Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Am Assoc Lab Anim Sci ; 48(5): 486-91, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19807968

ABSTRACT

This study was conducted to investigate the possible effect of rack type on the blastocyst yield of mouse embryo donors. The first phase of the study consisted of housing some mice (group A) in a ventilated rack and others (group B) in a static rack in the same room for 3 d, followed by euthanasia for blastocyst collection and corticosterone assay. Parametric tests were used to compare groups. The number of blastocysts per donor was lower in group A (5.0 +/- 1.4 blastocysts) than group B (13.1 +/- 3.7 blastocysts). Mean noise was higher in the ventilated rack (80.4 dBC) than in the static rack (69.2 dBC). Serum corticosterone concentrations did not differ between groups. For the second phase of the study, a third group of mice (group C) was housed in a static rack without a ventilated rack in the same room. The noise level for group C was even lower (45.18 +/- 2.91 dBC), and the blastocyst count per donor (16.4 +/- 2.4) was higher than that of group B. The mean noise levels of empty ventilated and static racks differed significantly between groups for 10 different sound frequencies. Plotting mean blastocyst production against mean rack noise revealed a negative linear relationship with good strength of correlation. These results support the earlier observation that decreased blastocyst count occurs following housing of bred C57BL/6 donor mice in ventilated cages.


Subject(s)
Blastocyst/cytology , Housing, Animal , Mice/embryology , Noise , Animals , Corticosterone/blood , Female , Laboratory Animal Science , Mice, Inbred C57BL , Ventilation
2.
J Am Assoc Lab Anim Sci ; 45(4): 24-8, 2006 Jul.
Article in English | MEDLINE | ID: mdl-16884175

ABSTRACT

Timely and accurate detection of murine pathogens is essential in contemporary biomedical research. Cost, accuracy, and reproducibility of test results are frequent concerns when initiating an on-site serology program. This study was conducted to evaluate the advantages of on-site serology performed by enzyme-linked immunosorbent assay (ELISA) versus pathogen surveillance conducted off-site by a commercial vendor. We divided 92 sentinel mouse serum samples and tested them in parallel for a panel of 10 murine pathogens at our institution and by an off-site vendor. On-site testing was performed with commercially available test kits and according to the kit manufacturer's directions, whereas serum samples for off-site testing were prepared according to the vendor's specifications. Results from the 2 testing strategies were compared, and a good beyond- chance level of agreement was demonstrated by means of the kappa test (kappa = 0.86). The turn-around time between sample preparation and results availability for on-site ELISA was 16 h versus 72 h for off-site testing. On-site ELISA demonstrated considerable cost reduction, ranging from 15.10% to 43.33% depending on the number of agents being tested. This study demonstrates the accuracy and time- and cost-effectiveness of on-site ELISA as well as its potentially valuable role in achieving more timely and efficient disease surveillance and control programs in contemporary biomedical research facilities.


Subject(s)
Enzyme-Linked Immunosorbent Assay/veterinary , Mice/microbiology , Rodent Diseases/diagnosis , Serologic Tests/veterinary , Animals , Bacteremia/diagnosis , Bacteremia/veterinary , Enzyme-Linked Immunosorbent Assay/economics , Enzyme-Linked Immunosorbent Assay/standards , Laboratory Animal Science/standards , Population Surveillance , Reproducibility of Results , Serologic Tests/economics , Serologic Tests/standards , Time Factors , Viremia/diagnosis , Viremia/veterinary
3.
Berl Munch Tierarztl Wochenschr ; 115(9-10): 369-80, 2002.
Article in English | MEDLINE | ID: mdl-12357675

ABSTRACT

The efficiency of chemiluminescent immunoassay (CLIA) in detecting Salmonella antibodies in the meat juice of slaughter swine was compared with the indirect ELISA (BgVV method). Based on the screening test results of 987 meat juice samples obtained from different laboratories in Germany, a good level of agreement between the two systems was obtained with a kappa value of 0.824 at 20% cut-off and 0.798 at 40% cut-off. At 20% and 40% cut-off levels, a sensitivity of 96.2% and 97.3%, respectively, and a specificity of 94.6% and 95.1%, respectively, were demonstrated between CLIA and ELISA. The detecting LPS antigen was tested for specificity and a cross-reaction with two E. coli and Yersinia strains was found when tested with ELISA. This reaction was not observed in CLIA, possibly because of the broader measurement spectrum of this test which allows a more distinctive definition of immunologic reactions. The same explanation can be given for the increased number of meat juice samples which were positively detected only in ELISA but not in CLIA. The positively classified samples in screening were further tested for reciprocal titers in both test systems, and a higher correlation between screening and titration results was obtained for CLIA. Towards the end of the study, a preliminary comparison of CLIA with two available commercial ELISA test kits was conducted and the same tendency was observed, namely, wider detection range of CLIA compared to the other tests. Based on the results of this study, CLIA can be used as a reference method in detecting Salmonella antibodies in the meat juice of slaughter pigs.


Subject(s)
Antibodies, Bacterial/analysis , Enzyme-Linked Immunosorbent Assay/veterinary , Immunoassay/veterinary , Meat/microbiology , Salmonella Infections, Animal/diagnosis , Swine Diseases/diagnosis , Animals , Antibodies, Bacterial/blood , Cross Reactions , Enzyme-Linked Immunosorbent Assay/methods , Germany , Immunoassay/methods , Luminescent Measurements , Reference Standards , Sensitivity and Specificity , Swine
SELECTION OF CITATIONS
SEARCH DETAIL
...