Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Biol Reprod ; 110(3): 476-489, 2024 Mar 13.
Article in English | MEDLINE | ID: mdl-38091979

ABSTRACT

Recurrent spontaneous abortion, defined as at least three unexplained abortions occurring before the 20-24 week of pregnancy, has a great impact on women's quality of life. Ephrin receptor B4 has been associated with trophoblast function in preeclampsia. The present study aimed to verify the hypothesis that ephrin receptor B4 regulates the biological functions of trophoblasts in recurrent spontaneous abortion and to explore the upstream mechanism. Ephrin receptor B4 was overexpressed in mice with recurrent spontaneous abortion. Moreover, ephrin receptor B4 inhibited trophoblast proliferation, migration, and invasion while promoting apoptosis. Downregulation of early growth response protein 1 expression in mice with recurrent spontaneous abortion led to ephrin receptor B4 overexpression. Poor expression of WT1-associated protein in mice with recurrent spontaneous abortion reduced the modification of early growth response protein 1 mRNA methylation, resulting in decreased early growth response protein 1 mRNA stability and expression. Overexpression of WT1-associated protein reduced the incidence of recurrent spontaneous abortion in mice by controlling the phenotype of trophoblasts, which was reversed by early growth response protein 1 knockdown. All in all, our findings demonstrate that dysregulation of WT1-associated protein contributes to the instability of early growth response protein 1, thereby activating ephrin receptor B4-induced trophoblast dysfunction in recurrent spontaneous abortion. Our study provides novel insights into understanding the molecular pathogenesis of recurrent spontaneous abortion.


Subject(s)
Abortion, Habitual , Abortion, Spontaneous , Animals , Female , Humans , Mice , Pregnancy , Abortion, Habitual/metabolism , Abortion, Spontaneous/genetics , Cell Movement , Cell Proliferation , Early Growth Response Protein 1 , Ephrins/metabolism , Quality of Life , Trophoblasts/metabolism
2.
J Orthop Surg Res ; 17(1): 312, 2022 Jun 11.
Article in English | MEDLINE | ID: mdl-35690864

ABSTRACT

BACKGROUND: Minimally invasive surgery for pelvic fracture using anterior ring internal fixator system is increasing gradually, and the way to insert the fixation screws in the fixation system is the key technical points of the method. However, there have been few studies on insertion of fixation screws for the anterior pelvic ring internal fixator system. OBJECTIVE: To identify safe channels for fixation screws in the anterior pelvic fixator system and provide the anatomical basis for insertion of fixation screws in clinical operation. METHODS: Screw insertion was simulated into a total of 40 pelvic finite element models as well as 16 fresh pelvic specimens, and the channel parameters were measured. RESULTS: Finite elements (male, female) include: screws in ilium: length 114.4 ± 4.1 and 107.6 ± 8.3 mm, respectively; diameter 11.7 ± 0.5 and 10.0 ± 0.6 mm, distance between screw and anterior inferior iliac spine: 5.5 ± 1.0 and 5.6 ± 1.0 mm, angle of coronal plane 55.8° ± 2.4° and 50.6° ± 3.1°, angle of sagittal plane 26.6° ± 1.0° and 24.5° ± 1.9° and angle of horizontal plane 64.9 ± 3.7 and 58.1 ± 3.1; screws in pubis: length 47.0 ± 2.0 and 39.8 ± 3.9 mm, diameter 7.1 ± 0.4 and 6.1 ± 0.4 mm. Specimens (male, female) include: distance between screw and anterior inferior iliac spine: 5.5 ± 0.5 and 5.6 ± 0.7 mm, angle of coronal plane 55.9° ± 1.3° and 50.7° ± 1.5°, angle of sagittal plane 26.7° ± 0.5° and 24.1° ± 0.9° and angle of horizontal plane 64.8° ± 0.6° and 58.8° ± 0.8°. In the comparison between female and male in each group, differences in distances between screws and anterior inferior iliac spine and median line of symphysis pubis (P > 0.05) were not statistically significant; differences in the remaining parameters were statistically significant (P < 0.05). CONCLUSIONS: If surgeons paid attention to sex differences, select screws of appropriate diameter and length and hold the insertion position and direction, screws in the anterior pelvic ring fixation system could be safely inserted.


Subject(s)
Fractures, Bone , Pelvic Bones , Bone Screws/adverse effects , Female , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Humans , Ilium/surgery , Male , Pelvic Bones/surgery , Pelvis
3.
J Orthop Surg Res ; 16(1): 715, 2021 Dec 14.
Article in English | MEDLINE | ID: mdl-34906168

ABSTRACT

BACKGROUND: How to perform minimally invasive surgery for Tile C pelvic fracture is a major problem in clinical practice. We performed minimally invasive surgery for Tile C pelvic fracture using anterior ring internal fixator systems combined with sacroiliac screw fixation. OBJECTIVE: To investigate the advantages and efficacy of anterior ring internal fixator systems combined with sacroiliac screw fixation in the treatment of Tile C pelvic fracture. METHODS: From May 2017 to May 2020, 27 patients with Tile C pelvic fracture who underwent anterior ring internal fixator system combined with sacroiliac screw fixation (group A) and 21 patients with Tile C pelvic fracture who underwent plate-screw system combined with sacroiliac screw fixation (group B) were retrospectively analyzed. RESULTS: All 48 patients were followed up for more than 12 months, all fractures healed within 3-6 months. The operative time, intraoperative bleeding volume, blood transfusion volume, incision length, hospital stay, complication rate and Majeed score were 63.5 ± 10.7 min, 48.3 ± 27.9 ml, 0 ml, 4.5 ± 0.8 cm, 10.2 ± 2.7 d, 3.7% and 89.7 ± 4.6 points, respectively, in group A and 114.8 ± 19.1 min, 375 ± 315.8 ml, 266.7 ± 326.6 ml, 9.2 ± 3.9 cm, 20.9 ± 5.7 d, 23.8% and 88.7 ± 4.9 points, respectively, in group B. Combined excellent and good rates of the Matta evaluation and Majeed score were 100% in both groups. There were no significant differences in the Matta evaluation or Majeed score between the two groups (both P > 0.05), whereas the operative time, intraoperative bleeding volume, blood transfusion volume, incision length and hospital stay were significantly less in group A (all P < 0.05). CONCLUSION: An anterior ring internal fixator system combined with sacroiliac screw fixation can effectively treat Tile C pelvic fracture, and has advantages, including minimal invasiveness, simple operation, short operative time, safe and reliable features, fewer complications, short hospital stay and a good curative effect.


Subject(s)
Bone Screws , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Internal Fixators , Pelvic Bones/injuries , Adult , Aged , Female , Fracture Fixation, Internal/instrumentation , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome
4.
J Orthop Surg Res ; 16(1): 225, 2021 Mar 27.
Article in English | MEDLINE | ID: mdl-33773576

ABSTRACT

BACKGROUND: How to perform minimally-invasive surgery on Tile C pelvic fractures is very difficult, and it is also a hot topic in orthopedic trauma research. We applied minimally-invasive treatment using an anterior internal fixator combined with sacroiliac screws. OBJECTIVES: To compare the biomechanical properties of different fixation models in pelvic facture specimens, using an internal fixation system or a steel plate combined with sacroiliac screws. METHODS: Sixteen fresh adult cadaver pelvic specimens were randomly separated into four groups named A, B, C, and D. The four groups were respectively stabilized using a two-screwed, three-screwed, or four-screwed anterior internal fixator or a steel plate with sacroiliac screws. All models were tested in both standing and sitting positions. Vertical loads of 600 N were applied increasingly. Shifts of bilateral sacroiliac joints and pubis rupture were measured. RESULTS: The shifts in sacroiliac joints and pubis rupture in the standing position were all less than 3.5 mm, and the shifts in the sitting position were all less than 1 mm. In the standing position, the results of shifts in the sacroiliac joints were group C < group D < group B < group A. For comparisons between A:B and C:D, P > 0.05. For comparisons between A, B:C, and D, P < 0.05. The results of shifts in pubis ruptures were group D < group C < group B < group A. In the comparison between C:D, P > 0.05; for comparisons between A:B, A:C, A:D, B:C, and B:D, P < 0.05. In the sitting posture, the results of shifts in the sacroiliac joints were group C < group D < group B < group A, and the shifts in the pubis ruptures were group D < group C < roup B < group A. For comparison between C:D, P > 0.05. For comparisons between A:B, A:C, A:D, B:C, and B:D, P < 0.05. CONCLUSION: Use of an anterior internal fixator combined with sacroiliac screws effectively stabilized Tile C3 pelvic fractures. The stability of specimens increased as the number of screws in the internal fixator increased.


Subject(s)
Bone Screws , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Minimally Invasive Surgical Procedures/methods , Pelvic Bones/surgery , Sacroiliac Joint/surgery , Adult , Biomechanical Phenomena , Bone Plates , Cadaver , Humans , Posture/physiology , Pubic Bone/surgery
5.
Med Sci Monit ; 26: e915886, 2020 Mar 12.
Article in English | MEDLINE | ID: mdl-32163378

ABSTRACT

BACKGROUND Despite the development of minimally invasive techniques for pelvic fractures, performing minimally invasive surgery for Tile C3 pelvic fractures remains challenging. Thus, we propose use of anterior ring internal fixation combined with sacroiliac screw fixation for Tile C3 pelvic fractures. MATERIAL AND METHODS A normal pelvic finite element model (model 1) was established. Two-screw, three-screw, and four-screw anterior ring internal fixators and plate combined with sacroiliac screw Tile C3 pelvic fracture models (models 2, 3, 4, and 5, respectively) were also established. A vertical load of 600 N was applied on S1. The distribution of displacement and stress in the standing and sitting positions was compared. RESULTS Models 2, 3, 4, and 5 can provide effective fixation. Compared with model 1, in the erect position, the maximum displacement of models 2, 3, 4, and 5 increased by 66.51%, 65.36%, 35.16%, and 35.47% and the maximum stress increased by 201.78%, 130.65%, 100.82%, and 99.03%, respectively. Compared with model 1, in sitting position, the maximum displacement of models 2, 3, 4, and 5 increased by 9.1%, 11.04%, 5.57%, and 8.59% and the maximum stress increased by 157.73%, 118.02%, 98.32%, and 93.16%, respectively. CONCLUSIONS Anterior ring internal fixators combined with sacroiliac screws can effectively fix Tile C3 pelvic fractures.


Subject(s)
Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Models, Biological , Pelvic Bones/injuries , Sacroiliac Joint/surgery , Adult , Biomechanical Phenomena , Bone Plates , Bone Screws , Finite Element Analysis , Fracture Fixation, Internal/instrumentation , Humans , Male , Pelvic Bones/diagnostic imaging , Pelvic Bones/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...