Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 45
Filter
1.
Article in English | MEDLINE | ID: mdl-38687136

ABSTRACT

Background: Recent studies show e-cigarette (EC) users have increased rates of chronic bronchitic symptoms that may be associated with depressed mucociliary clearance (MCC). Little is known about the acute or chronic effects of EC inhalation on in vivo MCC. Methods: In vivo MCC was measured in young adult vapers (n = 5 males, mean age = 21) after controlled inhalation of a radiolabeled (Tc99m sulfur colloid) aerosol. Whole-lung clearance of radiolabeled deposited particles was measured over a 90-minute period for baseline MCC and associated with controlled periodic vaping over the first 60 minutes of MCC measurements. The vaping challenge was administered from a fourth generation box mod EC containing unflavored e-liquid (65% propylene glycol/35% vegetable glycerin, 3 mg/mL freebase nicotine). The challenge was administered at the start of each 10-minute interval of MCC measurements and consisted of 1 puff every 30 seconds for 5 minutes (i.e., 10 puffs for each 10-minute period for a total of 60 puffs during the initial 60 minutes of MCC measurements). Results: Compared with baseline, peripheral lung average clearance (%) over the 90 minutes of MCC measures was enhanced, associated with EC challenge, 12 (±6) versus 24 (±6), respectively (p < 0.05 by Wilcoxon signed-rank test). Conclusions: Acute enhancement of in vivo MCC during EC challenge is contrary to recent studies showing nicotine-associated slowing of ciliary beat and mucus transport at higher nicotine levels than those used here. However, our findings are consistent with an acute increase in fluid volume and mucin secretion to the bronchial airway surface that is likely short lived. Research reported in this publication was supported by the National Institutes of Health R01HL139369 and registered with ClinicalTrials.gov (NCT03700892).

2.
J Cyst Fibros ; 2024 Feb 13.
Article in English | MEDLINE | ID: mdl-38355350

ABSTRACT

Many people with CF (pwCF) desire a reduction in inhaled treatment burden after initiation of elexacaftor/tezacaftor/ivacaftor. The randomized, open-label SIMPLIFY study showed that discontinuing hypertonic saline (HS) or dornase alfa (DA) was non-inferior to continuation of each treatment with respect to change in lung function over a 6-week period. In this SIMPLIFY substudy, we used gamma scintigraphy to determine whether discontinuation of either HS or DA was associated with deterioration in the rate of in vivo mucociliary clearance (MCC) in participants ≥12 years of age. While no significant differences in MCC endpoints were associated with HS discontinuation, significant improvement in whole and peripheral lung MCC was observed after discontinuing DA. These results suggest that pwCF on ETI with mild lung disease do not experience a subclinical deterioration in MCC that could later impact health outcomes after discontinuing HS, and in fact may benefit from improved MCC after stopping DA treatment.

3.
J Cyst Fibros ; 23(1): 155-160, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37845149

ABSTRACT

BACKGROUND: The cystic fibrosis transmembrane conductance regulator (CFTR) modulator elexacaftor/tezacaftor/ivacaftor (E/T/I) is highly effective clinically for those with at least one F508del-CFTR allele. The effects of E/T/I on mucociliary clearance (MCC) and sputum properties are unknown. We, therefore, sought to characterize the effects of E/T/I on in vivo MCC and sputum characteristics hypothesized to impact mucus transport. METHODS: Forty-four participants ≥12 years of age were enrolled into this prospective, observational trial prior to initiation of E/T/I and had baseline measurement of MCC and characterization of induced sputum and exhaled breath condensate (EBC) samples. Study procedures were repeated after 1 month of E/T/I treatment. RESULTS: Average age was 27.7 years with baseline forced expiratory volume in 1 second (FEV1) of 78.2 % predicted. 52 % of subjects had previously been treated with a 2-drug CFTR modulator combination. The average whole lung MCC rate measured over 60 min (WLAveClr60) significantly improved from baseline to post-E/T/I (14.8 vs. 22.8 %; p = 0.0002), as did other MCC indices. Sputum% solids also improved (modeled mean 3.4 vs. 2.2 %; p<0.0001), whereas non-significant reductions in sputum macrorheology (G', G") were observed. No meaningful changes in exhaled breath condensate endpoints (sialic acid:urea ratio, pH) were observed. CONCLUSIONS: E/T/I improved the hydration of respiratory secretions (% solids) and markedly accelerated MCC. These data confirm the link between CFTR function, mucus solid content, and MCC and help to define the utility of MCC and mucus-related bioassays in future efforts to restore CFTR function in all people with CF.


Subject(s)
Cystic Fibrosis , Indoles , Pyrazoles , Pyridines , Pyrrolidines , Quinolones , Humans , Adult , Cystic Fibrosis/diagnosis , Cystic Fibrosis/drug therapy , Cystic Fibrosis/genetics , Cystic Fibrosis Transmembrane Conductance Regulator , Mucociliary Clearance , Prospective Studies , Aminophenols/therapeutic use , Benzodioxoles/therapeutic use , Mucus , Mutation , Chloride Channel Agonists/therapeutic use
4.
Infect Control Hosp Epidemiol ; 44(9): 1481-1484, 2023 09.
Article in English | MEDLINE | ID: mdl-36912322

ABSTRACT

BACKGROUND: Face masks reduce disease transmission by protecting the wearer from inhaled pathogens and reducing the emission of infectious aerosols. Although methods quantifying efficiency for wearer protection are established, current methods for assessing face mask containment efficiency rely on measurement of a low concentration of aerosols emitted from an infected or noninfected individual. METHODS: A small port enabled the introduction of 0.05 µm sodium chloride particles at a constant rate behind the mask worn by a study participant. A condensation particle counter monitored ambient particle numbers 60 cm in front of the participant over 3-minute periods of rest, speaking, and coughing. The containment efficiency (%) for each mask and procedure was calculated as follows: 100 × (1 - average ambient concentration with face covering worn/average ambient concentration with a sham face covering in place). The protection efficiency (%) was also measured using previously published methods. The probability of transmission (%) from infected to uninfected (a function of both the containment efficiency and the protection efficiency) was calculated as follows: {1 - (containment efficiency/100)}×{1 - (protection efficiency/100)}×100. RESULTS: The average containment efficiencies for each mask over all procedures and repeated measures were 94.6%, 60.9%, 38.8%, and 43.2%, respectively, for the N95 mask, the KN95 mask, the procedure face mask, and the gaiter. The corresponding protection efficiencies for each mask were 99.0%, 63.7%, 45.3%, and 24.2%, respectively. For example, the transmission probability for 1 infected and 1 uninfected individual in close proximity was ∼14.2% for KN95 masks, compared to 36%-39% when only 1 individual wore a KN95 mask. CONCLUSION: Overall, we detected a good correlation between the protection and containment that a face covering afforded to a wearer.


Subject(s)
Respiratory Aerosols and Droplets , Respiratory Protective Devices , Humans , N95 Respirators , Masks , Cough
5.
Compr Physiol ; 12(4): 3823-3832, 2022 08 12.
Article in English | MEDLINE | ID: mdl-35959754

ABSTRACT

Total and regional deposition of inhaled electronic cigarette (E-cig) particles in the respiratory tract (RT) depends on both physical properties of the inhaled particles and biological factors of users, for example, breathing pattern or puff profile, airway anatomy, and regional ventilation. Accurate particle sizing of E-cig aerosols is essential for predicting particle deposition in the RT. Studies using a variety of sizing methods have shown mass median aerodynamic diameters ranging from 0.2 to 1.2 um and secondary count diameters in the ultrafine range (<0.1 µm). Incorporating these particle sizes into a multiple-path particle dosimetry (MPPD) model shows 10% to 45% total lung deposition by mass and 30% to 80% for ultrafine particles depending on the breathing patterns. These predictions are consistent with experimental measures of deposition fraction of submicron and ultrafine particles. While box-mod-type E-cig devices allow for full "direct-lung" inhalations of aerosol, the more recent pod-based, and disposable E-cigs (e.g., JUUL, Puff Bar, Stig) deliver the aerosol as a "mouth-to-lung" puff, or bolus, that is inhaled early in the breath followed to various degrees by further inhalation of ambient air. Measurement of realistic ventilation patterns associated with these various devices may further improve deposition predictions. Finally, while in vivo measures of RT deposition present a challenge, a recent methodology to radiolabel E-cig particles may allow for such measurements by gamma scintigraphy. Supported by NIH/NHLBI R01HL139369. © 2022 American Physiological Society. Compr Physiol 12: 1-10, year.


Subject(s)
Electronic Nicotine Delivery Systems , Administration, Inhalation , Aerosols , Humans , Lung/diagnostic imaging , Particulate Matter , Respiratory System/diagnostic imaging
6.
PLoS One ; 17(5): e0268622, 2022.
Article in English | MEDLINE | ID: mdl-35594286

ABSTRACT

BACKGROUND: Cystic fibrosis (CF) is an inherited disorder causing impaired mucociliary clearance within the respiratory tract, and is associated with bronchiectasis, chronic respiratory infections, and early death. Airway clearance therapies have long been a cornerstone of management of individuals with CF, although evidence supporting their use is lacking. We designed a randomized controlled trial to quantitatively compare the effects of different forms of airway clearance on mucociliary clearance. METHODS: Three different physiotherapy methods to augment cough-clearance were studied in addition to cough-clearance alone: high-frequency chest-wall oscillating vest, oscillatory positive expiratory pressure, and whole-body vibration. We used gamma scintigraphy after inhalation of radiolabeled particles to quantify mucus clearance before, during, and after physiotherapy. As secondary endpoints, we measured concentrations of small molecules in exhaled breath that may impact mucus clearance. RESULTS: Ten subjects were enrolled and completed study procedures. No differences were identified between any method of airway clearance, including cough clearance alone. We did identify changes in certain small molecule concentrations in exhaled breath following airway clearance. CONCLUSIONS: Due to the limitations of this study, we do not believe the negative results suggest a change in clinical practice with regard to airway clearance. Findings pertaining to small molecules in exhaled breath may serve as future opportunities for study.


Subject(s)
Cystic Fibrosis , Mucociliary Clearance , Adult , Cough/complications , Cystic Fibrosis/complications , Forced Expiratory Volume , Humans , Mucus
7.
Am J Infect Control ; 49(9): 1206-1209, 2021 09.
Article in English | MEDLINE | ID: mdl-33971283

ABSTRACT

Shortages of efficient filtering facepiece respirators leave the public vulnerable to transmission of infectious diseases in small particle aerosols. This study demonstrates that a high-filtration-efficiency facepiece capable of filtering out >95% of 0.05µm particles while being worn can be simply produced with available materials.


Subject(s)
Occupational Exposure , Respiratory Protective Devices , Aerosols , Filtration , Humans , Ventilators, Mechanical
8.
J Expo Sci Environ Epidemiol ; 31(6): 953-960, 2021 11.
Article in English | MEDLINE | ID: mdl-34006963

ABSTRACT

BACKGROUND: Globally, a large percentage of men keep a beard at least occasionally. Workplace regulations prohibit beards with N95 respirators, but there is little information on the effect of beards with face masks worn by the public for protection against SARS-CoV-2. METHODS AND FINDINGS: We examined the fitted filtration efficiency (FFE) of five commonly worn protective face masks as a function of beard length following the US Occupational Safety and Health Administration Quantitative Fit Test: N95 (respirator), KF94 and KN95, surgical/procedure, and cloth masks. A comparison using N95 respirators was carried out in shaven and bearded men. A detailed examination was conducted for beard lengths between 0 and 10 mm (0.5 mm increments). The effect of an exercise band covering the beard on FFE was also tested. Although N95 respirators showed considerable variability among bearded men, they had the highest FFE for beard lengths up to 10 mm. KF94 and KN95 masks lost up to 40% of their FFE. Procedure and cotton masks had poor performance even on bare skin (10-30% FFE) that did not change appreciably with beard length. Marked performance improvements were observed with an exercise band worn over the beard. CONCLUSIONS: Though variable, N95 respirators offer the best respiratory protection for bearded men. While KF94 and KN95 FFE is compromised considerably by increasing beard length, they proved better options than procedure and cotton face masks. A simple exercise band improves FFE for face masks commonly used by bearded men during the COVID-19 pandemic.


Subject(s)
COVID-19 , Respiratory Protective Devices , Humans , Male , Masks , Pandemics/prevention & control , Personal Protective Equipment , SARS-CoV-2
10.
JAMA Intern Med ; 181(4): 463-469, 2021 04 01.
Article in English | MEDLINE | ID: mdl-33300948

ABSTRACT

Importance: During the coronavirus disease 2019 (COVID-19) pandemic, the general public has been advised to wear masks or improvised face coverings to limit transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). However, there has been considerable confusion and disagreement regarding the degree to which masks protect the wearer from airborne particles. Objectives: To evaluate the fitted filtration efficiency (FFE) of various consumer-grade and improvised face masks, as well as several popular modifications of medical procedure masks that are intended to improve mask fit or comfort. Design, Setting, and Participants: For this study conducted in a research laboratory between June and August 2020, 7 consumer-grade masks and 5 medical procedure mask modifications were fitted on an adult male volunteer, and FFE measurements were collected during a series of repeated movements of the torso, head, and facial muscles as outlined by the US Occupational Safety and Health Administration Quantitative Fit Testing Protocol. The consumer-grade masks tested included (1) a 2-layer nylon mask with ear loops that was tested with an optional aluminum nose bridge and filter insert in place, (2) a cotton bandana folded diagonally once (ie, "bandit" style) or in a (3) multilayer rectangle according to the instructions presented by the US Surgeon General, (4) a single-layer polyester/nylon mask with ties, (5) a polypropylene mask with fixed ear loops, (6) a single-layer polyester gaiter/neck cover balaclava bandana, and (7) a 3-layer cotton mask with ear loops. Medical procedure mask modifications included (1) tying the mask's ear loops and tucking in the side pleats, (2) fastening ear loops behind the head with 3-dimensional-printed ear guards, (3) fastening ear loops behind the head with a claw-type hair clip, (4) enhancing the mask/face seal with rubber bands over the mask, and (5) enhancing the mask/face seal with a band of nylon hosiery over the fitted mask. Main Outcomes and Measures: The primary study outcome was the measured FFE of common consumer-grade and improvised face masks, as well as several popular modifications of medical procedure masks. Results: The mean (SD) FFE of consumer grade masks tested on 1 adult male with no beard ranged from 79.0% (4.3%) to 26.5% (10.5%), with the 2-layer nylon mask having the highest FFE. Unmodified medical procedure masks with ear loops had a mean (SD) FFE of 38.5% (11.2%). All modifications evaluated in this study increased procedure mask FFE (range [SD], 60.3% [11.1%] to 80.2% [3.1%]), with a nylon hosiery sleeve placed over the procedure mask producing the greatest improvement. Conclusions and Relevance: While modifications to improve medical procedure mask fit can enhance the filtering capability and reduce inhalation of airborne particles, this study demonstrates that the FFEs of consumer-grade masks available to the public are, in many cases, nearly equivalent to or better than their non-N95 respirator medical mask counterparts.


Subject(s)
COVID-19/prevention & control , COVID-19/transmission , Masks , Adult , Cotton Fiber , Equipment Design , Filtration/instrumentation , Humans , Male , Nylons , Polyesters , Polypropylenes , Protective Clothing
11.
ERJ Open Res ; 6(3)2020 Jul.
Article in English | MEDLINE | ID: mdl-32802823

ABSTRACT

BACKGROUND: Mucus dehydration and impaired mucus clearance are common features of cystic fibrosis (CF) and chronic obstructive pulmonary disease (COPD). In CF, inhaled hypertonic saline (HS) improves lung function and produces sustained increases in mucociliary clearance (MCC). We hypothesised that administration of HS (7% NaCl) twice daily for 2 weeks would improve clinical outcomes and produce sustained increases in MCC in COPD subjects with a chronic bronchitis (CB) phenotype. METHODS: Twenty-two CB subjects completed a double-blinded, crossover study comparing inhaled HS to a hypotonic control solution (0.12% saline) administered via nebuliser twice daily for 2 weeks. Treatment order was randomised. During each treatment period, symptoms and spirometry were measured. MCC was measured at baseline, shortly after initial study agent administration, and approximately 12 h after the final dose. RESULTS: HS was safe and well tolerated but overall produced no significant improvements in spirometry or patient-reported outcomes. CB subjects had slower baseline MCC than healthy subjects. The MCC rates over 60 min (Ave60Clr) in CB subjects following 2 weeks of HS were not different from 0.12% saline but were slower than baseline (Ave60Clr was 9.1±6.3% at baseline versus 5.3±6.9% after HS; p<0.05). Subgroup analyses determined that subjects with residual baseline central lung clearance (14 subjects) had improved spirometry and symptoms following treatment with HS, but not 0.12% saline, treatment. CONCLUSIONS: Inhaled HS appeared to be safe in a general CB population. A specific phenotypic subgroup may benefit from HS but requires additional study.

12.
JAMA Intern Med ; 180(12): 1607-1612, 2020 12 01.
Article in English | MEDLINE | ID: mdl-32780113

ABSTRACT

Importance: Procuring respiratory protection for clinicians and other health care workers has become a major challenge of the coronavirus disease 2019 (COVID-19) pandemic and has resulted in nonstandard practices such as the use of expired respirators and various decontamination processes to prolong the useful life of respirators in health care settings. In addition, imported, non-National Institute for Occupational Safety and Health (NIOSH)-approved respirators have been donated or acquired by hospitals as a potential replacement for limited NIOSH-approved N95 respirators. Objective: To assess fitted filtration efficiencies (FFEs) for face mask alternatives used during the COVID-19 pandemic. Design, Setting, and Participants: For this quality-improvement study conducted between April and June 2020, we used the Occupational Safety and Health Administration's Quantitative Fit Testing Protocol for Filtering Facepiece Respirators in a laboratory atmosphere supplemented with sodium chloride particles to assess the FFEs of a variety of respirators worn by a male volunteer and female volunteer. Main Outcomes and Measures: The FFEs of respirators commonly worn by clinicians and other health care workers and available respirator alternatives during the COVID-19 pandemic. Results: Of the 29 different fitted face mask alternatives tested on 1 man and 1 woman, expired N95 respirators with intact elastic straps and respirators subjected to ethylene oxide and hydrogen peroxide sterilization had unchanged FFE (>95%). The performance of N95 respirators in the wrong size had slightly decreased performance (90%-95% FFE). All of the respirators not listed as approved in this evaluation (n = 6) failed to achieve 95% FFE. Neither of the 2 imported respirators authorized for use by the Centers for Disease Control and Prevention that were not NIOSH-approved tested in this study achieved 95% FFE, and the more effective of the 2 functioned at approximately 80% FFE. Surgical and procedural face masks had filtering performance that was lower relative to that of N95 respirators (98.5% overall FFE), with procedural face masks secured with elastic ear loops showing the lowest efficiency (38.1% overall FFE). Conclusions and Relevance: This quality-improvement study evaluating 29 face mask alternatives for use by clinicians interacting with patients during the COVID-19 pandemic found that expired N95 respirators and sterilized, used N95 respirators can be used when new N95 respirators are not available. Other alternatives may provide less effective filtration.


Subject(s)
COVID-19 , Equipment Reuse/standards , Filtration/standards , Infection Control/instrumentation , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Masks , N95 Respirators , Sterilization , COVID-19/epidemiology , COVID-19/prevention & control , COVID-19/transmission , Disinfectants , Equipment Contamination/prevention & control , Equipment Failure Analysis/methods , Ethylene Oxide/pharmacology , Health Personnel , Humans , Hydrogen Peroxide/pharmacology , Masks/classification , Masks/standards , Masks/supply & distribution , Materials Testing/methods , N95 Respirators/standards , N95 Respirators/supply & distribution , Quality Improvement , SARS-CoV-2 , Sterilization/methods , Sterilization/standards
13.
J Cyst Fibros ; 19(6): 942-948, 2020 11.
Article in English | MEDLINE | ID: mdl-32669217

ABSTRACT

BACKGROUND: Hypertonic saline (HS) is commonly prescribed for children with cystic fibrosis (CF) despite the absence of strong data indicating clinical efficacy in a population with mild lung disease. We hypothesized that HS treatment would result in a sustained improvement in mucociliary clearance (MCC) in children with CF who had minimal lung disease, thus providing evidence for a biologically relevant effect that also may be associated with clinical improvements. METHODS: We performed a randomized, placebo controlled, double blind study of 6% versus 0.12% sodium chloride, delivered three-times daily with an eFlow nebulizer for 4 weeks. MCC was measured using gamma scintigraphy at baseline, 2-hours after the first study treatment, and ~12-hours after the final dose (at day 28). Spirometry, respiratory symptoms (CFQ-R), and safety were also assessed. RESULTS: Study treatments were generally well tolerated and safe. HS (6% sodium chloride) resulted in a significant, sustained improvement from baseline in whole lung clearance after 4 weeks of therapy (p = 0.014), despite absence of a prolonged single-dose effect after the initial dose. This sustained change (12 hrs after prior dose) was significantly greater when compared to placebo (0.12% sodium chloride) treatment (p = 0.016). Improvements in spirometry with HS did not reach statistical significance but correlated with MCC changes. CONCLUSIONS: The observed sustained improvement in MCC with HS suggests that this treatment may yield health benefits, even in relatively mildly affected children with CF. Highlighting this physiologic finding is important due to the lack of meaningful, validated endpoints in this population.


Subject(s)
Cystic Fibrosis/drug therapy , Mucociliary Clearance/drug effects , Saline Solution, Hypertonic/administration & dosage , Administration, Inhalation , Child , Double-Blind Method , Female , Humans , Male , Nebulizers and Vaporizers
14.
Am J Hum Genet ; 104(2): 229-245, 2019 02 07.
Article in English | MEDLINE | ID: mdl-30665704

ABSTRACT

Primary ciliary dyskinesia (PCD) is a genetic disorder in which impaired ciliary function leads to chronic airway disease. Exome sequencing of a PCD subject identified an apparent homozygous frameshift variant, c.887_890delTAAG (p.Val296Glyfs∗13), in exon 5; this frameshift introduces a stop codon in amino acid 308 of the growth arrest-specific protein 2-like 2 (GAS2L2). Further genetic screening of unrelated PCD subjects identified a second proband with a compound heterozygous variant carrying the identical frameshift variant and a large deletion (c.867_∗343+1207del; p.?) starting in exon 5. Both individuals had clinical features of PCD but normal ciliary axoneme structure. In this research, using human nasal cells, mouse models, and X.laevis embryos, we show that GAS2L2 is abundant at the apical surface of ciliated cells, where it localizes with basal bodies, basal feet, rootlets, and actin filaments. Cultured GAS2L2-deficient nasal epithelial cells from one of the affected individuals showed defects in ciliary orientation and had an asynchronous and hyperkinetic (GAS2L2-deficient = 19.8 Hz versus control = 15.8 Hz) ciliary-beat pattern. These results were recapitulated in Gas2l2-/- mouse tracheal epithelial cell (mTEC) cultures and in X. laevis embryos treated with Gas2l2 morpholinos. In mice, the absence of Gas2l2 caused neonatal death, and the conditional deletion of Gas2l2 impaired mucociliary clearance (MCC) and led to mucus accumulation. These results show that a pathogenic variant in GAS2L2 causes a genetic defect in ciliary orientation and impairs MCC and results in PCD.


Subject(s)
Cilia/pathology , Ciliary Motility Disorders/genetics , Ciliary Motility Disorders/physiopathology , Microfilament Proteins/deficiency , Microtubule-Associated Proteins/deficiency , Xenopus Proteins/deficiency , Animals , Ciliary Motility Disorders/pathology , Disease Models, Animal , Exons/genetics , Female , Gene Deletion , Genes, Lethal , Humans , Male , Mice , Mice, Knockout , Microfilament Proteins/genetics , Microtubule-Associated Proteins/genetics , Phenotype , Rotation , Xenopus/embryology , Xenopus/genetics , Xenopus Proteins/genetics
15.
J Aerosol Med Pulm Drug Deliv ; 32(1): 47-53, 2019 02.
Article in English | MEDLINE | ID: mdl-30376396

ABSTRACT

BACKGROUND: Electronic cigarettes (ECIGs) are widely used, but their health effects are not well known. ECIG exposure is difficult to quantify, and a direct measurement of deposition would be beneficial to in vivo and in vitro toxicity studies. The aim of this study was to demonstrate effective radiolabeling of an ECIG. METHODS: A technetium-99m-labeled carbon ultrafine (TCU) aerosol was generated and introduced to a fourth-generation ECIG before nucleation and aerosol formation. The aerosolized e-liquid was a commercially available strawberry flavor containing 1.2% nicotine in a 55% propylene glycol and 45% vegetable glycerine base. An ECIG power setting of 100 W was selected. Mass and radioactivity were measured on each stage within a Sierra Cascade Impactor at 14 L/min to verify the labeling technique using the calculated aerodynamic diameters. A strong positive correlation (R2 > 0.95) between the percent activity and percent mass deposition on each stage provides a reliable validation of colocation. RESULTS: Unlabeled ECIG aerosol from the chosen e-liquid produced a mass median aerodynamic diameter (MMAD) of 0.85 µm. An ECIG labeled with TCU produced an aerosol with an activity median aerodynamic diameter of 0.84 µm and an MMAD of 0.84 µm. The relative mass versus radioactivity on each plate was highly correlated (average R2 = 0.973, p < 0.001). CONCLUSION: A TCU radiolabel was generated and shown to associate with the mass of an aerosol produced by a typical commercially available ECIG. Thus, the radioactivity of the deposited aerosol may be used to determine ECIG aerosol deposition for the future in vivo and in vitro dosimetry studies of the third- and fourth-generation ECIGs.


Subject(s)
Carbon/chemistry , Electronic Nicotine Delivery Systems , Nicotine/chemistry , Nicotinic Agonists/chemistry , Technetium/chemistry , Vaping , Administration, Inhalation , Aerosols , Carbon/administration & dosage , Nicotine/administration & dosage , Nicotinic Agonists/administration & dosage , Particle Size , Particulate Matter , Technetium/administration & dosage
16.
JCI Insight ; 3(24)2018 12 20.
Article in English | MEDLINE | ID: mdl-30568035

ABSTRACT

BACKGROUND: The ability to restore cystic fibrosis transmembrane regulator (CFTR) function with effective small molecule modulators in patients with cystic fibrosis provides an opportunity to study relationships between CFTR ion channel function, organ level physiology, and clinical outcomes. METHODS: We performed a multisite, prospective, observational study of ivacaftor, prescribed in patients with the G551D-CFTR mutation. Measurements of lung mucociliary clearance (MCC) were performed before and after treatment initiation (1 and 3 months), in parallel with clinical outcome measures. RESULTS: Marked acceleration in whole lung, central lung, and peripheral lung MCC was observed 1 month after beginning ivacaftor and was sustained at 3 months. Improvements in MCC correlated with improvements in forced expiratory volume in the first second (FEV1) but not sweat chloride or symptom scores. CONCLUSIONS: Restoration of CFTR activity with ivacaftor led to significant improvements in MCC. This physiologic assessment provides a means to characterize future CFTR modulator therapies and may help to predict improvements in lung function. TRIAL REGISTRATION: ClinicialTrials.gov, NCT01521338. FUNDING: CFF Therapeutics (GOAL11K1).


Subject(s)
Aminophenols/therapeutic use , Cystic Fibrosis/drug therapy , Mucociliary Clearance/drug effects , Quinolones/therapeutic use , Adolescent , Adult , Child , Cystic Fibrosis/metabolism , Cystic Fibrosis Transmembrane Conductance Regulator/metabolism , Female , Forced Expiratory Volume , Humans , Longitudinal Studies , Male , Mutation , Prospective Studies , Respiratory Function Tests , Treatment Outcome , Young Adult
17.
J Cyst Fibros ; 17(5): 650-656, 2018 09.
Article in English | MEDLINE | ID: mdl-29371133

ABSTRACT

BACKGROUND: Inhaled hypertonic saline (HS) has been shown to increase mucociliary clearance (MCC) and improve clinical outcomes in adults and adolescents with cystic fibrosis (CF). However, in younger children with CF, a large study failed to demonstrate clinical benefits. This discrepancy could reflect pharmacodynamic differences in the MCC response to HS in different populations. We previously demonstrated the absence of a sustained effect of HS on MCC in healthy adults and in this study sought to characterize the durability of the MCC response to HS in adults with CF. METHODS: At two study sites, MCC was measured in CF adults using gamma scintigraphy during three separate visits: at baseline, 15 min, and 4 h after a single dose of HS (7% NaCl, 4 mL). Particle clearance rates at these visits were used to assess the durability of the MCC response to HS. RESULTS: The average 90-minute clearance rate measured 4 h after HS was significantly increased (21.81% ±â€¯12.8) when compared to baseline (13.77% ±â€¯8.7, p = .048) and showed no apparent slowing relative to the rate measured 15 min after HS. While not all subjects responded to HS, the acute response strongly predicted the sustained effect in these subjects (r = 0.896, p < .0001). CONCLUSIONS: These results suggest that, in contrast to healthy adults, a single dose of HS has a prolonged effect on MCC in adults with CF, which lasts at least 4 h. This may explain its clinical efficacy in this population.


Subject(s)
Cystic Fibrosis/drug therapy , Mucociliary Clearance/drug effects , Saline Solution, Hypertonic/administration & dosage , Administration, Inhalation , Adolescent , Adult , Cross-Over Studies , Cystic Fibrosis/diagnostic imaging , Female , Humans , Male , Middle Aged , Radionuclide Imaging
18.
J Aerosol Med Pulm Drug Deliv ; 31(4): 204-211, 2018 08.
Article in English | MEDLINE | ID: mdl-29035122

ABSTRACT

BACKGROUND: Using planar gamma scintigraphy of inhaled radioaerosols, we have developed new analytical methods for assessing homogeneity of aerosol deposition and time-dependent particle clearance on a pixel-by-pixel basis, and applied them to a therapeutic cystic fibrosis (CF) study. METHODS: At baseline and 1 month after beginning treatment with ivacaftor, a cystic fibrosis transmembrane regulator modulator for CF patients with at least one copy of the G551D mutation (n = 13), initial deposition and subsequent mucociliary clearance (MCC) of radiolabeled particles (99mTechnetium-sulfur colloid, 5 µm mass median aerodynamic diameter) inhaled under controlled breathing conditions were measured. RESULTS: Improved homogeneity of deposition, that is, decreased areas of higher and lower particle deposition in the lungs, was observed following ivacaftor treatment. The mean number ratio (NR) of pixels with higher deposition, relative to lung size, decreased from 0.14 to 0.09 (p = 0.003) and mean NR of colder pixels decreased from 0.23 to 0.19 (p = 0.004). Particle clearance was also improved following treatment, with mean MCC through 60 minutes equal to 12% versus 24%, without and with treatment, respectively (p = 0.010). Pixel-level analysis of MCC showed that (1) the fraction of pixels clearing >30% at 60 minutes was increased from 0.13 to 0.32 (p = 0.007); and (2) the fraction of pixels clearing <5% at 60 minutes was decreased from 0.54 to 0.37 (p = 0.014), indicating an overall recruitment of more fast-clearing lung regions with ivacaftor treatment. CONCLUSION: These detailed pixel analyses of deposition and clearance homogeneity may supplement traditional methods that use large regions of interest for assessing efficacy and mechanisms of therapeutic intervention in patients with airways disease.


Subject(s)
Aminophenols/administration & dosage , Cystic Fibrosis/drug therapy , Mucociliary Clearance , Quinolones/administration & dosage , Administration, Inhalation , Adolescent , Adult , Aerosols , Cystic Fibrosis/metabolism , Cystic Fibrosis Transmembrane Conductance Regulator/genetics , Female , Humans , Male , Young Adult
19.
J Aerosol Med Pulm Drug Deliv ; 30(5): 322-331, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28277885

ABSTRACT

BACKGROUND: To quantify the relationship between regional lung ventilation and coarse aerosol deposition in the supine healthy human lung, we used oxygen-enhanced magnetic resonance imaging and planar gamma scintigraphy in seven subjects. METHODS: Regional ventilation was measured in the supine posture in a 15 mm sagittal slice of the right lung. Deposition was measured by using planar gamma scintigraphy (coronal scans, 40 cm FOV) immediately postdeposition, 1 hour 30 minutes and 22 hours after deposition of 99mTc-labeled particles (4.9 µm MMAD, GSD 2.5), inhaled in the supine posture (flow 0.5 L/s, 15 breaths/min). The distribution of retained particles at different times was used to infer deposition in different airway regions, with 22 hours representing alveolar deposition. The fraction of total slice ventilation per quartile of lung height from the lung apex to the dome of the diaphragm at functional residual capacity was computed, and co-registered with deposition data-apices aligned-using a transmission scan as reference. The ratio of fractional alveolar deposition to fractional ventilation of each quartile (r) was used to evaluate ventilation and deposition matching (r > 1, regional aerosol deposition fraction larger than regional ventilation fraction). RESULTS: r was not significantly different from 1 for all regions (1.04 ± 0.25, 1.08 ± 0.22, 1.03 ± 0.17, 0.92 ± 0.13, apex to diaphragm, p > 0.40) at the alveolar level (r22h). For retention times r0h and r1h30, only the diaphragmatic region at r1h30 differed significantly from 1. CONCLUSIONS: These results support the hypothesis that alveolar deposition is directly proportional to ventilation for ∼5 µm particles that are inhaled in the supine posture and are consistent with previous simulation predictions that show that convective flow is the main determinant of aerosol transport to the lung periphery.


Subject(s)
Pulmonary Alveoli/metabolism , Pulmonary Ventilation/physiology , Supine Position , Technetium Tc 99m Sulfur Colloid/administration & dosage , Administration, Inhalation , Adult , Aerosols , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Radionuclide Imaging/methods , Respiration , Technetium Tc 99m Sulfur Colloid/pharmacokinetics , Tidal Volume , Time Factors
20.
J Aerosol Med Pulm Drug Deliv ; 30(4): 223-229, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28157412

ABSTRACT

BACKGROUND: Efficient delivery of aerosols to the lungs via the nasal route has been difficult to achieve, but it may offer benefits over the traditional oral route for a range of patient populations. Because slow, continuous delivery of short-acting agents could improve safety, tolerability, compliance, and efficacy when compared with the rapid, intermittent aerosol treatments delivered by mouthpiece or mask, a novel trans-nasal pulmonary aerosol delivery (tPAD) device was developed. The tPAD incorporates an aerosol particle-size selection chamber and a custom nasal cannula that are specifically optimized for aerosol delivery to the lung via the nasal route. The tPAD device produced a steady aerosol output (∼2 mL/h) from an optimized nasal cannula with negligible rainout in the cannula for up to 8 hours. The generated aerosol particles were small enough to minimize nasal deposition [volume median diameter (VMD) = 1.4 µm]. METHODS: In this proof-of-concept study, gamma scintigraphy was used to quantitate deposition efficiency of 99mTc-labeled DTPA in 7% NaCl (hypertonic saline) in healthy human subjects (n = 6) during a short dosing period (15 minutes). A comparison was made with a standard oral jet nebulizer in the same subjects. RESULTS: The tPAD device achieved high pulmonary deposition (39% ± 8%), based on emitted dose, and matched that of the oral jet nebulizer (36% ± 9%). Low fractions of aerosol deposition in the head and nose region were observed for tPAD (6% ± 6%) and jet nebulizer deliver (1% ± 1%) as well. CONCLUSIONS: A profile of high pulmonary deposition efficiency and low nasal dose may enable the sustained use of the tPAD platform with a variety of therapeutic agents for a range of pulmonary disorders.


Subject(s)
Drug Delivery Systems , Lung/metabolism , Nebulizers and Vaporizers , Technetium Tc 99m Pentetate/administration & dosage , Administration, Inhalation , Administration, Intranasal , Adult , Aerosols/administration & dosage , Cannula , Cross-Over Studies , Equipment Design , Humans , Masks , Particle Size , Radiopharmaceuticals/administration & dosage , Radiopharmaceuticals/pharmacokinetics , Saline Solution, Hypertonic/administration & dosage , Technetium Tc 99m Pentetate/pharmacokinetics , Tissue Distribution
SELECTION OF CITATIONS
SEARCH DETAIL
...