Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
Add more filters










Publication year range
1.
J Prosthet Dent ; 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38955599

ABSTRACT

Intraoral scanners (IOSs) are digital data acquisition technologies that ease the recording of virtual diagnostic casts. Some IOSs have a specific software tool to assess volumetric changes between 2 scans acquired on the patient at different times. The scans are superimposed and volumetric differences between both meshes are reported. However, these software tools may be limited to scans captured only by the IOS of the same manufacturer. The present manuscript describes a protocol for comparing volumetric changes between 2 scans recorded using any IOS. Additionally, 1 of the scans is divided into 3 sections to minimize the alignment distortion and maximize the evaluation of the volumetric changes.

2.
J Prosthet Dent ; 2024 May 17.
Article in English | MEDLINE | ID: mdl-38762385

ABSTRACT

Jaw tracking systems can record mandibular motion for incorporation into programs used for designing dental prostheses. However, the protocol for data acquisition and design using the recorded mandibular motion is unclear. The envelope of function recorded in a patient with acceptable occlusal function provides important functional information that can be integrated into the design of dental prostheses. A protocol for recording a patient's digital data, including the envelope of function using a jaw tracker, for incorporation into the design procedures and a delivery protocol are described. This technique may simplify the delivery of prostheses by reducing the adjustments needed to the definitive prostheses.

3.
J Esthet Restor Dent ; 2024 May 22.
Article in English | MEDLINE | ID: mdl-38778662

ABSTRACT

OBJECTIVES: The purposes of this study were to classify the described digital facebow techniques for transferring the maxillary cast into the semi-adjustable virtual articulator based on the digital data acquisition technology used and to review the reported accuracy values of the different digital facebow methods described. OVERVIEW: Digital data acquisition technologies, including digital photographs, facial scanners, cone beam computed tomography (CBCT) imaging, and jaw tracking systems, can be used to transfer the maxillary cast into the virtual articulator. The reported techniques are reviewed, as well as the reported accuracy values of the different digital facebow methods. CONCLUSIONS: Digital photographs can be used to transfer the maxillary cast into the virtual articulator using the true horizontal reference plane, but limited studies have assessed the accuracy of this method. Facial scanning and CBCT techniques can be used to transfer the maxillary cast into the virtual articulator, in which the most frequently selected references planes are the Frankfort horizontal, axis orbital, and true horizontal planes. Studies analyzing the accuracy of the maxillary cast transfer by using facial scanning and CBCT techniques are restricted. Lastly, optical jaw trackers can be selected for transferring the maxillary cast into the virtual articulator by using the axis orbital or true horizontal planes, yet the accuracy of these systems is unknown. CLINICAL IMPLICATIONS: Digital data acquisition technologies, including digital photographs, facial scanning methods, CBCTs, and optical jaw tracking systems, can be used to transfer the maxillary cast into the virtual articulator. Studies are needed to assess the accuracy of these digital data acquisition technologies for transferring the maxillary cast into the virtual articulator.

4.
J Prosthet Dent ; 2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38641478

ABSTRACT

STATEMENT OF PROBLEM: Different digital methods have been described for transferring the maxillary cast into a virtual articulator; however, its accuracy remains uncertain. PURPOSE: The purpose of this in vitro study was to compare the accuracy of the maxillary cast transfer into the virtual semi-adjustable articulator by using analog and digital methods. MATERIAL AND METHODS: A maxillary typodont with 5 markers was positioned into a mannequin, which was digitized by using an industrial scanner (ATOS Q) and an extraoral scan of the typodont obtained (T710). Three groups were created based on the technique used to transfer the maxillary cast into the virtual articulator (Panadent PCH Articulator): conventional facebow record (CNV group), digital photograph (P group), and facial scanning (FS group) (n=10). In the CNV group, conventional facebow records (Kois Dentofacial analyzer system) were digitized (T710) and used to mount the maxillary scan into the articulator by aligning it with the reference platform (Kois adjustable platform) (DentalCAD). In the P group, photographs with the reference glasses (Kois Reference Glasses 3.0) were positioned in the mannequin. Each photograph was superimposed with the maxillary scan. Then, the maxillary scan was transferred into the virtual articulator by using the true horizontal plane information of the photograph. In the FS group, facial scans with an extraoral scan body (Kois Scan Body) were positioned in the mannequin by using a facial scanner (Instarisa). The extraoral scan body was digitized by using the same extraoral scanner. The digitized extraoral scan body provided the true horizontal plane information that was used to mount the maxillary scan into the articulator, along with the Kois disposable tray of the scan body. On the reference scan and each specimen, 15 linear measurements between the markers of the maxillary scans and the horizontal plane of the virtual articulator and 3 linear measurements between the maxillary dental midline and articulator midline were calculated. The measurements of the reference scan were used as a control to assess trueness and precision. Trueness was analyzed by using 1-way ANOVA followed by the pairwise comparison Tukey tests (α=.05). Precision was evaluated by using the Levene and pairwise comparisons Wilcoxon Rank sum tests. RESULTS: No significant trueness (P=.996) or precision (P=.430) midline discrepancies were found. Significant posterior right (P<.001), anterior (P=.005), posterior left (P<.001), and overall (P<.001) trueness discrepancies were revealed among the groups. The P group obtained the best posterior right, posterior left, and overall trueness and precision. The P and FS groups demonstrated the best anterior trueness, but no anterior precision discrepancies were found. CONCLUSIONS: The techniques tested affected the accuracy of the maxillary cast transfer into the virtual semi-adjustable articulator. In the majority of the parameters assessed, the photography method tested showed the best trueness and precision values. However, the maxillary cast transfer accuracy ranged from 137 ±44 µm to 453 ±176 µm among the techniques tested.

5.
J Prosthet Dent ; 2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38609764

ABSTRACT

STATEMENT OF PROBLEM: Digital photographs can be used for transferring the maxillary cast into the virtual semi-adjustable articulator; however, its accuracy remains unknown. PURPOSE: The purpose of the present study was to compare the accuracy of the maxillary cast transfer into the virtual semi-adjustable articulator by using an analog and a digital standardized photography technique. MATERIAL AND METHODS: A maxillary cast was digitized (T710) and positioned into a dental mannequin. The dental midline was not coincident with the facial midline and the maxillary occlusal plane was tilted. A reference scan of the assembled mannequin was obtained by using a facial scanner (Instarisa). Two groups were created based on the technique used to transfer the maxillary cast into the articulator (Panadent PCH): conventional facebow record (CNV group) or digital photograph (Photo group) (n=10). In the CNV group, facebow records (Kois Dentofacial analyzer system) were digitized (T710) and used to transfer the maxillary scan into the articulator by aligning it with the reference platform (Kois adjustable platform). In the Photo group, photographs with a reference glasses (Kois Reference Glasses) positioned into the mannequin were acquired. Each photograph was aligned with the maxillary scan. Then, the maxillary scan was transferred into the articulator by using the true horizontal axis information contained in the photograph. On the reference scan and each specimen, 10 linear measurements between the buccal cusps of the maxillary scan and the horizontal plane of the virtual articulator and a linear measurement between the maxillary dental midline and articulator midline were calculated. The measurements of the reference scan were used as a control to compute trueness and precision. Trueness was analyzed by using 1-way ANOVA followed by the pairwise comparison Tukey test (α=.05). Precision was evaluated by using the Levene and Wilcoxon Rank sum tests (α=.05). RESULTS: The overall discrepancy measured in the CNV group was 0.620 ±0.396 mm, while in the Photo group it was 1.282 ±0.118 mm. Significant trueness differences were found in the midline (P=.037), anterior (P=.050), posterior right (P<.001), posterior left (P=.012), and overall discrepancy (P<.001) between the CNV and Photo groups. Significant precision discrepancies were found in the midline (P=.012), posterior right (P<.001), anterior (P<.001), posterior left (P=.002), and overall discrepancy (P<.001) between the CNV and Photo groups. CONCLUSIONS: The facebow record method impacted the accuracy of the maxillary cast transfer. The Photo group obtained better trueness in the midline transfer than the CNV group; however, the CNV group demonstrated better trueness in the anterior, posterior right, posterior left, and overall discrepancy of the maxillary cast transfer compared with the Photo group. Overall, the Photo group obtained better precision than the CNV group.

6.
J Prosthet Dent ; 2024 Jan 06.
Article in English | MEDLINE | ID: mdl-38185592

ABSTRACT

Optical jaw tracking systems are designed to record the static maxillomandibular relationship and the mandibular motion of a patient, including excursive movements and mastication pattern. This digital data acquisition technology can be integrated into diagnostic and treatment planning procedures, as well as into designing dental prostheses. A step-by-step protocol to record a patient's digital data, including the repeatable reference position of the jaw or centric relation, by using an intraoral scanner, Kois deprogrammer, and optical jaw tracking system is described. The data are then processed in the software program of the jaw tracking system to locate centric occlusion.

7.
J Prosthet Dent ; 2024 Jan 11.
Article in English | MEDLINE | ID: mdl-38216378

ABSTRACT

Patients with aberrant occlusal patterns, including constricted mastication patterns or occlusal dysfunction, may require occlusal equilibration. Conventional diagnostic procedures involve diagnostic stone casts mounted in the articulator. During diagnostic procedures, occlusal equilibration methods are simulated on mounted stone casts to analyze the amount of dental structure that may need to be removed. A technique to virtually simulate an occlusal equilibration procedure is described. Digital data acquisition procedures include diagnostic casts acquired using an intraoral scanner and the repeatable reference position of the mandible or centric relation, excursive movements, and the mastication pattern captured using an optical jaw tracking system. The jaw tracker and dental design programs are used to simulate the occlusal equilibration.

8.
J Prosthet Dent ; 2024 Jan 17.
Article in English | MEDLINE | ID: mdl-38238212

ABSTRACT

Jaw tracking systems can record mandibular movement such as the repeatable reference position and excursive movements of the mandible. A technique for integrating the recorded repeatable reference position of the mandible and excursive movements captured using an optical jaw tracking system into the design procedures of an occlusal device is described. The mandibular motion of the patient is directly used to design the occlusal device, replacing the virtual articulator. The described technique aims to reduce the delivery time by incorporating the recorded motion of the patient into the virtual design of the occlusal device.

9.
J Prosthet Dent ; 2024 Jan 18.
Article in English | MEDLINE | ID: mdl-38242763

ABSTRACT

The analysis of the mandibular range of motion (ROM) includes the evaluation of maximum opening, deviation upon opening, and amplitude of the left and right excursive movements and protrusion. Conventionally, ROM assessment has been directly measured in the patient's mouth by using a ROM ruler. The development of jaw tracking systems, such as magnetometry and photometric devices, allows the digital assessment of the mandibular ROM. The present manuscript describes the clinical protocols for recording and measuring the mandibular ROM by using different jaw tracking systems.

10.
J Prosthet Dent ; 2023 Oct 03.
Article in English | MEDLINE | ID: mdl-37798183

ABSTRACT

STATEMENT OF PROBLEM: Artificial intelligence (AI) models have been developed for different applications, including the automatic design of occlusal devices; however, the design discrepancies of an experienced dental laboratory technician and these AI automatic programs remain unknown. PURPOSE: The purpose of this in vitro study was to compare the overall, intaglio, and occlusal surface discrepancies of the occlusal device designs completed by an experienced dental laboratory technician and two AI automatic design programs. MATERIAL AND METHODS: Virtually articulated maxillary and mandibular diagnostic casts were obtained in a standard tessellation language (STL) file format. Three groups were created depending on the operator or program used to design the occlusal devices: an experienced dental laboratory technician (control group) and two AI programs, namely Medit Splints from Medit (Medit group) and Automate from 3Shape A/S (3Shape group) (n=10). To minimize the discrepancies in the parameter designs among the groups tested, the same printing material and design parameters were selected. In the control group, the dental laboratory technician imported the articulated scans into a dental design program (DentalCAD) and designed a maxillary occlusal device. The occlusal device designs were exported in STL format. In the Medit and 3Shape groups, the diagnostic casts were imported into the respective AI programs. The AI programs automatically designed the occlusal device without any further operator intervention. The occlusal device designs were exported in STL format. Among the 10 occlusal designs of the control group, a random design (shuffle deck of cards) was used as a reference file to calculate the overall, intaglio, and occlusal discrepancies in the specimens of the AI groups by using a program (Medit Design). The root mean square (RMS) error was calculated. Kruskal-Wallis, and post hoc Dwass-Steel-Critchlow-Fligner pairwise comparison tests were used to analyze the trueness of the data. The Levene test was used to assess the precision data (α=.05). RESULTS: Significant overall (P<.001), intaglio (P<.001), and occlusal RMS median value (P<.001) discrepancies were found among the groups. Significant overall RMS median discrepancies were observed between the control and the Medit groups (P<.001) and the control and 3Shape groups (P<.001). Additionally, significant intaglio RMS median discrepancies were found between the control and the Medit groups (P<.001), the Medit and 3Shape groups (P<.001), and the control and 3Shape groups (P=.008). Lastly, significant occlusal RMS median discrepancies were found between the control and the 3Shape groups (P<.001) and the Medit and 3Shape groups (P<.001). The AI-based software programs tested were able to automatically design occlusal devices with less than a 100-µm trueness discrepancy compared with the dental laboratory technician. The Levene test revealed significant overall (P<.001), intaglio (P<.001), and occlusal (P<.001) precision among the groups tested. CONCLUSIONS: The use of a dental laboratory technique influenced the overall, intaglio, and occlusal trueness of the occlusal device designs obtained. No differences were observed in the precision of occlusal device designs acquired among the groups tested.

11.
J Esthet Restor Dent ; 35(5): 810-814, 2023 07.
Article in English | MEDLINE | ID: mdl-37162127

ABSTRACT

OBJECTIVE: To describe a technique for fabricating an additively manufactured maxillary occlusal device using a complete digital workflow. CLINICAL CONSIDERATIONS: The maxillary occlusal device design may include an anterior platform to guide the positioning of the mandible in a reproducible position for facilitating the delivery procedure. CONCLUSIONS: The described technique provides a more efficient and less time-consuming method for designing and manufacturing a printed occlusal device, when compared with conventional fabrication techniques. CLINICAL SIGNIFICANCE: The additively manufactured occlusal device designed with an anterior platform guides the positioning of the mandible in a reproducible position, facilitates the delivery procedures, and produces a more efficient and less time-consuming method when compared with conventional methods.


Subject(s)
Mandible , Occlusal Adjustment , Maxilla , Workflow
12.
J Esthet Restor Dent ; 35(5): 735-744, 2023 07.
Article in English | MEDLINE | ID: mdl-37021739

ABSTRACT

OBJECTIVES: Within the development of digital technologies, dental professionals aim to integrate virtual diagnostic articulated casts obtained by using intraoral scanners (IOSs), the mandibular motion of the patient recorded by using an optical jaw tracking system, and the information provided by computerized occlusal analysis systems. This article describes the various digital technologies available for obtaining the digital occlusion of a patient and outlines its challenges and limitations. OVERVIEW: The factors that influence the accuracy of the maxillomandibular relationship of diagnostic casts obtained by using IOSs are reviewed, as well as the occurrence of occlusal collisions or mesh interpenetrations. Different jaw tracking systems with varying digital technologies including ultrasonic systems, photometric devices, and artificial intelligence algorithms are reviewed. Computerized occlusal analysis systems for detecting occlusal contacts in a time sequential manner with the pressure distribution on the occlusal surfaces are reviewed. CONCLUSIONS: Digital technologies provide powerful diagnostic and design tools for prosthodontic care. However, the accuracy of these digital technologies for acquiring and analyzing the static and dynamic occlusion need to be further analyzed. CLINICAL SIGNIFICANCE: Efficiently implementing digital technologies into dental practice requires an understanding of the limitations and state of current development of the digital acquisition methods for digitizing the static and dynamic occlusion of a patient by using IOSs, digital jaw trackers, and computerized occlusal analysis devices.


Subject(s)
Artificial Intelligence , Digital Technology , Humans , Dental Occlusion , Mandible , Models, Dental , Imaging, Three-Dimensional/methods , Computer-Aided Design , Dental Impression Technique
13.
J Prosthet Dent ; 2023 Mar 03.
Article in English | MEDLINE | ID: mdl-36872156

ABSTRACT

STATEMENT OF PROBLEM: The accuracy of intraoral scanners (IOSs) can be affected by operator handling; however, the scanning area and accuracy discrepancies acquired at different scanning distances and angulations among IOSs remain uncertain. PURPOSE: The objective of this in vitro study was to compare the scanning area and scanning accuracy of the intraoral digital scans obtained at 3 scanning distances with 4 different scanning angulations among 4 different IOSs. MATERIAL AND METHODS: A reference device (reference file) was designed with 4 inclinations (0, 15, 30, and 45 degrees) and printed. Four groups were created based on the IOS: i700, TRIOS4, CS 3800, and iTero scanners. Four subgroups were generated depending on the scanning angulation (0, 15, 30, and 45 degrees). Each subgroup was divided into 3 subgroups based on the scanning distance: 0, 2, and 4 mm (N=720, n=15). The reference devices were positioned in a z-axis calibrated platform for standardizing the scanning distance. In the i700-0-0 subgroup, the 0-degree reference device was positioned in the calibrated platform. The wand of the IOS was positioned in a supporting framework with a 0-mm scanning distance, and the scans were acquired. In the i700-0-2 subgroup, the platform was lowered for a 2-mm scanning distance followed by the specimen acquisition. In the i700-0-4 subgroup, the platform was further lowered for a 4-mm scanning distance, and the scans were obtained. For the i700-15, i700-30, and i700-45 subgroups, the same procedures were carried out as in the i700-0 subgroups respectively, but with the 10-, 15-, 30-, or 45-degree reference device. Similarly, the same procedures were completed for all the groups with the corresponding IOS. The area of each scan was measured. The reference file was used to measure the discrepancy with the experimental scans by using the root mean square (RMS) error. Three-way ANOVA and post hoc Tukey pairwise comparison tests were used to analyze the scanning area data. Kruskal-Wallis and multiple pairwise comparison tests were used to analyze the RMS data (α=.05). RESULTS: IOS (P<.001), scanning distance (P<.001), and scanning angle (P<.001) were significant factors of the scanning area measured among the subgroups tested. A significant group×subgroup interaction was found (P<.001). The iTero and the TRIOS4 groups obtained higher scanning area mean values than the i700 and CS 3800 groups. The CS 3800 obtained the lowest scanning area among the IOS groups tested. The 0-mm subgroups obtained a significantly lower scanning area than the 2- and 4-mm subgroups (P<.001). The 0- and 30-degree subgroups obtained a significantly lower scanning area than the 15- and 45-degree subgroups (P<.001). The Kruskal-Wallis test revealed significant median RMS discrepancies (P<.001). All the IOS groups were significantly different from each other (P<.001), except for the CS 3800 and TRIOS4 groups (P>.999). All the scanning distance groups were different from each other (P<.001). CONCLUSIONS: Scanning area and scanning accuracy were influenced by the IOS, scanning distance, and scanning angle selected to acquire the digital scans.

14.
J Prosthet Dent ; 2023 Jan 10.
Article in English | MEDLINE | ID: mdl-36635137

ABSTRACT

STATEMENT OF PROBLEM: Different factors can affect the manufacturing accuracy of additively manufactured dental devices; however, the influence of print orientation and wet-dry storage time on their intaglio accuracy remains uncertain. PURPOSE: The purpose of this in vitro study was to assess the effect of print orientation (0, 45, 70, and 90 degrees) and wet-dry storage time (0, 30, 60, and 90 days) on the intaglio accuracy of additively manufactured occlusal devices. MATERIAL AND METHODS: An occlusal device design was obtained in a standard tessellation language (STL) file format (control file) which was used to fabricate all the specimens by using a stereolithography printer (Form 3+) and a biocompatible resin material (Dental LT Clear Resin, V2). Four groups were created based on the print orientation used to manufacture the specimens: 0, 45, 70, and 90 degrees. Each group was divided into 4 subgroups depending on the time elapsed between manufacturing and accuracy evaluation: 0, 30, 60, and 90 days. For the subgroup 0, a desktop scanner (T710) was used to digitize all the specimens. The 30-day subgroup specimens were stored for 30 days with the following daily storage protocol: 16 hours inside a dry lightproof container, followed by 8 hours in artificial saliva (1700-0305 Artificial Saliva) inside the same lightproof container. The specimens were then digitized by following the same procedures used for subgroup 0. For the subgroups 60 and 90, the identical procedures described for subgroup 30 were completed but after 60 and 90 days of storage, respectively. The reference STL file was used to measure the intaglio discrepancy with the experimental scans obtained among the different subgroups by using the root mean square error calculation. Two-way ANOVA and post hoc Tukey pairwise comparison tests were used to analyze the data (α=.05). RESULTS: Print orientation (P<.001) and usage time (P<.001) were significant predictors of the trueness value obtained. Additionally, the 0-degree print orientation at day 0 group demonstrated the best trueness value among all the groups tested (P<.05). No significant trueness discrepancies were found among the 45-, 70-, and 90-degree print orientation, or among the 30, 60, and 90 days of storage. A significant precision difference was found in the variance between print orientation groups across usage time subgroups. CONCLUSIONS: The print orientation and wet-dry storage times tested influenced the trueness and precision of the intaglio surfaces of the occlusal devices manufactured with the 3D printer and material selected.

15.
J Prosthet Dent ; 2023 Jan 20.
Article in English | MEDLINE | ID: mdl-36682896

ABSTRACT

STATEMENT OF PROBLEM: Digital systems including intraoral scanners (IOSs) and optical jaw tracking systems can be used to acquire the maxillomandibular relationship at the centric relation (CR). However, the discrepancy of the maxillomandibular relationship recorded at the CR position when using digital methods remains uncertain. PURPOSE: The purpose of this clinical study was to compare the accuracy of the maxillomandibular relationship recorded at the CR position using a conventional procedure, 4 different IOSs, and an optical jaw tracking system. MATERIAL AND METHODS: A completely dentate volunteer was selected. A Kois deprogrammer (KD) was fabricated. Six groups were created based on the technique used to obtain diagnostic casts and record the maxillomandibular relationship at the CR position: conventional procedures (CNV group), 4 IOS groups: TRIOS4 (TRIOS4 group), iTero Element 5D (iTero group), i700 wireless (i700 group), Primescan (Primescan group), and a jaw tracking system (Modjaw) (Modjaw group) (n=10). In the CNV group, conventional diagnostic stone casts were obtained. A facebow record was used to mount the maxillary cast on an articulator (Panadent). The KD was used to obtain a CR record for mounting the mandibular cast, and the mounted casts were digitized by using a scanner (T710) to acquire the reference scans. In the TRIOS group, intraoral scans were obtained and duplicated 10 times. The KD was used to obtain a bilateral virtual occlusal record at the CR position. To acquire the specimens of the iTero, i700, and Primescan groups, the procedures in the TRIOS4 group were followed, but with the corresponding IOS. In the Modjaw group, the KD was used to record and export the maxillomandibular relationship at the CR position. Articulated virtual casts of each group were exported. Thirty-six interlandmark linear measurements were computed on both the reference and experimental scans. The distances obtained on the reference scan were used to calculate the discrepancies with the distances obtained on each experimental scan. The data were analyzed by using 1-way ANOVA followed by the pairwise comparison Tukey tests (α=.05). RESULTS: The trueness and precision of the maxillomandibular relationship record were significantly affected by the technique used (P<.001). The maxillomandibular relationship trueness values from high to low were iTero (0.14 ±0.09 mm), followed by the Modjaw (0.20 ±0.04 mm) and the TRIOS4 (0.22 ±0.09 mm) groups. However, the iTero, Modjaw, and TRIOS4 groups were not significantly different from each other (P>.05). The i700 group obtained the lowest trueness and precision values (0.40 ±0.22 mm) of all groups tested, followed by the Primescan grop (0.26±0.13 mm); however, the i700 and Primescan groups had significantly lower trueness and precision than only the iTero group (P<.05). CONCLUSIONS: The trueness and precision of the maxillomandibular relationship recorded at the CR position were influenced by the different digital techniques tested.

16.
J Prosthet Dent ; 2022 Oct 27.
Article in English | MEDLINE | ID: mdl-36349566

ABSTRACT

STATEMENT OF PROBLEM: The accuracy of a maxillomandibular relationship acquired by intraoral scanners (IOSs) has been previously analyzed; however, the impact of the interocclusal space on the accuracy of the maxillomandibular relationship remains unknown. PURPOSE: The purpose of this in vitro investigation was to evaluate the influence of the interocclusal space (0, 1, 2, 3, or 4 degrees of incisal opening in the articulator) on the accuracy of the maxillomandibular relationship captured with an IOS. MATERIAL AND METHODS: Markers were attached to the first molars and canines of maxillary and mandibular diagnostic casts, which were mounted on a semi-adjustable articulator, and digital scans were acquired (TRIOS 4). Both digital scans were duplicated 100 times and distributed into 5 groups depending on the incisal pin opening in the articulator (n=20): 0 (Group 0), 1 (Group 1), 2 (Group 2), 3 (Group 3), and 4 degrees (Group 4). In Group 0 (control), the casts were maintained in maximum intercuspation (MIP) with the incisal pin of the articulator set at 0 degrees. Then, a bilateral virtual occlusal record was acquired and automatically processed by using the IOS software program. A laboratory scanner (Medit T500) was used to digitize the mounted casts. The same procedures were completed in Groups 1, 2, 3, and 4 but with the incisal pin set at 1, 2, 3, and 4 degrees respectively. The interlandmark distances were used to calculate the discrepancies between the control and groups tested. One-way analysis of variance (ANOVA) and pairwise comparison Tukey HSD tests were used to inspect the data (α=.05). RESULTS: The interocclusal space available when capturing the occlusal records affected the trueness of the maxillomandibular virtual relationship measured (P<.001). Group 0 (135 µm) obtained the highest distortion, while Group 3 (73 µm) and Group 4 (71 µm) showed the lowest distortion. Additionally, the interocclusal space available (P<.001) impacted the precision of the maxillomandibular virtual relationship measured. Group 0 (111 µm) obtained the highest distortion, while Group 4 (precision mean value of 59 µm) had the lowest distortion among the groups tested. CONCLUSIONS: The interocclusal space available when acquiring virtual bilateral occlusal records using the IOS tested impacted the accuracy of the maxillomandibular relationship. The smallest available interocclusal space tested (maximum intercuspation) showed the worst trueness and precision mean values, while the group with the largest interocclusal space available had the highest trueness and precision mean values among the groups studied.

17.
J Prosthet Dent ; 2022 Aug 05.
Article in English | MEDLINE | ID: mdl-35934572

ABSTRACT

A technique for fabricating an additively manufactured Kois deprogrammer is described from the initial patient data collection with an intraoral scanner to the 3D printing methods to fabricate the device. The incorporation of digital technologies for manufacturing a Kois deprogrammer provides new clinical and manufacturing tools, providing more efficient and less time-consuming design and manufacturing techniques than conventional techniques while maintaining conventional prosthodontic concepts.

18.
J Prosthet Dent ; 2022 Aug 16.
Article in English | MEDLINE | ID: mdl-35985852

ABSTRACT

A technique for digitally recording the maxillomandibular relationship, including the maximum intercuspation and centric occlusion and the patient's mandibular motion, by using an optical jaw tracking system is described. Advantages of this technique include the digital registration of the maxillomandibular relationship and mandibular motion. This technique incorporates the mandibular motion into the 3-dimensional (3D) virtual patient representation to integrate the 3D dynamic virtual patient visualization.

19.
J Prosthodont ; 31(8): 728-733, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35852960

ABSTRACT

A step-by-step technique is described for tracking and recording, in real time, the lip dynamics of a patient and integrating them into a 3D virtual patient representation using facial trackers and motion engine software programs. The main advantage of this technique is that it enables capturing of the lip movements of the patient in real time; therefore, the lip movements are not simulated from a previously recorded video of the patient using animation software programs.


Subject(s)
Lip , Humans , Face , Movement , Software , Imaging, Three-Dimensional
20.
J Prosthet Dent ; 2022 Jun 04.
Article in English | MEDLINE | ID: mdl-35672165

ABSTRACT

Various techniques have been developed for a 3-dimensional (3D) virtual patient. However, those techniques do not enable the registration of the alignment of the facial and intraoral digital scans, the registration for the mounting on the virtual articulator, and the integration of the natural head position (NHP) together. In the present manuscript, a scan body system is described that assists with the translation of the horizon orientation within the NHP of the patient into a computer-aided design software program. Additionally, the scan body system facilitates the facial and intraoral alignment, as well as the mounting of the maxillary virtual cast on the virtual articulator. This scan body system facilitates the integration of the 3D virtual patient and reduces chair and laboratory time.

SELECTION OF CITATIONS
SEARCH DETAIL
...