Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
2.
Insights Imaging ; 15(1): 44, 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38353807

ABSTRACT

OBJECTIVES: To develop and compare noninvasive models for differentiating between combined hepatocellular-cholangiocarcinoma (cHCC-CCA) and HCC based on serum tumor markers, contrast-enhanced ultrasound (CEUS), and computed tomography (CECT). METHODS: From January 2010 to December 2021, patients with pathologically confirmed cHCC-CCA or HCC who underwent both preoperative CEUS and CECT were retrospectively enrolled. Propensity scores were calculated to match cHCC-CCA and HCC patients with a near-neighbor ratio of 1:2. Two predicted models, a CEUS-predominant (CEUS features plus tumor markers) and a CECT-predominant model (CECT features plus tumor markers), were constructed using logistic regression analyses. Model performance was evaluated by the area under the curve (AUC), sensitivity, specificity, and accuracy. RESULTS: A total of 135 patients (mean age, 51.3 years ± 10.9; 122 men) with 135 tumors (45 cHCC-CCA and 90 HCC) were included. By logistic regression analysis, unclear boundary in the intratumoral nonenhanced area, partial washout on CEUS, CA 19-9 > 100 U/mL, lack of cirrhosis, incomplete tumor capsule, and nonrim arterial phase hyperenhancement (APHE) volume < 50% on CECT were independent factors for a diagnosis of cHCC-CCA. The CECT-predominant model showed almost perfect sensitivity for cHCC-CCA, unlike the CEUS-predominant model (93.3% vs. 55.6%, p < 0.001). The CEUS-predominant model showed higher diagnostic specificity than the CECT-predominant model (80.0% vs. 63.3%; p = 0.020), especially in the ≤ 5 cm subgroup (92.0% vs. 70.0%; p = 0.013). CONCLUSIONS: The CECT-predominant model provides higher diagnostic sensitivity than the CEUS-predominant model for CHCC-CCA. Combining CECT features with serum CA 19-9 > 100 U/mL shows excellent sensitivity. CRITICAL RELEVANCE STATEMENT: Combining lack of cirrhosis, incomplete tumor capsule, and nonrim arterial phase hyperenhancement (APHE) volume < 50% on CECT with serum CA 19-9 > 100 U/mL shows excellent sensitivity in differentiating cHCC-CCA from HCC. KEY POINTS: 1. Accurate differentiation between cHCC-CCA and HCC is essential for treatment decisions. 2. The CECT-predominant model provides higher accuracy than the CEUS-predominant model for CHCC-CCA. 3. Combining CECT features and CA 19-9 levels shows a sensitivity of 93.3% in diagnosing cHCC-CCA.

3.
Acta Biomater ; 173: 36-50, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37939816

ABSTRACT

The ablation effect of focused ultrasound (FUS) has played an increasingly important role in the biomedical field over the past decades, and its non-invasive features have great advantages, especially for clinical diseases where surgical treatment is not available or appropriate. Recently, rapid advances in the adjustable morphology, enzyme-mimetic activity, and biostability of sono-activated materials have significantly promoted the medical application of FUS ablation. However, a systematic review of sono-activated materials based on FUS ablation is not yet available. This progress review focuses on the recent design, fundamental principles, and applications of sono-activated materials in the FUS ablation biomedical field. First, the different ablation mechanisms and the key factors affecting ablation are carefully determined. Then, the design of sono-activated materials with high FUS ablation efficiencies is comprehensively discussed. Subsequently, the representative biological applications are summarized in detail. Finally, the primary challenges and future perspectives are also outlined. We believe this timely review will provide key information and insights for further exploration of focused ultrasound ablation and new inspiration for designing future sono-activated materials. STATEMENT OF SIGNIFICANCE: The ablation effect of focused ultrasound (FUS) has played an increasingly important role in the biomedical field over the past decades. However, there are also some challenges of FUS ablation, such as skin burns, tumour recurrence after thermal ablation, and difficulty in controlling cavitation ablation. The rapid advance in adjustable morphology, enzyme-mimetic activity, and biostability of sono-activated materials has significantly promoted the medical application of FUS ablation. However, the systematic review of sono-activated materials based on FUS ablation is not yet available. This progress review focuses on the recent design, fundamental principles, and applications in the FUS ablation biomedical field of sono-activated materials. We believe this timely review will provide key information and insights for further exploration of FUS ablation.


Subject(s)
Hyperthermia, Induced , Neoplasms , Humans
4.
Front Oncol ; 13: 1245686, 2023.
Article in English | MEDLINE | ID: mdl-38023257

ABSTRACT

Objective: This study aimed to develop and validate a nomogram based on ultrasonographic features and clinical indicators to differentiate mass-forming intrahepatic cholangiocarcinoma (MF-ICC) from hepatic metastatic colorectal adenocarcinoma. Materials and methods: A total of 343 patients with pathologically confirmed MF-ICC or metastatic colorectal adenocarcinoma were enrolled between October 2018 and July 2022. Patients were randomly assigned to training and validation sets at a ratio of 7:3. Preoperative ultrasound features and clinical indicators were retrieved. Univariate logistic regression analysis was employed to select relevant features. Multivariate logistic regression analysis was used to establish a predictive model, which was presented as a nomogram in training sets. The model's performance was assessed in terms of discrimination, calibration, and clinical usefulness. Results: The study included 169 patients with MF-ICC and 174 with liver metastatic colorectal adenocarcinoma, assigned to training (n=238) and validation (n=105) cohorts. The nomogram incorporated ultrasound features (tumor size, lesion number, echogenicity, tumor necrosis, and rim arterial phase hyperenhancement) and clinical information (serum levels of CEA, CA19-9, CA125). The nomogram demonstrated promising performance in differentiating these two entities in both training and validation sets, with an AUC value of 0.937 (95%CI: 0.907,0.969) and 0.916 (95%CI: 0.863,0.968), respectively. The Hosmer-Lemeshow test and calibration curves confirmed good consistency between predictions and observations. Additionally, decision curve analysis confirmed the nomogram's high clinical practicability. Conclusion: The nomogram based on ultrasound features and clinical indicators demonstrated good discrimination performance in differentiating MF-ICC from metastatic colorectal adenocarcinoma, which may enhance clinical decision-making process in managing these challenging diagnostic scenarios.

5.
World J Gastroenterol ; 29(17): 2534-2550, 2023 May 07.
Article in English | MEDLINE | ID: mdl-37213404

ABSTRACT

In the world, nonalcoholic fatty liver disease (NAFLD) accounts for majority of diffuse hepatic diseases. Notably, substantial liver fat accumulation can trigger and accelerate hepatic fibrosis, thus contributing to disease progression. Moreover, the presence of NAFLD not only puts adverse influences for liver but is also associated with an increased risk of type 2 diabetes and cardiovascular diseases. Therefore, early detection and quantified measurement of hepatic fat content are of great importance. Liver biopsy is currently the most accurate method for the evaluation of hepatic steatosis. However, liver biopsy has several limitations, namely, its invasiveness, sampling error, high cost and moderate intraobserver and interobserver reproducibility. Recently, various quantitative imaging techniques have been developed for the diagnosis and quantified measurement of hepatic fat content, including ultrasound- or magnetic resonance-based methods. These quantitative imaging techniques can provide objective continuous metrics associated with liver fat content and be recorded for comparison when patients receive check-ups to evaluate changes in liver fat content, which is useful for longitudinal follow-up. In this review, we introduce several imaging techniques and describe their diagnostic performance for the diagnosis and quantified measurement of hepatic fat content.


Subject(s)
Diabetes Mellitus, Type 2 , Non-alcoholic Fatty Liver Disease , Humans , Non-alcoholic Fatty Liver Disease/diagnostic imaging , Non-alcoholic Fatty Liver Disease/pathology , Diabetes Mellitus, Type 2/pathology , Reproducibility of Results , Liver/diagnostic imaging , Liver/pathology , Magnetic Resonance Imaging/methods , Biopsy
6.
Chin Med J (Engl) ; 136(17): 2028-2036, 2023 Sep 05.
Article in English | MEDLINE | ID: mdl-36728948

ABSTRACT

BACKGROUND: Patients with mass-forming pancreatitis (MFP) or pancreatic ductal adenocarcinoma (PDAC) presented similar clinical symptoms, but required different treatment approaches and had different survival outcomes. This meta-analysis aimed to compare the diagnostic performance of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) in differentiating MFP from PDAC. METHODS: A literature search was performed in the PubMed, EMBASE (Ovid), Cochrane Library (CENTRAL), China National Knowledge Infrastructure (CNKI), Weipu (VIP), and WanFang databases to identify original studies published from inception to August 20, 2021. Studies reporting the diagnostic performances of CEUS and CECT for differentiating MFP from PDAC were included. The meta-analysis was performed with Stata 15.0 software. The outcomes included the pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (-LR), diagnostic odds ratio (DOR), and summary receiver operating characteristic (SROC) curves of CEUS and CECT. Meta-regression was conducted to investigate heterogeneity. Bayesian network meta-analysis was conducted to indirectly compare the overall diagnostic performance. RESULTS: Twenty-six studies with 2115 pancreatic masses were included. The pooled sensitivity and specificity of CEUS for MFP were 82% (95% confidence interval [CI], 73%-88%; I2  = 0.00%) and 95% (95% CI, 90%-97%; I2  = 63.44%), respectively; the overall +LR, -LR, and DOR values were 15.12 (95% CI, 7.61-30.01), 0.19 (95% CI, 0.13-0.29), and 78.91 (95% CI, 30.94-201.27), respectively; and the area under the SROC curve (AUC) was 0.90 (95% CI, 0.87-92). However, the overall sensitivity and specificity of CECT were 81% (95% CI, 75-85%; I2  = 66.37%) and 94% (95% CI, 90-96%; I2  = 74.87%); the overall +LR, -LR, and DOR values were 12.91 (95% CI, 7.86-21.20), 0.21 (95% CI, 0.16-0.27), and 62.53 (95% CI, 34.45-113.51), respectively; and, the SROC AUC was 0.92 (95% CI, 0.90-0.94). The overall diagnostic accuracy of CEUS was comparable to that of CECT for the differential diagnosis of MFP and PDAC (relative DOR 1.26, 95% CI [0.42-3.83], P  > 0.05). CONCLUSIONS: CEUS and CECT have comparable diagnostic performance for differentiating MFP from PDAC, and should be considered as mutually complementary diagnostic tools for suspected focal pancreatic lesions.


Subject(s)
Carcinoma, Pancreatic Ductal , Pancreatic Neoplasms , Pancreatitis , Humans , Contrast Media , Bayes Theorem , Tomography, X-Ray Computed/methods , Pancreatic Neoplasms/diagnostic imaging , Carcinoma, Pancreatic Ductal/diagnostic imaging , Sensitivity and Specificity , Pancreatitis/diagnostic imaging , Ultrasonography/methods , Pancreatic Neoplasms
7.
World J Gastroenterol ; 28(21): 2350-2360, 2022 Jun 07.
Article in English | MEDLINE | ID: mdl-35800178

ABSTRACT

BACKGROUND: Contrast-enhanced ultrasound (CEUS) can be used to diagnose focal liver lesions (FLLs) in children. The America College of Radiology developed the CEUS liver imaging reporting and data system (LI-RADS) for standardizing CEUS diagnosis of FLLs in adult patients. Until now, no similar consensus or guidelines have existed for pediatric patients to improve imaging interpretation as adults. AIM: To evaluate the performance of CEUS LI-RADS combined with alpha-fetoprotein (AFP) in differentiating benign and malignant FLLs in pediatric patients. METHODS: Between January 2011 and January 2021, patients ≤ 18 years old who underwent CEUS for FLLs were retrospectively evaluated. The following criteria for diagnosing malignancy were proposed: Criterion I considered LR-4, LR-5, or LR-M lesions as malignancies; criterion II regarded LR-4, LR-5 or LR-M lesions with simultaneously elevated AFP (≥ 20 ng/mL) as malignancies; criterion III took LR-4 Lesions with elevated AFP or LR-5 or LR-M lesions as malignancies. The sensitivity, specificity, accuracy and area under the receiver operating characteristic curve (AUC) were calculated to determine the diagnostic value of the aforementioned criteria. RESULTS: The study included 63 nodules in 60 patients (mean age, 11.0 ± 5.2 years; 26 male). There were no statistically significant differences between the specificity, accuracy, or AUC of criterion II and criterion III (95.1% vs 80.5%, 84.1% vs 87.3%, and 0.794 vs 0.902; all P > 0.017). Notably, criterion III showed a higher diagnostic sensitivity than criterion II (100% vs 63.6%; P < 0.017). However, both the specificity and accuracy of criterion I was inferior to those of criterion II and criterion III (all P < 0.017). For pediatric patients more than 5 years old, the performance of the three criteria was overall similar when patients were subcategorized by age when compared to all patients in aggregate. CONCLUSION: CEUS LI-RADS combined with AFP may be a powerful diagnostic tool in pediatric patients. LR-4 with elevated AFP, LR-5 or LR-M lesions is highly suggestive of malignant tumors.


Subject(s)
Carcinoma, Hepatocellular , Digestive System Diseases , Liver Neoplasms , Adolescent , Adult , Carcinoma, Hepatocellular/pathology , Child , Child, Preschool , Contrast Media , Humans , Liver Neoplasms/pathology , Magnetic Resonance Imaging/methods , Male , Retrospective Studies , Sensitivity and Specificity , alpha-Fetoproteins
8.
Scand J Gastroenterol ; 57(5): 545-557, 2022 05.
Article in English | MEDLINE | ID: mdl-35049405

ABSTRACT

BACKGROUND: Endoscopic ultrasound-guided liver biopsy (EUS-LB) is an evolving technique. In this meta-analysis, we aimed to evaluate the value of EUS-LB for parenchymal and focal liver lesions. Besides, we aimed to assess the influences of needle-related factors on the performance of EUS-LB. Additionally, we aimed to assess the influence of various criteria on specimen adequacy. METHODS: We searched the PubMed, Embase, Cochrane Library databases up to 10 October 2021. The primary outcome was diagnostic yield, specimen adequacy, qualified specimens evaluated by rapid on-site evaluation (ROSE). The secondary outcome was adverse events. Subgroup analyses were based on needle type, needle size, fine-needle biopsy (FNB) needle type. A sensitivity analysis was conducted on specimen adequacy based on two definition criteria. RESULTS: In total, 33 studies were included. Pooled rates of diagnostic yield, specimen adequacy, qualified specimen by ROSE, adverse events were 95%, 84%, 93%, 3%. Subgroup analyses showed that Acquire needles generated higher diagnostic yield than SharkCore needles (99% vs. 88%, p = .047). Additionally, FNB needles demonstrated a higher rate of adverse events than FNA needles (6% vs. 1%, p = .028). Sensitivity analysis on specimen adequacy based on various criteria demonstrated that the specimen adequacy rate defined by the AASLD criterion was lower than that of the commonly-used criterion (37% vs. 84%, p = .001). CONCLUSION: EUS-LB is effective and safe for liver biopsy. Acquire needles provide better specimens than SharkCore needles. FNB needles may increase the risk of adverse events compared with FNA needles. The AASLD criterion is harder to achieve than the commonly-used criterion.


Subject(s)
Endoscopic Ultrasound-Guided Fine Needle Aspiration , Liver , Endoscopic Ultrasound-Guided Fine Needle Aspiration/adverse effects , Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods , Endosonography/methods , Humans , Liver/diagnostic imaging , Liver/pathology , Ultrasonography
9.
ACS Nano ; 13(9): 10036-10048, 2019 Sep 24.
Article in English | MEDLINE | ID: mdl-31373793

ABSTRACT

Rhenium diboride is an established superhard compound that can scratch diamond and can be readily synthesized under ambient pressure. Here, we demonstrate two synergistic ways to further enhance the already high yield strength of ReB2. The first approach builds on previous reports where tungsten is doped into ReB2 at concentrations up to 48 at. %, forming a rhenium/tungsten diboride solid solution (Re0.52W0.48B2). In the second approach, the composition of both materials is maintained, but the particle size is reduced to the nanoscale (40-150 nm). Bulk samples were synthesized by arc melting above 2500 °C, and salt flux growth at ∼850 °C was used to create nanoscale materials. In situ radial X-ray diffraction was then performed under high pressures up to ∼60 GPa in a diamond anvil cell to study mechanical properties including bulk modulus, lattice strain, and strength anisotropy. The differential stress for both Re0.52W0.48B2 and nano ReB2 (n-ReB2) was increased compared to bulk ReB2. In addition, the lattice-preferred orientation of n-ReB2 was experimentally measured. Under non-hydrostatic compression, n-ReB2 exhibits texture characterized by a maximum along the [001] direction, confirming that plastic deformation is primarily controlled by the basal slip system. At higher pressures, a range of other slip systems become active. Finally, both size and solid-solution effects were combined in nanoscale Re0.52W0.48B2. This material showed the highest differential stress and bulk modulus, combined with suppression of the new slip planes that opened at high pressure in n-ReB2.

10.
Nat Commun ; 9(1): 2725, 2018 07 13.
Article in English | MEDLINE | ID: mdl-30006515

ABSTRACT

Achieving a desirable combination of solid-like properties and fast self-healing is a great challenge due to slow diffusion dynamics. In this work, we describe a design concept that utilizes weak but abundant coordination bonds to achieve this objective. The designed PDMS polymer, crosslinked by abundant Zn(II)-carboxylate interactions, is very strong and rigid at room temperature. As the coordination equilibrium is sensitive to temperature, the mechanical strength of this polymer rapidly and reversibly changes upon heating or cooling. The soft-rigid switching ability σ, defined as G'max /G'min, can reach 8000 when ΔT = 100 °C. Based on these features, this polymer not only exhibits fast thermal-healing properties, but is also advantageous for various applications such as in orthopedic immobilization, conductive composites/adhesives, and 3D printing.

11.
Inorg Chem ; 57(6): 3232-3242, 2018 Mar 19.
Article in English | MEDLINE | ID: mdl-29481073

ABSTRACT

Coordination bonds are effective for constructing highly efficient self-healing materials as their strength is highly tunable. To design self-healing polymers with better performance, it is important to get a profound understanding of the structure-property relationships. However, this is challenging for self-healing polymers based on coordination bonds, because many parameters, such as bond energy, bond dynamics, and coordination number will have an essential effect on the mechanical and self-healing properties of the polymer. In this work, we synthesized two poly(dimethylsiloxane) (PDMS) polymers cross-linked by different Zn(II)-diiminopyridine coordination complexes (denoted as PDMS-NNN-Zn, PDMS-MeNNN-Zn respectively). The two cross-linking Zn(II)-diiminopyridine complexes are similar in coordination modes, but differ in coordination dynamics. As manifested by ITC, rheology, and tensile experiments, we confirm that the coordination bond in PDMS-MeNNN-Zn polymer films is weaker but more dynamic. Consequently, the PDMS-MeNNN-Zn polymer has poorer mechanical strength but higher stretchability and better self-healing properties. The inflicted cracks on PDMS-MeNNN-Zn polymer films can be completely healed after healing at room temperature for only 30 min with healing efficiencies higher than 90%. Such fast self-healing properties have never been achieved in self-healing polymers based on coordination bonds. Our results also demonstrate the important impact of the thermodynamic stability and kinetic lability of coordination complexes on the mechanical and self-healing properties of polymers. Such a comprehensive understanding is helpful for further design of novel synthetic polymers, which can achieve an optimal balance between the mechanical strength and self-healing performance.

SELECTION OF CITATIONS
SEARCH DETAIL
...