Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
Cancer Invest ; 32(5): 159-67, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24605900

ABSTRACT

A dosimetric comparison was made of Helical Tomotherapy (HT) and Rapid'Arc(®) (RA) in 115 patients with head and neck carcinoma included in a prospective and multicentric study. HT and RA provided highly conformal plans that easily complied with dose volume constraints for organs at risk. HT reduced high doses to the planning target volumes (PTVs) compared to RA and provided a more homogeneous dose distribution but with an increased Non Tumoral Integral Dose (NTID) than RA. However, the clinical consequences of these dosimetric advantages and disadvantages need further investigation.


Subject(s)
Head and Neck Neoplasms/radiotherapy , Radiometry/methods , Radiotherapy, Intensity-Modulated/methods , Adult , Aged , Female , Humans , Male , Middle Aged , Neoplasm Staging , Prospective Studies , Radiometry/adverse effects , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated/adverse effects , Young Adult
3.
Radiother Oncol ; 94(3): 300-6, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20171752

ABSTRACT

BACKGROUND AND PURPOSE: To evaluate the dosimetry of helical tomotherapy (HT) and three-dimensional conformal radiotherapy (3D-CRT) in breast cancer patients undergoing whole breast radiation with simultaneous integrated boost (SIB) of the tumor bed. MATERIAL AND METHODS: Thirteen patients with breast cancer treated by lumpectomy and requiring whole breast radiotherapy with tumor bed boost were planned using both HT and 3D-CRT using the field-in-field technique. The whole breast and tumor bed were prescribed 50.68 Gy and 64.4 Gy, respectively, in 28 fractions. Dosimetries for both techniques were compared. RESULTS: Coverage of the whole breast was adequate with both techniques (V(95%)=96.22% vs. 96.25%, with HT and 3D-CRT, respectively; p=0.64). Adequate tumor bed coverage was also achieved, although it was significantly lower with HT (V(95%)=97.18% vs. 99.72%; p<0.001). Overdose of the breast volume outside the tumor bed was significantly lower with HT (V(54.23 Gy)=12.47% vs. 30.83%; p<0.001). Ipsilateral lung V(20 Gy) (6.34% vs. 10.17%; p<0.001), V(5 Gy) (16.54% vs. 18.53%; p<0.05) and mean dose (4.05 Gy vs. 6.36 Gy; p<0.001) were significantly lower with HT. In patients with left-sided tumors, heart V(30 Gy) (0.03% vs. 1.14%; p<0.05) and mean dose (1.35 Gy vs. 2.22 Gy; p<0.01) were significantly lower with HT, but not V(5 Gy). Contralateral breast V(5 Gy) (0.27% vs. 0.00%; p<0.01) and maximum dose were significantly increased with HT. CONCLUSIONS: In breast cancer treated with SIB, both HT and 3D-CRT provided adequate target volume coverage and low heart doses. Tumor bed coverage was slightly lower with HT, but HT avoided unnecessary breast overdosage while improving ipsilateral lung dosimetry.


Subject(s)
Breast Neoplasms/radiotherapy , Mastectomy, Segmental , Radiotherapy Dosage , Radiotherapy, Conformal , Tomography, Spiral Computed , Breast Neoplasms/pathology , Breast Neoplasms/surgery , Female , Humans , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...