Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Optom Vis Sci ; 97(1): 28-35, 2020 01.
Article in English | MEDLINE | ID: mdl-31895275

ABSTRACT

SIGNIFICANCE: The findings of this study indicate that patients could simultaneously be offered the individualized optical correction of wavefront-guided (WFG) lenses and the superior comfort afforded by polymer coatings. This could be helpful to patients with ectasia suffering ocular dryness or dependent on scleral lenses for lengthy periods of wear. PURPOSE: Wavefront-guided scleral lenses target lower- and higher-order aberrations of individual eyes using submicrometer-level contours in the anterior lens surface. Hydrophilic polyethylene glycol (PEG) polymer coatings applied to lens surfaces improve comfort and wettability. This study aimed to quantify aberration changes (e.g., masking) when applying polymer coatings to WFG and conventional scleral lenses. METHODS: Two control lenses (remained uncoated) and 14 experimental lenses (two repeated builds of seven aberration designs: one spherical, two coma, four full WFG [second- to fifth-order aberrations]) were manufactured, and aberrations were measured (mean of three) by two operators before and after coating. Root mean square (RMS) and visual image quality (logVSX) differences were calculated for 6-mm diameters. RESULTS: Median RMS aberration change due to coating was 0.012 µm (range, 0.008 to 0.057 µm). Maximum logVSX change due to coating was 0.073, predicting an approximately one letter change in acuity. Instrument sensitivity was 0.002 µm. Acute instrument and operator variabilities (standard deviations of individual [second- to fifth-order Zernikes] were all <0.027 µm). Longitudinal variability (control lenses) was low: all less than 0.017 µm. Although RMS of differences between repeated builds of all lenses was less than 0.25 D and not statistically significant, relatively, manufacture constituted the major variability, and RMS difference between repeated builds was at least four times greater than the effect of coating (median, 0.167 µm; range, 0.088 to 0.312 µm). CONCLUSIONS: Application of polymer coatings caused measurable changes in aberrations of WFG and conventional scleral lenses; however, these were clinically and statistically insignificant and within variability of repeated lens manufacture. In their current states, WFG lenses and polymer coatings could be used simultaneously.


Subject(s)
Coated Materials, Biocompatible , Contact Lenses , Corneal Wavefront Aberration/physiopathology , Polyethylene Glycols , Sclera , Adult , Female , Humans , Male , Refraction, Ocular/physiology , Visual Acuity/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...