Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 64
Filter
1.
Article in English | MEDLINE | ID: mdl-33575012

ABSTRACT

Background. Local or systemic issues might prevent installing a sufficient number of dental implants for fixed prosthetic rehabilitation. Splinting dental implants and natural teeth in fixed dentures could overcome such limitations. Therefore, this study aimed to evaluate the influence of the number of dental abutments in the biomechanics of tooth‒implant-supported fixed partial dentures (FPDs). The null hypothesis was that increasing the number of abutment teeth would not decrease the stress over the abutments and surrounding bone. Methods. Left mandibular lateral incisor, canine, premolars, and molars were reconstructed through computed tomography and edited using image processing software to represent a cemented fixed metal‒ceramic partial denture. Three models were set to reduce the number of abutment teeth: 1) lateral incisor, canine, and first premolar; 2) canine and first premolar; 3) the first premolar. The second premolar and first molar were set as pontics, and the second molar was set as an implant abutment in all the models. Finite element analyses were performed under physiologic masticatory forces with axial and oblique loading vectors. Results. After simulation of axial loads, the stress peaks on the bone around the implant, the bone around the first premolar, and prosthetic structures did not exhibit significant changes when the number of abutment teeth decreased. However, under oblique loads, decreasing the number of abutment teeth increased stress peaks on the surrounding bone and denture. Conclusion. Increasing the number of dental abutments in tooth‒implant-supported cemented FPD models decreased stresses on its constituents, favoring the prosthetic biomechanics.

2.
J Clin Diagn Res ; 9(5): ZC94-7, 2015 May.
Article in English | MEDLINE | ID: mdl-26155573

ABSTRACT

INTRODUCTION: Reduction of biofilm on dentures is important for maintaining denture wearers' health. OBJECTIVE: The aim of this study was to assess the effectiveness of toothbrush handles individually adapted in reducing of biofilm on dentures. MATERIALS AND METHODS: Study participants were 16 residents of the condo for the elderly, denture wearers, functionally independent and without cognitive impairment. Participants were randomly divided into two groups: Group 1 (adapted toothbrush handles) and Group 2 (conventional toothbrush). Biofilm from the inner surface of the basal area of the denture was observed using 5% erythrosine. Images obtained before starting the use of toothbrushes, after 7 and 21 days were sent for computer analysis. RESULTS: The average amount of biofilm on the first day was considered severe in both groups. At the end of the experiment, the average biofilm coverage in Group 1 was 44.7% (13.1% reduction) and in Group 2 it was 48.6% (4.8% reduction). However, the Friedman analysis of variance test showed that the reduction was statistically significant (p< 0.05) only in Group 1, demonstrating the effectiveness of the adapted brushes. CONCLUSION: The findings of this pilot study indicated that for the reduction of biofilm on dentures the adapted toothbrush handles were superior to the conventional type.

3.
Dent. press implantol ; 7(3): 67-75, July-Sept. 2013. ilus, tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-718873

ABSTRACT

Objetivo: comparar a distribuição de tensões em sistemas de implantes com diferentes tipos de conexões (hexágono externo, hexágono interno e Cone Morse), pelo Método de Elementos Finitos Bidimensional. Métodos: uma força de 100N foi aplicada na cúspide vestibular de um segundo pré-molar inferior, no sentido axial, e, posteriormente, com inclinação de 45o em cada sistema. As análises foram realizadas pelos critérios das tensões de von Mises. Resultados: os resultados apontaram que, em todos os três sistemas, a maior concentração de tensões deu-se na região do pescoço do implante em contato com o osso cortical, com exceção do sistema Cone Morse, onde a tensão se concentrou na porção interna do implante em contato com o pilar. Também foi observado que cargas inclinadas sempre geraram valores superiores aos obtidos com as cargas axiais. Conclusão: pode-se concluir, então, que os parafusos dos pilares são a porção mais frágil dos sistemas. Nos implantes, os sistemas com conexão interna têm distribuição mais uniforme das tensões que o de conexão externa.


Objective: The aim of this study was to compare the stress distribution between implant systems with differenttypes of connections, i.e., external hexagon, internal hexagon and morse taper, by applying the Two-DimensionalFinite Element Method. Methods: A 100-N load was applied to the buccal cusp of an inferior second premolar inthe axial direction and thereafter at an inclination of 45o on each system. Analysis was performed by means ofthe von Mises stresses criteria. Results: The results showed that in, all systems, the highest stress concentrationoccurred in the neck of the implant in contact with the cortical bone, except for the morse taper models, where thestress was concentrated in the inner portion of the implant in contact with the abutment. It also became apparentthat oblique forces resulted in higher stress values than those obtained with axial loads. Conclusion: It could beconcluded that abutment screws are the most fragile portion of the systems. Internal connection implant systemsexhibited a more uniform distribution of stresses than external connection implant systems.


Subject(s)
Dental Implant-Abutment Design , Dental Implantation , Dental Stress Analysis , Finite Element Analysis , Stress, Mechanical
4.
Dent. press implantol ; 7(1): 95-104, Jan.-Mar. 2013. ilus
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-704443

ABSTRACT

Introdução: o conceito all-on-four preconiza a inclinação dos implantes distais com o objetivo de reduzir o cantiléver distal. Objetivo: avaliar a biomecânica através da análise com elementos finitos tridimensionais, a inclinação dos implantes distais e a utilização de componentes protéticos angulados e retos no tratamento de mandíbulas edêntulas. Métodos: quatro modelos tridimensionais de mandíbula foram criados simulando tecido ósseo cortical e medular. Foram instalados nos modelos quatro implantes paralelos com componentes protéticos retos, dois implantes retos com os dois implantes distais inclinados em 17 ou 30° com componentes protéticos retos ou angulados. Todos os modelos foram carregados axialmente ou obliquamente bilateral, ou unilateralmente em toda a extensão da prótese. Resultados: o uso de implantes retos e os componentes angulados apresentaram maiores concentrações de tensões. A inclinação distal dos implantes favoreceu a distribuição de tensões. Conclusão: o conceito all-on-four com o uso de componentes protéticos retos favorece a biomecânica de reabilitações totais implantossuportadas.


Subject(s)
Dental Implants , Dental Prosthesis, Implant-Supported , Finite Element Analysis , Jaw, Edentulous, Partially , Biomechanical Phenomena , Imaging, Three-Dimensional , Mandible
5.
ImplantNews ; 10(5): 587-592, 2013. ilus
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-699622

ABSTRACT

A descrição de técnicas de instalação de implantes e carga imediata tem lugar de destaque na literatura científica. A aplicação de carga imediata segue um protocolo rigoroso de trabalho e uma indicação precisa. Este trabalho teve como objetivo demonstrar um caso clínico onde foi utilizada a carga imediata para tratamento da agenesia do elemento 12 utilizando implante de plataforma estreita e técnica transgengival, sem abertura de retalho.


Implant placement techniques such as immediate loading protocols have received considerable attention on the scientific literature. However, immediate loading follows a strict protocol and precise indications. This paper presents a case report where agenesis at the maxillary right lateral incisor (12) was managed by using a narrow diameter implant with a flapless technique approach.


Subject(s)
Humans , Young Adult , Anodontia , Immediate Dental Implant Loading
6.
RGO (Porto Alegre) ; 60(3): 315-320, jul.-set. 2012. tab
Article in English | LILACS, BBO - Dentistry | ID: biblio-874688

ABSTRACT

Objective: This in vitro study evaluated the disinfection action of peracetic acid on chemically activated acrylic resin. Methods: Sixty chemically activated acrylic resin specimens were contaminated with Candida albicans (30) and Bacillus subtilis (30) for 15 minutes. Next, specimens were divided into Control Group (Group 0) and Test Group (T) for each studied microorganism. The antimicrobial effect of Proxitane® Alfa (Thech Desinfecção, São Paulo, Brazil), containing 0.25% and 0.025% concentrations of peracetic acid was verified after 1, 3, 5 and 10 minutes of exposure. The specimens were transferred to saline solution for 5 minutes, homogenized and aliquots of 100µL were plated on BHI and Sabouraud Dextrose agar. After incubation at 37ºC/24h, the number of CFU/mL recovered from each specimen was obtained. Results: The 0.025 % peracetic acid was effective against B. subtilis only after 10 minutes and against C. albicans after 3 minutes of exposure. At 0.25% concentration, the solution showed fungicidal and bactericidal efficacy after 1 minute of exposure. Conclusion: The 0.25% peracetic acid was shown to be efficient for disinfection of chemically activated acrylic resins.


Objetivo: Avaliar in vitro a ação desinfetante do ácido peracético sobre resina acrílica quimicamente ativada. Métodos: Sessenta corpos de prova em resina acrílica quimicamente ativada foram contaminados em suspensão de Candida albicans (n=30) e Bacillus subtilis (n=30) por 15 minutos. A seguir, os corpos de prova foram divididos em grupo Controle (Grupo 0), com 6 espécimes e Grupo teste composto por 24 espécimes para cada microrganismo estudado. Proxitane® Alfa (Thech Desinfecção, São Paulo, Brasil) ácido peracético foi testado nas concentrações de 0,25% e 0.025%, após 1, 3, 5 e 10 minutos de exposição. Após, cada corpo de prova foi transferido para solução fisiológica por 5 minutos, homogeneizados e alíquotas de 100 µL foram semeadas em duplicata, em BHI e Sabouraud Dextrose ágar. Após incubação a 37ºC / 24 horas, determinou-se o número de UFC/ml recuperado de cada espécime.Resultados: Na concentração de 0,025%, o ácido peracético mostrou efeito frente a Bacillus subtilis apenas após 10 minutos e para Candida albicans, após 3 minutos. Na concentração de 0,25%, a solução mostrou efeito fungicida e bactericida após apenas 1 minuto de exposição.Conclusão: O ácido peracético a 0,25% demonstrou-se eficaz na desinfecção de resina acrílica quimicamente ativada.


Subject(s)
Disinfection , Denture, Complete , Acrylic Resins , Peracetic Acid , Dental Prosthesis
7.
ISRN Dent ; 2012: 730674, 2012.
Article in English | MEDLINE | ID: mdl-23320186

ABSTRACT

Aim. The aim of the present study was to compare the dimensional accuracy of stone casts obtained with vinyl polysiloxane molds through the double-impression technique with three pours into the same mold. Methods. A stainless steel master model was constructed simulating a three-unit fixed prosthesis. Twelve impressions were taken of this master model with addition silicone, using the double-impression technique. Three pours of type IV gypsum were then made into each mold, thus producing 36 casts. The pours were made 1 hour, 6 hours and 24 hours after the impression procedure. Next, intra- and interabutment measurements were made in a coordinate measuring machine. Results. Comparative analysis of the dimensional accuracy of stone casts resulting from multiple pours was not statistically significant in pours first and second (P > 0.05). These values, however, were statistically significant at third pour in the height in abutment 1 and upper distance interabutment. Conclusion. The wait time (1 hour, and 6 hours) observed before pouring the stone into the same molds did not cause significant dimensional accuracy of the casts.

8.
RGO (Porto Alegre) ; 59(supl.1): 81-88, Abr.-Jun. 2011. graf
Article in Portuguese | LILACS | ID: lil-766072

ABSTRACT

Este trabalho mostra uma técnica de preparo dental denominada de "Técnica de Referência para Preparo Dental Inoue & Zanetti". Esta técnica foi inspirada no desgaste através da confecção de sulcos de orientação e ao contrário da maioria das técnicas de preparos que utilizam sulcos verticais, nesta técnica os sulcos são horizontais. Foi idealizado um kit de pontas diamantadas especiais de uso sequencial (kit Inoue/Zanetti/Feltrin - kg - Sorensen- ref. 6727) e foram desenvolvidas pontas específicas para espessura de desgaste desejada em função do tipo de coroa selecionada. Os instrumentos cortantes rotatórios foram idealizados para que o desgaste seja mínimo sem prejudicar a estética na região cervical. Consequentemente terá um menor dano ao periodonto de proteção facilitando a moldagem e a cinta metálica das coroas metalocerâmicas poderá ser menor, facilitando à estética. Os tipos de terminações marginais também são analisados, conferindo ao degrau inclinado 1350 a terminação ideal para coroas metalocerâmicas em dentes anteriores.


The paper presents a tooth preparation technique called "Inoue & Zanetti Dental Preparation Technique". This technique was inspired in the confection of orientation sulci. A special diamond burs points was created (The Inoue/Zanetti/Feltrin diamond points kit - KG - Sorensen- ref. 6727) specific for the obtainment of the desired amount of wear, for each kind of tooth preparation. Cutting rotatory instruments were developed in order to demand less dental waste without damage in the periodontal tissues. The kit enables the operator to confect aesthetic restorations with the amount of wear and marginal endings of 1350, specific for metalloceramic crowns in anterior teeth..

9.
Photomed Laser Surg ; 28(2): 273-80, 2010 Apr.
Article in English | MEDLINE | ID: mdl-19811080

ABSTRACT

OBJECTIVE: To evaluate the potential of 980-nm gallium aluminum arsenide (GaAlAs) and 1064-nm neodymium-doped yttrium aluminum garnet (Nd:YAG) lasers to reduce bacteria after irradiation of implant surfaces contaminated with Enterococcus faecalis and Porphyromonas gingivalis and on irradiated implant surface morphology. BACKGROUND: Despite the frequency of implant success, some implant loss is related to peri-implantitis because of difficulty in eliminating the biofilm. METHODS: Implants (3.75 x 13 mm) with machined surfaces, surfaces sand blasted with titanium oxide (TiO(2)), and sand-blasted and acid-etched surfaces were exposed to P. gingivalis and E. faecalis cultures and irradiated with 980-nm GaAlAs or 1064-nm Nd:YAG lasers. After laser treatments, the number of remaining colony-forming units and implant surface morphology were analyzed using scanning electron microscopy (SEM). RESULTS: The Nd:YAG laser was able to promote a total contamination reduction on all implants irradiated. The results with the GaAlAs laser showed 100% bacteria reduction on the implants irradiated with 3 W. Irradiation with 2.5 W and 3 W achieved 100% of bacteria reduction on P. gingivalis-contaminated implants. Decontamination was not complete for the sand-blasted TiO(2) (78.6%) and acid-etched surfaces (49.4%) contaminated with E. faecalis and irradiated with 2.5 W. SEM showed no implant surface changes. CONCLUSION: The wavelengths used in this research provided bacteria reduction without damaging implant surfaces. New clinical research should be encouraged for the use of this technology in the treatment of peri-implantitis.


Subject(s)
Dental Implants/microbiology , Disinfection/methods , Lasers, Semiconductor , Lasers, Solid-State , Biofilms/radiation effects , Enterococcus faecalis/radiation effects , Porphyromonas gingivalis/radiation effects
10.
ImplantNews ; 6(4): 373-379, 2009. ilus, tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-544176

ABSTRACT

O presente estudo avaliou quatro casos clínicos onde um xenoenxerto bovino composto osteossubstituto foi usado para regeneração da perda óssea. Três casos de alvéolos dentais pós-extração atraumática e um caso de procedimento de elevação de seio maxilar usando técnica de reposição lateral, objetivando a colocação de implante, foram tratados com xenoenxerto composto. Quatro a oito meses, previamente à colocação de implante, as áreas enxertadas foram reoperadas e biópsias ósseas removidas por brocas trefinas. Após seis meses da colocação dos implantes, os elementos protéticos estiveram em função e mostrando sucesso clínico. A análise histológica das biópsias mostrou ausência de infiltrado inflamatório e presença de tecido ósseo neoformado fora e dentro de poros e fendas do biomaterial. O xenoenxerto foi biocompatível e permitiu a aposição de novo osso, indicando seu uso antes da colocação de implantes osseointegrados.


The present study evaluated four clinical cases where a xenograft bovine compound bone substitute was used for regeneration of bone loss. Three cases of dental sockets after non-traumatic tooth extractions and one case of maxillary sinus augmentation procedure using the lateral approach technique, aiming further implant placement, were treated with xenograft compound. Four to eight months before implant placement, the grafted areas were reopened and bone biopsies carried out by trephine burs. Six months after implant placement, the prosthetic elements were in function showing clinical success. Histological analysis of biopsies showed absence of inflammatory infiltrate and the presence of new bone tissue over and inside pores and grooves of the biomaterial as well. The xenograft was biocompatible and allowed the apposition of new bone, supporting its use before dental implant placement.


Subject(s)
Humans , Biocompatible Materials , Bone Substitutes , Bone Transplantation , Transplantation, Heterologous
11.
RGO (Porto Alegre) ; 57(4): 395-399, out.-dez. 2009. ilus, tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: biblio-873854

ABSTRACT

Objetivos: Avaliar o potencial de redução bacteriana do laser de diodo 980nm em três diferentes tipos de superfícies de implantes dentários contaminados com Enterococcus faecalis e Porphyromonas gingivalis, bem como estudar por microscopia eletrônica de varredura possíveis alterações na superfície dos implantes irradiados. Métodos: Foram utilizados 72 implantes com diferentes tratamentos de superfície (usinado; jateados com óxido de titânio; e ataque ácido). Os implantes foram contaminados com duas cepas bacterianas, Enterococcus faecalis e Porphyromonas gingivalis, e, posteriormente, irradiados pelo laser de diodo 980nm, nas potências de 2,5 e 3,0W. Após os tratamentos a laser, o número de unidades formadoras de colônias foi analisado e o grupo controle, não contaminado, mas irradiado pelo laser, foi submetido à microscopia eletrônica de varredura, para a avaliação de possíveis alterações na superfície dos implantes. Resultados: Os resultados mostraram que houve 100% de redução bacteriana nos implantes irradiados com 3,0W, e redução bacteriana total dos implantes contaminados com Porphyromonas gingivalis, mesmo quando irradiados com 2,5W. A redução bacteriana só não foi total para os implantes contaminados com Enterococcus faecalis irradiados com potência de 2,5W e com superfície jateada com TiO2 (78,6%), e com superfície com ataque ácido (49,4%). A análise em microscopia eletrônica de varredura mostrou que, com os parâmetros energéticos utilizados nesta pesquisa, não houve alteração da superfície dos implantes. Conclusão: O laser de diodo 980nm foi efetivo na descontaminação do Enterococcus faecalis e Porphyromonas gingivalis sem promover a alteração na superfície dos implantes.


Objective: To evaluate the potential of 980nm diode laser to reduce bacteria after irradiation of three different dental implant surfaces contaminated with Enterococcus faecalis and Porphyromonas gingivalis, as well as the possible changes in the irradiated implant surfaces. Methods: Seventy two implants with machined surfaces, airborne particle abraded with titanium oxide and acid-etched surfaces were exposed to Enterococcus faecalis and Porphyromonas gingivalis cultures and irradiated with 980nm diode laser with power of 2.5 and 3,0W. After laser treatments, the number of remaining colony-forming units was studied and implant surface morphology was analyzed by scanning electron microscopy. Results: The results showed 100% reduction of the bacteria on the implants irradiated with 3.0W. Moreover, 100% reduction of bacteria was also achieved on the implant surfaces contaminated with Porphyromonas gingivalis when irradiated with 2.5W and 3.0W. Bacteria reduction was not complete for the implants contaminated with Enterococcus faecalis, irradiated with 2.5W and surfaces treated with TiO2 airborne particle abrasion (78.6%) and acid etching (49.4%).The scanning electron microscopy analysis showed that at the power settings used, no implant surface changes were found. Conclusion: The 980nm diode laser was effective in decontaminating the Enterococcus faecalis and Porphyromonas gingivalis without promoting surface alteration in the implants.


Subject(s)
Disinfection , Dental Implants , Lasers, Semiconductor , Enterococcus faecalis , In Vitro Techniques , Porphyromonas gingivalis
12.
Rev. bras. implantodontia ; 13(2): 16-20, abr.-jun. 2007. ilus
Article in Portuguese | BBO - Dentistry | ID: biblio-857124

ABSTRACT

Muitos pacientes edentulos buscam reabilitação da maxila por meio de próteses fixas implanto suportadas, tendo como expectativa final a obtenção de um tratamento com resultado estético e funcional semelhante a dentição natural. Infelizmente, a reabsorção óssea ocorre após a perda da dentição natural, que é um processo contínuo e progressivo comprometendo muitas vezes a reabilitação total por meio de próteses fixas implanto suportadas pois há a perda de suporte labial e ausência de papila interdental. Sendo assim, o presente trabalho relata um caso com controle de 5 anos, sugerindo o tratamento protético reabilitador da maxila por meio de prótese fixa implanto suportada utilizando como alternativa a epítese gengival ou gengiva artificial removível solucionando problemas advindos da reabsorção óssea, otimizando a estética e fonética


Most of edentulous patients seeking rehabilitation of their upper jaw through fixed implant support prostheses, expect as a final result a treatment with aesthetic and functional results similar to natural teeth. Unfortunately, the bone resorption occurs after the natural dention loss, as a progressive and continuous process, compromising most of the times, the total rehabilitation through fixed implant supported prostheses, due to lack of lip support and absence of interdentual papilla. Based on that, the article presents a clinical report controlled for 5 years suggesting a prosthetic rehabilitation treatment of an edentulous upper jaw patient through fixed implant supported prostheses using gingival epithesis or removable artificial gum as an alternative for solving problems caused by bone resorption and optimizing the aesthetic and fonetic


Subject(s)
Humans , Female , Middle Aged , Denture, Complete , Gingiva , Mouth Rehabilitation , Bone Resorption , Bone Transplantation , Esthetics, Dental
13.
RGO (Porto Alegre) ; 54(2): 185-190, abr.-jun. 2006. ilus
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-457171

ABSTRACT

As cerâmicas utilizadas em Odontologia são caracterizadas pela natureza refratária, dureza, biocompatibilidade e transmissão de luz. Com a evolução das cerâmicas, tem-se obtido restaurações com aspecto cada vez mais próximas a realidade, por permitirem uma transmissão de luz difusa, uniforme capaz de reproduzir a profundidade de translucidez, cor e textura dos dentes naturais. Contudo, as restaurações de cerâmica pura apresentam como desvantagem a susceptibilidade à fratura, verificada clinicamente e resultante de vários fatores, porém, nem sempre observados nas pesquisas realizadas por meio de testes "in vitro" por não submeterem os materiais às mesmas condições que comportam "in vivo", e assim, resultando muitas vezes, em dados nem sempre reais. Portanto, por meio de um levantamento bibliográfico sobre os fatores envolvidos nos testes de resistência à fratura dos sistemas cerâmicos reforçados por leucita, disilicato de lítio e alumina, verificou-se que, estes testes, podem ser influenciados por uma variedade de fatores como: número de amostras utilizadas na pesquisa; período de avaliação; região a ser restaurada; tipo de material cerâmico; tipo e espessura de cimento utilizado; condicionamento da superfície da cerâmica, glaze e polimento da superfície da cerâmica, ajuste oclusal após a cimentação, dentre outros. Sendo assim, verificou-se que a existência de um protocolo para os testes de resistência à fratura de materiais cerâmicos, é de suma importância para que se possa obter resultados confiáveis e capazes de retratar a realidade clínica.


Subject(s)
Ceramics , Dental Porcelain , Tensile Strength
14.
ImplantNews ; 3(3): 281-285, maio-jun. 2006. ilus
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-457401

ABSTRACT

A descrição de técnicas de instalação de implantes e carga imediata tem lugar de destaque na literatura científica. A aplicação de carga imediata segue um protocolo rigoroso de trabalho e uma indicação precisa. Este trabalho tem como objetivo demonstrar um caso clínico onde foi utilizada a carga imediata para tratamento da agenesia do elemento 12 utilizando implante de plataforma estreita e técnica transgengival, sem abertura de retalho.


Subject(s)
Humans , Female , Adult , Anodontia , Dental Implantation, Endosseous , Dental Implants, Single-Tooth , Esthetics, Dental
15.
Rev. bras. implantodontia ; 12(2): 5-7, abr.-jun. 2006. ilus
Article in Portuguese | BBO - Dentistry | ID: biblio-857103

ABSTRACT

Este trabalho clínico tem como objetivo apresentar a reabilitação protética de um paciente parcialmente edentado por meio da confecção de uma overdenture inferior, retida por um novo sistema de barra clip (Dyna® Instant Adjustable Bar) e uma prótese total superior. O planejamento do caso contou com a exodontia de elementos dentários comprometidos periodontalmente, e a posterior temporização com uma prótese total imediata inferior retida por implantes temporários com o objetivo do tratamento de fibromucosa. Posteriormente a este procedimento, frente à uma fibromucosa saudável e regularizada, foram colocados 2 implantes osseointegrados (Conexão Porous) na região de 32 e 42, que no mesmo procedimento cirúrgico receberam um sistema de barra clíp ajustável pré fabricado que permitiu a carga e união entre os implantes. Após 2 meses foi instalado um clip na prótese total inferior, e ativado o sistema de retenção


This clinical case aims to present a prosthetic rehabilitation of a partial edentulus patient by using a lower overdenture, retained by a new bar system (Dyna® Instant Adjustable bar) and an upper full denture. The initial planning was the remaining teeth extractions, and the placement of an overdenture retained by two temporary implants and a ball system for providing the mucosa treatment. After that, with a healthy and regular mucosa, two osteointegrated implants (Conexão-Porous) were placed in the region 32 and 42, which received in the same surgical procedure a bar system providing their connection in a proper gingival length. A golden clip was installed in the lower overdenture two months after the surgical procedure, activating the retention system


Subject(s)
Humans , Female , Young Adult , Denture, Complete , Surgery, Oral , Mouth Rehabilitation
16.
PCL, Rev. Íbero Am. Prótese Clín. Lab. ; 8(40): 136-149, abr.-jun.2006. ilus, tab, graf, CD-ROM
Article in Portuguese | BBO - Dentistry | ID: biblio-853157

ABSTRACT

Este estudo avaliou a habilidade de duas técnicas, uma convencional e uma de transferência direta do molde, para a montagem do modelo de gesso da maxila no articulador. Um único paciente do sexo feminino, 39 anos, portador de arcada superior de Classe I de Kennedy (desdentado posterior bilateral) foi usado para essa investigação. Foram obtidos 20 modelos de gesso em cada técnica, totalizando 40 montagens nos articuladores. Com o modelo superior montado, cada articulador foi fotografado do mesmo lado direito da radiografia em norma lateral da paciente, obtida com o arco facial montado em sua face. As medidas analisadas nos traçados realizados sobre as fotografias e na radiografia foram obtidas calculando-se o ângulo entre a interseção do plano oclusal da maxila e o plano de referência horizontal ou plano de Frankfurt (12,02°*), representado pelo arco facial na radiografia da paciente, comparando-o com o ângulo entre o plano oclusal do modelo de gesso e o ramo superior do articulador na técnica convencional (8,65°*) e na técnica de transferência direta (11,83°*), por meio do software UTHSCSA Image Tool. Os dados foram submetidos à análise estatística. Os resultados deste estudo demonstraram uma capacidade maior de reprodução daquele ângulo quando uma técnica de transferência direta do molde é usada. Da mesma maneira, foi verificado uma distorção significante na reprodutibilidade dos modelos montados pela técnica convencional. * média geral dos valores médios das 20 montagens em cada técnica


Subject(s)
Humans , Female , Adult , Dental Articulators , Dental Impression Technique , Models, Dental , Calcium Sulfate , Casts, Surgical , Models, Anatomic
17.
Rev. odontol. Univ. Cid. Sao Paulo ; 18(1): 87-92, jan.-abr. 2006.
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-556771

ABSTRACT

Pensando nas interfaces que a psicanálise tem com inúmeras áreas do conhecimento, este trabalho aponta para uma abordagem integradora entre odontologia e psicanálise. Este artigo procura relatar entrevistas com pacientes desdentados totais, suas histórias de vida, emoções e sentimentos que tiveram na relação com a dentista antes e depois da colocação das suas próteses totais. A discussão foi feita à luz da psicanálise e é um convite para os profissionais permitirem-se escutar os seus pacientes. Aborda uma nova forma de enfrentamento da realidade de hoje, de articular e integrar diferentes tipos de conhecimento.


Considering the interfaces that psychoanalysis has with countless other fields, this study proposes an integration of approaches in dentistry with psychoanalysis. The objective of this study is to relate interviews conducted with totally edentulous patients, regarding their life stories, emotions and feelings experienced in the relationship with their dentist before and after the placement of their total prostheses. The discussion was conducted in light of psychoanalysis and it is an invitation for professionals to listen to their patients. It addresses a new way of connecting and integrating knowledge from different fields to face today’s situations.


Subject(s)
Humans , Male , Female , Adult , Aged , Geriatric Dentistry , Practice, Psychological , Denture, Complete , Psychoanalysis , Professional-Patient Relations
18.
ImplantNews ; 2(5): 491-497, set.-out. 2005. ilus
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-455396

ABSTRACT

O objetivo deste trabalho é apresentar um caso clínico de reparação tecidual de um elemento dental fraturado. A paciente OKR, sexo feminino, 65 anos, com queixa de processo doloroso relacionado ao elemento 23, com fratura radicular e fístula gengival.O elemento dental foi extraído, seguido por uma descontaminação do tecido ósseo e gengival por meio do laser de Nd:YAG,1064 nm com 1 watt de potência. O leito irradiado recebeu um substituto ósseo (Gen Tech®) recoberto por uma membrana reabsorvível (Gen Derm®). Seis meses após a enxertia, o local recebeu três implantes osseointegrados Conexão-Porous. A biópsia obtida antes da colocação dos implantes da área tratada com o substituto ósseo foi submetida à análise histológica que apresentou um tecido ósseo neoformado com presença de células osteogênicas com deposição de tecido ósseo nos poros e fendas do material. Os resultados obtidos permitem concluir que a descontaminação com laser de Nd:YAG possibilitou a enxertia direta com Gen-Tech® que se mostrou biocompatível, promovendo a reparação do alvéolo e a futura colocação de implantes osseointegrados


Subject(s)
Humans , Female , Middle Aged , Bone Transplantation , Lasers , Tooth Fractures , Dental Implantation, Endosseous
19.
RPG rev. pos-grad ; 12(3): 293-300, jul.-set. 2005. ilus, tab
Article in English | LILACS, BBO - Dentistry | ID: lil-556092

ABSTRACT

This study compared the suitability of different connections between abutment tooth and prosthesis and between prosthesis and implant in a model of a mandibular distal implant-supported RPD. Finite Element Analysis (FEA) was used, with the application of strictly vertical loads, varying the type of connection, rigid or hinged, between the RPD and the abutment tooth, and between the RPD and the implant. In the model, the load on the abutment tooth rose from 15.2 N to 33.2 N when the link between the abutment tooth and the RPD changed from hinged to right and the link between implant and RPD changed from rigid to hinged. The load on the implant decrease from 84.8 N to 66.7 N when the link between the abutment tooth and the RPD changed from hinged to rigid and the link between the implant and the RPD changed from rigid to hinged. The bending moment on the implant decrease from 0.18 Nm to zero when the connection between the implant and the RPD changed from rigid to hinged. Maximum deflection of the RPD varied from -1.95 micrometer to -5.09 micrometer as the links changed from right to hinged. A rigid connection between the abutment tooth and the RPD transmitted higher loads to the abutment tooth and decreased loading on the alveolar ridge mucosa and on the implant when compared to a hinged connection, and a hinged connection between the implant and the RPD decreased the bending moment transmitted to the implant and increased loads on the alveolar ridge mucosa and on the abutment tooth. We concluded that a hinged connection is recommended between the prosthesis and the implant to preserve the implant and prevent bone resorption.


Subject(s)
Finite Element Analysis , Dental Prosthesis, Implant-Supported , Denture, Partial, Removable , Dental Abutments , Dental Implants/methods
20.
RGO (Porto Alegre) ; 53(1): 12-16, jan.-mar. 2005. ilus, tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-412559

ABSTRACT

Este trabalho avaliou comparativamente, em laboratório a fidelidade dimensional de quatro materiais de moldagem usados nas moldagens finais em prótese total, um hidrocolóide irreversível (Hidrogum), um poliéter (Impregum) e dois silicones de adição (Honigum e Extrude), bem como a técnica de dupla moldagem, com ou sem alívio, usando o material Extrude de consistências média e leve. Concluiu-se que, com exceção do material Extrude em moldagem simples, os silicones e o poliéter tiveram desempenho semelhante, e que o hidrocolóide irreversível evidenciou os piores resultados. Outra conclusão foi que as duas técnicas de dupla moldagem usando materiais de consistências diferentes mostraram resultados semelhantes ao Honigum e Impregum, sendo mais precisas que estes na reprodução da altura, medida relacionada com a moldagem da zona de postdamming no paciente edêntulo


Subject(s)
Humans , Dental Impression Materials , Dental Impression Technique , Denture, Complete
SELECTION OF CITATIONS
SEARCH DETAIL
...