Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Comput Assist Surg (Abingdon) ; 27(1): 27-34, 2022 12.
Article in English | MEDLINE | ID: mdl-35559720

ABSTRACT

The goal of this study was to assess and compare the precision and accuracy of nine and seven methods usually used in Computer Assisted Orthopedic Surgery (CAOS) to estimate respectively the Knee Center (KC) and the Frontal Plane (FP) for the determination of the HKA angle (HKAA). An in-vitro experiment has been realized on thirteen cadaveric lower limbs. A CAOS software application was developed and allowed the computation of the HKAA according to these nine KC and seven FP methods. The precision and the accuracy of the HKAA measurements were measured. The HKAA precision was highest when the FP is determined using the helical method. The HKAA accuracy was highest using the helical approach to determine the FP and either the notch or the tibial spines to determine the KC. This study shows that the helical approach to determine the FP and either the notch or the middle of tibia spines are the combinations that provide both a good enough accuracy and precision to estimate the HKA.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Surgery, Computer-Assisted , Humans , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Tibia/surgery
2.
Ann Med Surg (Lond) ; 35: 185-188, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30364754

ABSTRACT

INTRODUCTION: We report the case of volar dislocation of the ulnar head occurred after osteosynthesis for the treatment of distal radius fracture. PRESENTATION OF CASE: The patient, 68-year-old female, had the dorsal displaced left distal radius fracture and volar dislocation of the ulnar head. Osteosynthesis was performed using a volar locking plate without postoperative immobilization. Two weeks after surgery, volar dislocation of the ulnar head in distal radioulnar joint (DRUJ) was noted on CT. Re-operation, triangular fibrocartilage complex (TFCC) was sutured to the ulnar fovea using a suture anchor, was performed in order to stabilize DRUJ. At 24 months after surgery, left wrist joint pain and the range of motion have improved, and the Mayo wrist score was excellent. DISCUSSION: Based on the fact that the radius was fractured and the ulna was dislocated in DRUJ at the time of injury, the present case may have been a Galeazzi fracture. CONCLUSION: When distal radius fracture is complicated by ulnar instability of DRUJ, active repair of the TFCC function may be necessary to prevent residual postoperative instability.

3.
Case Rep Orthop ; 2018: 8195376, 2018.
Article in English | MEDLINE | ID: mdl-30034900

ABSTRACT

In this study, we performed osteosynthesis for a distal radius fracture using a minimally invasive approach for a patient with skin disorder of the forearm and obtained favorable results. This case report may provide new findings confirming the usefulness of this surgical approach for distal radius fractures. Blister formation on the right forearm was observed in a 53-year-old female who was diagnosed with a distal fracture of the right radius and underwent splinting in a local hospital, and she was referred to our hospital 2 days after the injury. Minimally invasive locking plate osteosynthesis was performed, and there was no skin lesion at this incision site. Postoperatively, there were no complications in soft tissues and the operative scar was almost unrecognizable. We reported volar locking plate osteosynthesis using the minimally invasive approach in a patient with skin disorder of the forearm. Such patients are rarely encountered. However, this minimally invasive approach is extremely useful for utilizing the advantages of volar locking plate fixation without being affected by the soft tissue environment.

4.
Tech Hand Up Extrem Surg ; 20(2): 71-6, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27015408

ABSTRACT

The management of distal radius fractures has dramatically improved due to the development of a locking plate system. In addition, mini-invasive surgery has been performed in a lot of surgical fields in recent years. The aim of the present study is to investigate the possibility of fixation of a distal radius fracture with a volar locking plate through a 10 mm approach. Eighteen patients with distal radius fracture (mean age: 66 y; range, 28 to 88 y; 8 males and 10 females) were operated on using a volar locking plate. The incision for plating was always 10 mm long. The clinical, cosmetic, and radiologic outcomes were investigated. At 3 months' follow-up, the range of motion of the wrist joint was 67.5 degrees in flexion, 65.6 degrees in extension, 88.3 degrees in pronation, and 88.3 degrees in supination. The % grip strength compared to the healthy side ranged from 35% to 100%. The VAS, Q-DASH, and modified Mayo scores were 0.7, 8.5, and 93.3, respectively (excellent in all 18 patients). Bone union was achieved on plain x-ray radiography and cosmetic problems were satisfied in all patients. Our results suggest that it is possible to achieve fixation of a distal radius fracture with a volar locking plate through a 10 mm approach. However, its applicability to surgery must be carefully examined. If any difficulties in plate installation or approach occur during this intervention, it will be necessary to consider switching to a conventional approach. We believe that surgeons must not adhere to a mini-invasive approach.


Subject(s)
Bone Plates , Fracture Fixation, Internal/methods , Palmar Plate/surgery , Radius Fractures/surgery , Adult , Aged , Aged, 80 and over , Cohort Studies , Female , Humans , Male , Middle Aged , Range of Motion, Articular , Recovery of Function , Treatment Outcome
5.
Eur J Orthop Surg Traumatol ; 25(3): 477-82, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25086617

ABSTRACT

Fracture dislocations of the fifth carpometacarpal are usually treated by percutaneous K-wires despite occasional complications: displacement, stiffness, malunions, and arthritis. Our aims were to evaluate the use of locked K-wire fixation for these fracture dislocations. Our series includes 31 fracture dislocations, five extra-articular and 26 articular, 21 of which were at the base of the metacarpal, four at the hamate, and one involving both the hamate and the metacarpal. Mean tourniquet time was 22 min and irradiation 2 mGy. After reduction, an M4 M5 K-wire and a carpometacarpal wire were connected using an MetaHUS® connector. Immediate immobilization was allowed. Return to normal activity was resumed at 6.5 weeks. At around 15 months follow-up, mean pain score was 8.5, Quick DASH was 6.36, and overall grip strength was 92%, TAM of the fifth ray was 96% of the contralateral side. There were two displacements that were re-operated with good result, three superficial infections, and one case of stiffness. All fractures healed without arthritis. Overall, percutaneous K-wire and splinting of fracture dislocations of the fifth carpometacarpal joint is unstable, and internal fixation can cause adhesions and stiffness. Our results show that the percutaneous locked K-wire technique is a good alternative as it associates closed reduction with K-wire fixation and a solid fixation using an external connector. This technique allows immediate mobilization of the hand and removal of hardware in clinic.


Subject(s)
Bone Wires , Carpometacarpal Joints/injuries , External Fixators , Intra-Articular Fractures/surgery , Joint Dislocations/surgery , Adolescent , Adult , Arthralgia/etiology , Bone Wires/adverse effects , External Fixators/adverse effects , Follow-Up Studies , Hamate Bone/injuries , Hamate Bone/surgery , Hand Strength , Humans , Male , Metacarpal Bones/injuries , Metacarpal Bones/surgery , Middle Aged , Recovery of Function , Reoperation , Retrospective Studies , Young Adult
6.
Hand Surg ; 19(2): 281-6, 2014.
Article in English | MEDLINE | ID: mdl-24875520

ABSTRACT

Several techniques are used for fixation of Bennett's fractures. The aim of this study was to assess a technique of arthroscopic-assisted reduction and percutaneous cannulated screw fixation of Bennett's fractures. Seven patients (mean age 29 years) with three fractures Type I and four fractures Type II according to Gedda were operated under arthroscopic lavage, fluoroscopic screw fixation, and arthroscopic control of the joint reduction. Arthroscopy, showed satisfactory joint reduction in all cases. At 4.5 months, the mean pain score was 1 (0-4), QuickDASH 15 (0-61), and Kapandji score 9 (5-10). Compared to the contralateral side, first web opening was 86% (58-100), key pinch 73% (45-89), grip strength, and 85% (40-100). Four secondary displacements were noted, two of which had a step of more than 1 mm. Our results showed that the use of arthroscopy for percutaneous screw fixation of Bennett's fractures facilitates joint reduction but does not guarantee stability of fixation.


Subject(s)
Carpometacarpal Joints/surgery , Intra-Articular Fractures/surgery , Joint Dislocations/surgery , Metacarpal Bones/surgery , Adult , Arthroscopy , Bone Screws , Fracture Fixation , Humans , Metacarpal Bones/injuries , Retrospective Studies
7.
Hand Surg ; 19(1): 135-8, 2014.
Article in English | MEDLINE | ID: mdl-24641758

ABSTRACT

We report the case of a traumatic amputation by circular saw of the ring and small fingers, associated with middle finger nail matrix loss and tendon, bone and joint exposure. The replantation was not attempted with patient's consent. Since the nail unit from the ring finger was intact, we decided to harvest the ring finger nail unit for major finger reconstruction. Although the principle of vascularized transfer from a severely damaged finger is widely recognized and the vascularized nail transfer from toe is a relatively common procedure, there is no description of a vascularized nail transfer from a non-replantable digit in the literature.


Subject(s)
Amputation, Traumatic/surgery , Finger Injuries/surgery , Nails/transplantation , Anastomosis, Surgical/methods , Humans , Male , Middle Aged , Nails/blood supply , Plastic Surgery Procedures
8.
Tech Hand Up Extrem Surg ; 18(2): 77-81, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24621457

ABSTRACT

The treatment of choice for first metacarpal base fractures is surgical. Open fixation is stable but causes tendinous adhesions. Percutaneous fixation is minimally invasive but is often followed by secondary displacement. Herein, we describe an alternative approach that combines advantages of both techniques through increasing stability of the Iselin technique by externally connecting the K-wires. Our series included 13 men of mean age 28 years. There were 13 fractures, 6 of which were extra-articular; there were 7 Bennett fractures, 5 of which had a large fracture fragment. After reduction, two 18 mm K-wires were driven medially crossing the 3 cortices of the first and second metacarpals. After bending them at 90-degree angles, the K-wires were connected externally in a construction allowing adaptation of the gap between the K-wires. Gentle immediate mobilization was allowed and the K-wires were removed 6 weeks later in clinic. At 16-month follow-up, mean pain score was 0.2/10 and Quick DASH was 2.9/100. Pinch grip was 81.8% of the contralateral side and grip strength 91.2%. The first web space opening was 79.1%. There was 1 secondary displacement with a good final result and 2 malunions. No arthritis was noted, but the follow-up was short. Our results show that the Iselin technique using locked K-wires is minimally invasive, stable, allows immediate mobilization, and K-wire removal in the office. Its indications may be extended to all fractures of the base of the first metacarpal whether articular or extra-articular.


Subject(s)
Finger Injuries/surgery , Fracture Fixation/methods , Fractures, Bone/surgery , Metacarpal Bones/surgery , Thumb/surgery , Adolescent , Adult , Bone Wires , Humans , Male , Metacarpal Bones/injuries , Middle Aged , Retrospective Studies , Thumb/injuries , Young Adult
9.
Eur J Orthop Surg Traumatol ; 24(6): 877-90, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24258689

ABSTRACT

The volar Henry approach is becoming the gold standard for distal radius fracture fixation. It decreases the incidence of nonunion, limits complications especially complex regional pain syndrome (CRPS) type I, and allows early mobilization of the wrist. Nonetheless, it has some disadvantages such as the size of the incision, which is not esthetically pleasing, and the loss of ligamentotaxis. This is why some authors have developed a mini-invasive approach. The aim of this work was to evaluate the feasibility of the anterior mini-invasive approach of 15 mm in a clinical series of 144 cases of distal radius fracture. All patients were operated under regional anesthesia using the same techniques by five surgeons of the same team. According to the AO classification, there were 83 type A fractures, 2 type B, and 59 type C. A volar plate (Step One(®), Newclip Technics™, Haute-Goulaine, France) was used in all cases. The 2 proximal metaphyseal screws and the 2 distal central epiphyseal screws were monoaxial locking. The 2 distal ulnar and radial epiphyseal screws were placed in polyaxial locking at 20° angulation maximum. Skin closure without drainage was performed. No postoperative immobilization was prescribed, and patients were encouraged to use their upper limb immediately postoperative. No postoperative physiotherapy was prescribed. The mean follow-up was 4.1 months. The final size of the incision was on average 16.1 mm. Mean pain score was 1.8. The Quick DASH score was average 25. Average range of motion was more than 85 %, and global force of the hand was 67 % compared with contralateral side. On X-ray, the mean radial slope was 22°, the mean radial tilt was 8.3°, and the mean radioulnar variance/index was -0.4 mm. There were nine cases of CRPS type I, which all resolved. Specific complications included two secondary displacements and nine tenosynovitis cases. No tendon rupture was noted. Two intra-articular distal radioulnar joint screws had to be removed at 3 months. One epiphyseal screw required removal 1 month postoperative due to loosening. There were no intra-articular radiocarpal screws. Distal radius fracture fixation using a mini-invasive approach is a reliable and reproducible procedure with few complications. It allows anatomical reduction in the distal radius fractures including intra-articular ones. It can be associated with arthroscopy, scaphoid screw fixation or even percutaneous pinning. Thus, most traumatic lesions of the wrist bony or soft tissue can be treated through this mini-invasive approach.


Subject(s)
Fracture Fixation, Internal/methods , Radius Fractures/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Bone Plates , Bone Screws , Feasibility Studies , Female , Follow-Up Studies , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/instrumentation , Hand Strength , Humans , Joint Dislocations/etiology , Male , Middle Aged , Minimally Invasive Surgical Procedures/adverse effects , Minimally Invasive Surgical Procedures/instrumentation , Minimally Invasive Surgical Procedures/methods , Pain, Postoperative/etiology , Radiography , Radius Fractures/diagnostic imaging , Range of Motion, Articular , Reflex Sympathetic Dystrophy/etiology , Tenosynovitis/etiology , Wrist Joint/physiopathology , Young Adult
10.
J Plast Reconstr Aesthet Surg ; 66(11): 1616-8, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23602271

ABSTRACT

UNLABELLED: We report a case of a Type Vb flexor digitorum profundus tendon avulsion in a patient for whom surgery was contraindicated because of a high risk of stroke if anticoagulant treatment was to be stopped. After a 6-week conservative treatment and a 3-week self-physiotherapy programme, the patient achieved a nearly full active range of motion and an excellent functional result. A radiograph demonstrated a good fracture healing. LEVEL OF EVIDENCE: V.


Subject(s)
Finger Injuries/therapy , Tendon Injuries/physiopathology , Tendon Injuries/therapy , Female , Finger Injuries/rehabilitation , Hand Strength , Humans , Middle Aged , Range of Motion, Articular , Recovery of Function , Splints
11.
Eur J Orthop Surg Traumatol ; 23(2): 149-53, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23412445

ABSTRACT

INTRODUCTION: Compared with the other French regions, the incidence of neural tube defects is raised in Brittany. It can be explained by the Celtic origin of the Britton people, who migrated from Great Britain in the High Middle Ages. Notwithstanding, there are no historical or archeological evidences of the occurrence of these pathological conditions in medieval Brittany. MATERIALS AND METHODS: We investigated the incidence of lumbo-sacral malformations on the skeletal remains of 30 individuals excavated from the necropolis of Saint-Urnel (southwest Brittany). RESULTS: We found out several anatomical variations among five specimens, three of which had spinal dysraphism involving the sacrum. CONCLUSION: Our results enrich the very few paleopathological data about spinal dysraphism, from the Hippocratic Corpus to the first description of Spina Bifida in sixteenth century. But, their interpretation remains delicate until the same genetic factors are shown in the etiology of both open and closed spinal dysraphism.


Subject(s)
Spina Bifida Occulta/history , Spinal Dysraphism/history , Adult , France/epidemiology , History, Medieval , Humans , Lumbar Vertebrae/abnormalities , Lumbar Vertebrae/pathology , Lumbosacral Region/abnormalities , Lumbosacral Region/pathology , Skeleton , Spina Bifida Occulta/pathology , Spinal Dysraphism/pathology
12.
Surg Radiol Anat ; 35(3): 225-31, 2013 Apr.
Article in English | MEDLINE | ID: mdl-22941267

ABSTRACT

BACKGROUND: The dorsal approach to the wrist is the exposure of choice for most of the surgical procedures on the radiocarpal and intercarpal joints. Contrary to the volar approach, it encounters neither the main arteries nor the motor nerve branch. However, the dorsal approach goes necessarily through the extensor retinaculum. We describe two transseptal dorsal approaches that pass through the extensor retinaculum in the thickness of a septum between two compartments. A virtual space was developed beneath the infratendinous retinaculum (which is a deep layer covering the floor of the extensor compartments) to expose the periosteum, the ligaments and the joint capsule without opening the extensor compartments. METHODS: Twenty cadaveric wrists have been dissected to study the feasibility of the two transseptal approaches. Ten wrists were exposed through a 3-4 transseptal approach, passing through the extensor retinaculum in the thickness of the septum between the third and fourth compartments. Ten wrists were exposed through a 4-5 transseptal approach, passing through the extensor retinaculum in the thickness of the septum between the fourth and fifth compartments. The extent of violations of extensor compartments and joint capsule, and the exposed anatomical structures were noted. At the end of each dissection, the whole extensor system was outrightly removed for histological study. RESULTS: The feasibility of the transseptal approaches was demonstrated for all the dissected wrists. The dissection plane beneath the infratendinous retinaculum was macroscopically and microscopically highlighted. CONCLUSIONS: The transseptal approaches provide a good exposure to the dorsal side of the wrist joint, without opening the extensor tendon compartments.


Subject(s)
Wrist Joint/surgery , Wrist/surgery , Humans , Wrist/anatomy & histology , Wrist Joint/anatomy & histology
13.
J Wrist Surg ; 2(4): 294-8, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24436832

ABSTRACT

PURPOSE: In video surgery, and more specifically in arthroscopy, one of the major problems is positioning the camera and instruments within the anatomic environment. The concept of computer-guided video surgery has already been used in ear, nose, and throat (ENT), gynecology, and even in hip arthroscopy. These systems, however, rely on optical or mechanical sensors, which turn out to be restricting and cumbersome. The aim of our study was to develop and evaluate the accuracy of a navigation system based on electromagnetic sensors in video surgery. METHODS: We used an electromagnetic localization device (Aurora, Northern Digital Inc., Ontario, Canada) to track the movements in space of both the camera and the instruments. We have developed a dedicated application in the Python language, using the VTK library for the graphic display and the OpenCV library for camera calibration. RESULTS: A prototype has been designed and evaluated for wrist arthroscopy. It allows display of the theoretical position of instruments onto the arthroscopic view with useful accuracy. DISCUSSION: The augmented reality view represents valuable assistance when surgeons want to position the arthroscope or locate their instruments. It makes the maneuver more intuitive, increases comfort, saves time, and enhances concentration.

14.
Surg Radiol Anat ; 32(2): 129-33, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19779661

ABSTRACT

BACKGROUND: Following the example of the anterior cruciate ligament reconstruction, the success of meniscus allograft transplantation relies on good position of the graft and firm anchorage. The anatomy of the intercondylar region and the connections between the cruciate ligament and the meniscal horns have been the subject of many surveys. However, as far as we know, there is only one description of meniscoligamentous band between the posterior horn of the lateral meniscus (PHLM) and the anterior cruciate ligament (ACL) (Lahlaïdi in Rev Chir Orthop Reparatrice Appar Mot 57(8):593-600, 1971). METHODS: Fourteen cadaveric knees have been dissected to study the presence and variations of the band between the PHLM and the ACL. In addition, we undertook a histological study to ensure its ligamentous nature. RESULTS: This meniscoligamentous band was found 13 times amongst the 14 investigated knees, and its ligamentous intra-articular extra-synovial nature was proved. CONCLUSIONS: This study helps us to better understand the biomechanics of the menisci that are both stable and mobile structures.


Subject(s)
Anterior Cruciate Ligament/anatomy & histology , Menisci, Tibial/anatomy & histology , Arthroscopy , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...