Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Microdevices ; 22(3): 43, 2020 06 06.
Article in English | MEDLINE | ID: mdl-32504225

ABSTRACT

This paper presents a fabrication method for glassy carbon neural electrode arrays that combines 3D printing and chemical pyrolysis technology. The carbon electrodes have excellent biological compatibility and can be used in neural signal recording. A pretreated Si wafer is used as the substrate for 3D printing, and then, stereolithography 3D printing technology is employed to print photosensitive resin into a cone shape. Next, chemical pyrolysis is applied to convert the 3D prints into glassy carbon electrodes and modify the electrochemical performance of the carbon electrodes. Finally, the glassy carbon electrodes are packed with conductive wires and PDMS. The proposed fabrication method simplifies the manufacturing process of carbon materials, and electrodes can be fabricated without the need of deep reactive ion etching (DRIE). The height of the carbon electrodes is 1.5 mm, and the exposure area of the tips is 0.78 mm2, which is convenient for the implantation procedure. The specific capacitance of the glassy carbon arrays is higher than that of a platinum electrode (9.18 mF/cm2 vs 3.32 mF/cm2, respectively), and the impedance at 1 kHz is lower (7.1 kΩ vs 8.8 kΩ). The carbon electrodes were tested in vivo, and they showed excellent performance in neural signal recording. The signal-to-noise ratio of the carbon electrodes is 50.73 ± 6.11, which is higher than that of the Pt electrode (20.15 ± 5.32) under the same testing conditions. The proposed fabrication method of glassy carbon electrodes provides a novel approach to manufacture penetrating electrodes for nerve interfaces in biomedical engineering and microelectromechanical systems.


Subject(s)
Brain-Computer Interfaces , Carbon/chemistry , Electrodes, Implanted , Glass/chemistry , Dimethylpolysiloxanes , Electric Conductivity , Equipment Design , Neurons/cytology , Nylons , Printing, Three-Dimensional , Signal-To-Noise Ratio , Silicon/chemistry
2.
Biomed Microdevices ; 20(1): 21, 2018 02 19.
Article in English | MEDLINE | ID: mdl-29460230

ABSTRACT

The cuff electrode provides a stable interface with peripheral nerves, which has been widely used in basic research and clinical practice. Currently, the cuff electrodes are limited by the planar processing of microfabrication. This paper presents a novel cuff electrode using high-aspect ratio carbon nanotubes (CNTs) integrated on a flexible biocompatible parylene. The microfabrication process unites the high quality vertical CNTs grown at high temperature with the heat sensitive parylene substrate in a highly controllable manner. The fabricated cuff electrodes have been utilized for extracellular nerve stimulation in rats. The experimental results demonstrate the proposed CNT electrode has a better performance than Pt electrode in nerve stimulation. Moreover, the effect of electrode position and stimulation frequency is demonstrated in this paper. This preliminary data indicates that flexible 3D CNTs cuff electrode provides an excellent platform for functional electrical stimulation.


Subject(s)
Electric Stimulation/instrumentation , Electric Stimulation/methods , Electrodes , Nanotubes, Carbon , Peripheral Nerves , Animals , Biocompatible Materials , Electrophysiology/methods , Equipment Design , Male , Microtechnology , Polymers , Rats, Sprague-Dawley , Sciatic Nerve/physiology , Temperature , Xylenes
3.
Theor Appl Genet ; 113(4): 619-29, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16770601

ABSTRACT

SIL040, an introgression line (IL) developed by introgressing chromosomal segments from an accession of Oryza rufipogon into an indica cultivar Guichao 2, showed significantly less grains per panicle than the recurrent parent Guichao 2. Quantitative trait locus (QTL) analysis in F2 and F3 generations derived from the cross between SIL040 and Guichao 2 revealed that gpa7, a QTL located on the short arm of chromosome 7, was responsible of this variation. Alleles from O. rufipogon decreased grains per panicle. To fine mapping of gpa7, a high-resolution map with 1,966 F2 plants derived from the cross between SIL040 and Guichao 2 using markers flanking gpa7 was constructed, and detailed quantitative evaluation of the structure of main panicle of each of F3 families derived from recombinants screened was performed. By two-step substitution mapping, gpa7 was finally narrowed down to a 35-kb region that contains five predicted genes in cultivated rice. The fact that QTLs for five panicle traits (length of panicle, primary branches per panicle, secondary branches per panicle, grains on primary branches and grains on secondary branches) were all mapped in the same interval as that for gpa7 suggested that this locus was associated with panicle structure, showing pleiotropic effects. The characterizing of panicle structure of IL SIL040 further revealed that, during the domestication from common wild allele to cultivated rice one at gpa7, not only the number of branches and grains per panicle increased significantly, more importantly, but also the ratio of secondary branches per panicle to total branches per panicle and the ratio of grains on secondary branches per panicle to total grains per panicle increased significantly. All these results reinforced the idea that gpa7 might play an important role in the regulation of grain number per panicle and the ratio of secondary branches per panicle during the domestication of rice panicle.


Subject(s)
Oryza/genetics , Quantitative Trait Loci , Alleles , Breeding , Chromosome Mapping , Chromosomes, Plant , Flowering Tops/anatomy & histology , Flowering Tops/genetics , Flowering Tops/growth & development , Genes, Plant , Genetic Markers , Oryza/anatomy & histology , Oryza/growth & development , Phenotype , Polymorphism, Genetic
SELECTION OF CITATIONS
SEARCH DETAIL
...