizar el sistema Clearfil SE Bond, seguida de Single Bond Universal; las diferencias entre Maxcem Elite y el Fosfato de zinc no fueron significativas. Finalmente, el IV no mostró adhesión a ninguna de las aleaciones metálicas utilizadas. Conclusiones: El uso de Clearfil SE Bond aumentó la resistencia de unión de los cementos resinosos a las aleaciones metálicas(AU)


Introduction: The bonding of indirect restorations is one of the most important steps, in order to achieve adequate retention and sealing of the interface between the restorative material and the tooth. Objective: To evaluate the shear bond strength of different bonding agents to two metal alloys used in dentistry. Methods: In vitro experimental study. One hundred specimens of base metal alloys, 50 nickel-chromium and 50 nickel-chromium-titanium were prepared and randomly divided into 5 groups. This division was made according to the bonding agent used: two-step self-etching system (Clearfil SE Bond; CSB), universal adhesive system (Single Bond Universal; SBU), self-adhesive resin cement (Maxcem Elite; ME), glass ionomer (IV) and zinc phosphate (ZnPO). After the application of each bonding agent, the treated specimens were stored in distilled water for 24 hr at 37 ºC and subjected to a shear bond strength test. Results: Shear bond strength was significantly influenced by the type of bonding agent (p = 0.002) and the type of alloy used (p < 0.001). Shear bond strength was highest when using the Clearfil SE Bond system, followed by Single Bond Universal; the differences between Maxcem Elite and Zinc Phosphate were not significant. Finally, IV did not show adhesion to any of the metal alloys used. Conclusions: The use of Clearfil SE Bond increased the bond strength of resinous cements to metallic alloys(AU)


Subject(s)
Humans , Dental Bonding/methods , Dental Cementum
2.
J Adv Prosthodont ; 15(6): 315-332, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38205120

ABSTRACT

PURPOSE: This study aimed to investigate whether the accuracy of intraoral scanners is influenced by different scanning strategies in an in vitro setting, through a systematic review and meta-analysis. MATERIALS AND METHODS: This review was conducted in accordance with the PRISMA 2020 standard. The following PICOS approach was used: population, tooth impressions; intervention, the use of intraoral scanners with scanning strategies different from the manufacturer's instructions; control, the use of intraoral scanners following the manufacturers' requirements; outcome, accuracy of intraoral scanners; type of studies, in vitro. A comprehensive literature search was conducted across various databases including Embase, SciELO, PubMed, Scopus, and Web of Science. The inclusion criteria were based on in vitro studies that reported the accuracy of digital impressions using intraoral scanners. Analysis was performed using Review Manager software (version 5.3.5; Cochrane Collaboration, Copenhagen, Denmark). Global comparisons were made using a standardized mean difference based on random-effect models, with a significance level of α = 0.05. RESULTS: The meta-analysis included 15 articles. Digital impression accuracy significantly improved under dry conditions (P < 0.001). Moreover, trueness and precision were enhanced when artificial landmarks were used (P ≤ 0.02) and when an S-shaped pattern was followed (P ≤ 0.01). However, the type of light used did not have a significant impact on the accuracy of the digital intraoral scanners (P ≥ 0.16). CONCLUSION: The accuracy of digital intraoral scanners can be enhanced by employing scanning processes using artificial landmarks and digital impressions under dry conditions.

3.
Bioengineering (Basel) ; 9(8)2022 Jul 27.
Article in English | MEDLINE | ID: mdl-36004871

ABSTRACT

Tooth wear is considered a well-developed issue in daily clinical practice; however, there is no standard protocol for treatment. The aim of this manuscript was to systematically review the literature to evaluate the clinical outcomes of direct or indirect restorations for treating tooth wear. A literature search was conducted through the PubMed MedLine, Scopus, ISI Web of Science, Scielo, and EMBASE databases up to 29 April 2022. Clinical studies evaluating the clinical performance of direct or indirect restorations for treating tooth wear for a minimum follow-up of 6 months were included in the review. A total of 2776 records were obtained from the search databases. After full-text reading, 16 studies were included in the qualitative analysis. Considering the high heterogenicity of the studies included, a meta-analysis could not be performed. All studies included the rehabilitation of anterior and posterior teeth with extensive wear, using both indirect and direct restorations for a maximum follow-up of 10 years. Restoration materials included ceramo-metal crowns, full gold crowns, lithium disilicate ceramic, zirconia, polymer infiltrated ceramic networks, and resin composites. Most of the reports assessed the survival rate of the restorations and the clinical features using the United States Public Health Service (USPHS) Evaluation System criteria. Contradictory discoveries were perceived concerning the type of restoration with better clinical performance. Considering the current literature available, there is no evidence in the superiority of any restoration technique to ensure the highest clinical performance for treating tooth wear.

4.
Cells ; 11(15)2022 08 04.
Article in English | MEDLINE | ID: mdl-35954261

ABSTRACT

This study aimed to identify the role of crosslinking agents in the resin-dentin bond strength (BS) when used as modifiers in adhesives or pretreatments to the dentin surface through a systematic review and meta-analysis. This paper was conducted according to the directions of the PRISMA 2020 statement. The research question of this review was: "Would the use of crosslinkers agents improve the BS of resin-based materials to dentin?" The literature search was conducted in the following databases: Embase, PubMed, Scielo, Scopus, and Web of Science. Manuscripts that reported the effect on the BS after the use of crosslinking agents were included. The meta-analyses were performed using Review Manager v5.4.1. The comparisons were performed by comparing the standardized mean difference between the BS values obtained using the crosslinker agent or the control group. The subgroup comparisons were performed based on the adhesive strategy used (total-etch or self-etch). The immediate and long-term data were analyzed separately. A total of 50 articles were included in the qualitative analysis, while 45 articles were considered for the quantitative analysis. The meta-analysis suggested that pretreatment with epigallocatechin-3-gallate (EGCG), carbodiimide, ethylenediaminetetraacetic acid (EDTA), glutaraldehyde, and riboflavin crosslinking agents improved the long-term BS of resin composites to dentin (p ≤ 0.02). On the other hand, the use of proanthocyanidins as a pretreatment improved both the immediate and long-term BS values (p ≤ 0.02). When incorporated within the adhesive formulation, only glutaraldehyde, riboflavin, and EGCG improved the long-term BS to dentin. It could be concluded that the application of different crosslinking agents such as carbodiimide, EDTA, glutaraldehyde, riboflavin, and EGCG improved the long-term BS of adhesive systems to dentin. This effect was observed when these crosslinkers were used as a separate step and when incorporated within the formulation of the adhesive system.


Subject(s)
Dentin-Bonding Agents , Resin Cements , Adhesives/pharmacology , Carbodiimides/pharmacology , Collagen/pharmacology , Dentin , Dentin-Bonding Agents/chemistry , Dentin-Bonding Agents/pharmacology , Edetic Acid/pharmacology , Glutaral/pharmacology , Materials Testing , Resin Cements/chemistry , Resin Cements/pharmacology , Riboflavin
5.
Polymers (Basel) ; 14(6)2022 Mar 11.
Article in English | MEDLINE | ID: mdl-35335459

ABSTRACT

The objective was to evaluate the influence of active bonding applications (ABA) for different time intervals after selective dentin etching (SDE) for 3 s on the microtensile bond strength (µTBS) to dentin of two universal adhesive systems (UAs): one containing 2-hydroxyethyl methacrylate (HEMA) (Scotchbond Universal, SBU), and one that was HEMA-free (Prime&Bond Universal, PBU). Dentin bovine specimens were divided into four groups: self-etch as control (SE), SDE + ABA for 15 s (SDE15), SDE + ABA for 20 s (SDE20), and SDE + ABA for 25 s (SDE25). The µTBS test was performed after a water storage of 24 h and 6 months. Scanning electron microscopy (SEM) was used in order to examine the resin−dentin interface. For the PBU, the µTBS was significantly influenced only by the aging factor (p < 0.026). A statistically significant decrease in the µTBS after 6 months of aging was observed only for the SDE15 group. For SBU, µTBS was significantly influenced by the protocol application and the aging time (p ≤ 0.041). The groups SDE15, SDE20, and SDE25 achieved statistically significant higher values (after 24 h and 6 months). No considerable variances were noticed in the homogeneity and continuity of the hybrid layer (HL) among the groups. In conclusion, SDE and ABA improved the µTBS only of a HEMA-containing universal adhesive.

6.
Polymers (Basel) ; 13(14)2021 Jul 09.
Article in English | MEDLINE | ID: mdl-34301014

ABSTRACT

Various material properties are involved in the success of endodontically treated restorations. At present, restorative composites are commonly employed as core build-up materials. This study aimed to systematically review the literature to assess the effect of using composite core materials on the in vitro fracture of endodontically treated teeth. Two different reviewers screened the literature, up to June 2021, in five distinct electronic databases: PubMed (MedLine), Scopus, Scielo, ISI Web of Science, and EMBASE. Only in vitro studies reporting the effect of the use of composite core materials on the fracture resistance of endodontically treated teeth were included. A meta-analysis was carried out using a software program (Review Manager v5.4.1; The Cochrane Collaboration, Copenhagen, Denmark). The risk of bias in each study was assessed following the parameters of another systematic review. A total of 5016 relevant papers were retrieved from all databases. After assessing the title and abstract, five publications remained for qualitative analysis. From these, only three studies remained for meta-analysis. The fracture strength of endodontically treated teeth where a core build-up composite was used was statistically significantly higher than the control (p = 0.04). Most of the analyses showed a high heterogenicity. The in vitro evidence suggests that the composite core build-up with higher filler content tended to improve the fracture resistance of the endodontically treated teeth, in comparison with conventional composite resins. This research received no external funding. Considering that this systematic review was only carried out on in vitro papers, registration was not performed. Furthermore, there were no identified clinical studies assessing core build-up materials; therefore, more well-designed research on these materials is needed.

SELECTION OF CITATIONS
SEARCH DETAIL
...