Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Publication year range
1.
Radiat Prot Dosimetry ; 198(12): 815-820, 2022 Aug 26.
Article in English | MEDLINE | ID: mdl-35718757

ABSTRACT

The main purpose of this study was to determine local diagnostic reference level (LDRL) for routine computed tomography (CT) examination in Bafoussam, western Cameroon. The exposure parameters and dose quantities were collected manually. This retrospective, evaluative and comparative study was conducted to determine LDRLs for routine head CT examination in Bafoussam, to optimize these procedures in the region. The 75th percentile values of the calculated volume CT dose index (CTDIvol) and dose length product (DLP) were proposed as LDRL. The sample was classified in four age groups: < 1, 1-5, 5-10 and 10-15 y. The LDRLs obtained for the four age groups were: 24 mGy and 381.32 mGy.cm, 42.5 mGy and 875.55 mGy.cm, 45.85 mGy and 939.62 mGy.cm, 57.12 mGy and 1222.3 mGy.cm, respectively. The 75th percentile CTDIvol and DLP dose values for this study are higher than international values. We propose a coordinating discussions and collaboration about patient's and specific equipment's change information's, between radiologists, medical imaging technicians and medical physicist, which can reduce absorbed doses and improved medical practice in hospitals.


Subject(s)
Diagnostic Reference Levels , Tomography, X-Ray Computed , Cameroon , Child , Humans , Radiation Dosage , Reference Values , Retrospective Studies , Tomography, X-Ray Computed/methods
2.
Health sci. dis ; 14(4): 1-8, 2013.
Article in French | AIM (Africa) | ID: biblio-1262679

ABSTRACT

OBJECTIF. evaluer la pertinence des indications d'examens d'imagerie medicale par rapport au referentiel 'Guide du bon usage des examens d'imagerie medicale' (GBU) de la Societe Francaise de Radiologie (SFR). MeTHODOLOGIE. etude transversale descriptive portant sur l'analyse des renseignements cliniques de 262 demandes d'examens d'imagerie medicale a Yaounde (Cameroun). Les renseignements cliniques etaient categorises (symptome; syndrome; diagnostic; finalite; antecedents; aucun) puis confrontes a la mention d'indication et aux grades de recommandation du GBU de la SFR. La compatibilite entre examen demande; renseignements cliniques et qualite du demandeur etait evaluee de meme que le niveau d'irradiation. ReSULTATS. Quarante cinq (17;2) demandes n'avaient aucune indication. Le symptome etait l'indication la plus frequente (30;8). 76;3 des demandes n'avaient aucune question de recherche (finalite). La mention d'indication etait influencee par le type d'information clinique (p0.0001) avec la plus forte proportion d'examen 'indique' (80;7) lorsque la finalite de l'examen etait precisee. Dans 23 des cas l'indication fournie permettait de juger l'examen demande non-conforme. Dans 59;5 l'examen demande etait 'indique' quelque soit le niveau d'irradiation. 31 examens sans indications etaient irradiants dont 7 de niveau II et 5 de niveau III. Dans 19 cas (7;3) le demandeur n'avait pas qualite pour demander l'examen. La compatibilite examen demande - qualite du demandeur etait plus faible en TDM. CONCLUSION. Il existe une proportion importante de demandes sans indication ou sans finalite de l'examen. Pres d'un quart d'indications sont non-conformes et les symptomes constituent les indications les plus frequentes. Un systeme d'information hospitaliere avec les renseignements cliniques et la finalite de l'examen en 'cases obligatoires' contribuerait a ameliorer la prescription des examens d'imagerie


Subject(s)
Diagnosis , Image Processing, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL
...