1.
Proc Inst Mech Eng H ; 224(7): 823-30, 2010.
Article in English | MEDLINE | ID: mdl-20839650

ABSTRACT

Modification of knee joint wear simulation methods has included 'anatomic attachment' of unicondylar knee replacements (UKR) onto synthetic femurs with material properties and morphology similar to human femurs. The present study assesses the effect of such modification by comparing the damage patterns on UKR polyethylene inserts after in vitro simulation using standard and modified simulation methods with those on inserts retrieved after in vivo function. Three groups of UKR inserts were evaluated after retrieval (Explant Group, n = 17) or after knee joint wear simulation with the components attached to standard metal blocks (Standard Group, n = 6) or synthetic femurs (Anatomic Group, n = 6). All UKR had similar non-conforming articular surfaces. Articular damage patterns (mode, frequency, and area) were quantified using digital image photogrammetry. Although some common damage modes were noted, knee joint wear simulation with standard or 'anatomic' attachment did not generate damage pattern sizes similar to the explanted UKR. A focal damage pattern consistent with contact between the metal femoral articular surface and the polyethylene inserts was evident on all inserts, but only the Explant Group had evidence of dispersed damage dominated by abrasive modes. Synthetic femurs added complexity to the wear simulation without generating wear patterns substantially more similar to those observed on retrieved inserts.


Subject(s)
Knee Prosthesis , Biomechanical Phenomena , Computer Simulation , Equipment Failure Analysis , Humans , In Vitro Techniques , Materials Testing , Models, Biological , Polyethylene , Prosthesis Design
2.
Phys Med Biol ; 53(19): 5357-69, 2008 Oct 07.
Article in English | MEDLINE | ID: mdl-18757998

ABSTRACT

Knee osteoarthritis is a complex clinical scenario where many biological and mechanical factors influence the severity of articular degenerative changes. Minimally invasive knee prosthetic surgery, with only a compartment replacement (unicompartmental knee replacement), might be a good compromise between osteotomy and total knee prosthesis. The focus of this study was to develop and validate a protocol to assess the fixation method of the femoral components in mechanical simulation, for pre-clinical validation; the wear behaviour of two different fixation frames was quantified and compared. In particular, two different wear tests were conducted using the same knee simulator, the same load profiles and the same kinematics; two different fixation methods were applied to the femoral sleds (synthetic femur and metal block). Surface characterization on both articulating bearings was performed by a roughness measuring machine and coordinate measuring machine. The wear produced by the tibial inserts using the synthetic femur was considerably higher than the wear registered by the metal-block holder. Roughness measurements on femoral sleds showed a limited number of scratches with high R(t) values for the metal-block set-up; the damaged surface broadened in the case of femoral condyles and tibial inserts mounted on composite bone, but lower R(t) and linear penetration values were measured. The two holding frames showed different wear activities as a consequence of dissimilar dynamic performance. Further observations should be made in vivo to prove the actual importance of synthetic bone simulations and specific material behaviour.


Subject(s)
Knee Prosthesis , Menisci, Tibial/surgery , Orthopedic Fixation Devices , Biomechanical Phenomena , Feasibility Studies , Mechanics , Metals , Reproducibility of Results , Surface Properties
3.
Proc Inst Mech Eng H ; 222(5): 617-28, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18756681

ABSTRACT

The wear of metal-on-metal bearings is affected by various design parameters, such as the clearance or surface roughness. It would be very useful to have a significant indicator of wear according to these design parameters, such as the lambda ratio. Three different batches of cast high- and low-carbon cobalt-chromium hip implants (28 mm, 32 mm, and 36 mm diameters) were tested in a hip joint simulator for 2 x 10(6) cycles. Bovine calf serum was used as lubricant, and the samples were weighed at regular intervals during the test. The predictive role of the lambda ratio on the wear behaviour was investigated. Three different configurations were tested to explore the wear rate for a broad range of lambda ratios. The results of these studies clearly showed that the femoral heads of 36 mm diameter had the best wear behaviour with respect to the other two smaller configurations tested. From a predictive point of view, the lambda ratios associated with the configurations tested could clearly indicate that the femoral heads of 36 mm diameter worked in the mixed-lubrication regime (lambda > 1); all the smallest configurations (28mm size) had lambda < 1, thus showing their aptitude to work in the boundary lubrication regime, with substantially higher volume depletion due to wear. The lambda values associated with the 32 mm size varied in a range around 1 (0.95 < lambda < 1.16), suggesting the possibility of operating in the mixed-lubrication regime.


Subject(s)
Equipment Failure Analysis/methods , Hip Prosthesis , Materials Testing/methods , Metals/chemistry , Models, Theoretical , Biocompatible Materials/chemistry , Computer Simulation , Humans , Reproducibility of Results , Sensitivity and Specificity , Surface Properties
4.
Med Eng Phys ; 30(10): 1305-17, 2008 Dec.
Article in English | MEDLINE | ID: mdl-18774742

ABSTRACT

Interest in the rheology and effects of interacting surfaces is as ancient as man. This subject can be represented by a recently coined word: tribology. This term is derived from the Greek word "tribos" and means the "science of rubbing". Friction, lubrication, and wear mechanism in the common English language means the precise field of interest of tribology. Wear of total hip prosthesis is a significant clinical problem that involves, nowadays, a too high a number of patients. In order to acquire further knowledge on the tribological phenomena that involve hip prosthesis wear tests are conducted on employed materials to extend lifetime of orthopaedic implants. The most basic type of test device is the material wear machine, however, a more advanced one may more accurately reproduce some of the in vivo conditions. Typically, these apparatus are called simulators, and, while there is no absolute definition of a joint simulator, its description as a mechanical rig used to test a joint replacement, under conditions approximating those occurring in the human body, is acceptable. Simulator tests, moreover, can be used to conduct accelerated protocols that replicate/simulate particularly extreme conditions, thus establishing the limits of performance for the material. Simulators vary in their level of sophistication and the international literature reveals many interpretations of the design of machines used for joint replacement testing. This paper aims to review the current state of the art of the hip joint simulators worldwide. This is specified through a schematic overview by describing, in particular, constructive solutions adopted to reproduce in vivo conditions. An exhaustive commentary on the evolution and actually existing simulation standards is proposed by the authors. The need of a shared protocol among research laboratories all over the world could lead to a consensus conference.


Subject(s)
Biomimetic Materials , Equipment Failure Analysis/instrumentation , Hip Joint/physiopathology , Hip Joint/surgery , Hip Prosthesis , Physical Stimulation/instrumentation , Equipment Design , Equipment Failure Analysis/methods , Humans , Physical Stimulation/methods , Rheology/instrumentation , Rheology/methods
5.