Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
1.
Med Sci Monit ; 30: e945471, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38864115

ABSTRACT

The Editors of Medical Science Monitor wish to inform you that the above manuscript has been retracted from publication due to concerns with the credibility and originality of the study, the manuscript content, and the Figure images. Reference: Rongfeng Zhang, Jianwei Liu, Shengpeng Yu, Dong Sun, Xiaohua Wang, Jingshu Fu, Jie Shen, Zhao Xie. Osteoprotegerin (OPG) Promotes Recruitment of Endothelial Progenitor Cells (EPCs) via CXCR4 Signaling Pathway to Improve Bone Defect Repair. Med Sci Monit, 2019; 25: 5572-5579. DOI: 10.12659/MSM.916838.


Subject(s)
Endothelial Progenitor Cells , Osteoprotegerin , Receptors, CXCR4 , Signal Transduction , Endothelial Progenitor Cells/metabolism , Receptors, CXCR4/metabolism , Osteoprotegerin/metabolism , Animals , Bone Regeneration/drug effects , Humans , Bone and Bones/metabolism , Osteogenesis/drug effects , Male , Mice , Wound Healing/drug effects
2.
Spectrochim Acta A Mol Biomol Spectrosc ; 319: 124527, 2024 Oct 15.
Article in English | MEDLINE | ID: mdl-38815313

ABSTRACT

Viscosity is a parameter used to measure the fluidity of liquids and a key indicator in evaluating the states of body fluid in biological tissues and lesions. Most traditional detection methods have many drawbacks such as a short emission wavelength and interference by background fluorescence. Inspired by the multiple double bond structure of retinal, a novel pH and viscosity dual-response fluorescent probe (Rh-TR) was constructed in this study. Rh-TR exhibited two emission signals centered at 510 and 660 nm. As the pH of the phosphate-buffered saline increased, the fluorescence at 510 nm increased by about 124-fold, while the change in fluorescence at 660 nm was not obvious. When detecting the change in viscosity using the probe, the fluorescence at 510 nm decreased by about 85 %, while the fluorescence at 660 nm increased by over 20-fold. The probe also showed high selectivity and little toxicity. As demonstrated by the biological imaging experiment, the probe successfully imaged changes in the pH and viscosity of cells and in a live animal model of zebrafish. Considering the unique structure of Rh-TR with retinal and its pH- and viscosity-switchable spectral property, the probe may find further application in detecting viscosity-related diseases and industrial detection.


Subject(s)
Fluorescent Dyes , Zebrafish , Fluorescent Dyes/chemistry , Fluorescent Dyes/chemical synthesis , Hydrogen-Ion Concentration , Viscosity , Animals , Humans , Spectrometry, Fluorescence , Optical Imaging
3.
Appl Opt ; 63(6): A24-A31, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38437354

ABSTRACT

Rapid testing of cement raw meal plays a crucial role in the cement production process, so there is an urgent need for a fast and accurate testing method. In this paper, a method based on the Savitzky-Golay (SG) smoothing and sample set partitioning based on joint x-y distance (SPXY) spectral data pre-processing is proposed to improve the accuracy of the laser-induced breakdown spectroscopy (LIBS) technique for quantitative analysis of cement raw meal components. Firstly, the spectral data is denoised by SG smoothing, which effectively reduces the noise and baseline variations in the spectra. Then, the denoised data is divided into sample sets by combining the SPXY sample division method, which improves the efficiency of data analysis. Finally, the delineated data set is modeled for quantitative analysis by a back-propagation (BP) neural network. Compared to the modeling effect of the four oxide contents of CaO, S i O 2, A l 2 O 3, and F e 2 O 3 in the Hold-Out method, the correlation coefficient (R) was improved by 26%, 10%, 17%, and 4%, respectively. The root mean square error (RMSE) was reduced by 47%, 33%, 43%, and 21%, respectively. The mean absolute percentage error (MAPE) was reduced by 63%, 60%, 36%, and 51%, respectively. The results show that there is a significant improvement in the model effect, which can effectively improve the accuracy of quantitative analysis of cement raw meal composition by LIBS. This is of great significance for the real-time detection of cement raw meal composition analysis.

4.
Article in English | MEDLINE | ID: mdl-37676586

ABSTRACT

OBJECTIVE: To evaluate whether the effect of radiofrequency ablation can be improved by using sacubitril/valsartan (S/V) to control blood pressure in hypertensive patients with persistent atrial fibrillation. METHODS: A total of 63 and 67 hypertension patients with persistent atrial fibrillation were enrolled in an S/V group and ACEI/ARB group, respectively. All patients underwent radiofrequency catheter ablation (RFCA). The blood pressure of the two groups was controlled within the range of 100-140 mmHg (high pressure) and 60-90 mmHg (low pressure). The clinical outcomes of the two groups were observed after 12 months of follow-up. RESULTS: No significant differences in blood pressure were observed between the S/V and ACEI/ARB groups. In addition, the recurrence rate of atrial fibrillation between the two groups was not different. The left atrial diameter was an independent predictor of recurrence (HR = 1.063, P = 0.008). However, in the heart failure subgroup, the recurrence rate of S/V was significantly lower than that of the ACEI/ARB group (P = 0.005), and Cox regression analysis showed that the recurrence risk of atrial fibrillation of the S/V group was 0.302 lower than that of the ACEI/ARB group. NT-proBNP, LVEF, and LAD were significantly improved in hypertension patients with heart failure when comparing cases before and at the end of follow-up. CONCLUSIONS: S/V is better than ACEI/ARB in reducing the recurrence of persistent atrial fibrillation in patients with hypertension and heart failure after RFCA.

5.
Pacing Clin Electrophysiol ; 46(8): 986-993, 2023 08.
Article in English | MEDLINE | ID: mdl-37334721

ABSTRACT

BACKGROUND: The use of contact force (CF) sensing catheters has provided a revolutionary improvement in catheter ablation (CA) of atrial fibrillation (AF) in the past decade. However, the success rate of CA for AF remains limited, and some complications still occur. METHODS: The TRUEFORCE trial (Catheter Ablation of Atrial Fibrillation using FireMagic TrueForce Ablation Catheter) is a multicenter, prospective, single-arm objective performance criteria study of AF patients who underwent their first CA procedure using FireMagic TrueForce ablation catheter. RESULTS: A total of 120 patients (118 with paroxysmal AF) were included in this study, and 112 patients included in the per-protocol analysis. Pulmonary vein isolation (PVI) was achieved in 100% of the patients, with procedure and fluoroscopy time of 146.63 ± 40.51 min and 12.89 ± 5.59 min, respectively. Freedom from recurrent atrial arrhythmia after ablation was present 81.25% (95% confidence interval [CI]: 72.78%-88.00%) of patients. No severe adverse events (death, stroke/transient ischemic attack [TIA], esophageal fistula, myocardial infarction, thromboembolism, or pulmonary vein stenosis) were detected during the follow-up. Four (4/115, 3.33%) adverse events were documented, including one abdominal discomfort, one femoral artery hematoma, one coughing up blood, and one postoperative palpitation and insomnia. CONCLUSIONS: This study demonstrated the clinical feasibility of FireMagic force-sensing ablation catheter in CA of AF, with a satisfactory short- and long-term efficacy and safety.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Prospective Studies , Treatment Outcome , Catheters , Pulmonary Veins/surgery , Catheter Ablation/methods , Recurrence
6.
Front Cardiovasc Med ; 10: 1105342, 2023.
Article in English | MEDLINE | ID: mdl-37273877

ABSTRACT

Background: The relationship between cumulative non-high-density lipoprotein cholesterol (non-HDL-C) burden and atherosclerotic cardiovascular disease (ASCVD) remains unclear. Objective: To prospectively examine the association between cumulative non-HDL-C burden and ASCVD risk in the Kailuan cohort of China. Methods: A total of 49,679 subjects who were free of ASCVD participated in three consecutive examinations in 2006, 2008 and 2010 were enrolled. Duration and concentration of cumulative exposure to non-HDL-C (cumNon-HDL-C) were respectively used to estimate the extent of cumulative non-HDL-C burden. The participants were divided into four groups according to durations of cumNon-HDL-C (0, 2, 4 and 6 years) and five groups according to the quintiles of cumNon-HDL-C concentration (<10.93, 10.93-12.68, 12.69-14.32, 14.33-16.72 and ≥16.73 mmol/L). Cox regression models were used to analyze the influence of cumulative non-HDL-C burden on ASCVD risk. Results: We identified 1,134 incident ASCVD cases during a mean of 4.89 years of follow-up. Multivariable adjusted analysis revealed that compared with no exposure, cumNon-HDL-C duration 2, 4 and 6 years increased ASCVD risk by 26% (HR: 1.26, 95% CI: 1.07-1.47), 56% (HR: 1.56, 95% CI: 1.31-1.86) and 91% (HR: 1.91, 95% CI: 1.59-2.31) respectively; The hazard ratios (HRs) for the fourth and fifth versus lowest quintile of cumNon-HDL-C concentration were 1.25 and 1.72 for ASCVD. Each standard deviation increment in cumNon-HDL-C concentration was associated with a 10% increased risk of ASCVD. Conclusion: Long-term and higher cumNon-HDL-C were all significantly associated with an increased risk of ASCVD independent of single non-HDL-C level.

7.
Medicine (Baltimore) ; 101(34): e30277, 2022 Aug 26.
Article in English | MEDLINE | ID: mdl-36042677

ABSTRACT

RATIONALE: We reported a case with cardiomyopathy induced by frequent premature ventricular contractions (PVCs) and followed ventricular escape beats (VEBs). PVCs with VEBs in the compensatory pause which induced cardiomyopathy is rarely reported. Also, the case exhibited many characteristics of PVCs which were more likely to induce cardiomyopathy, like the location of origin, the longer coupling interval, and the QRS wave companied with the P wave. PATIENT CONCERNS: A 53-year-old man with left ventricular (LV) dysfunction presented with palpation, chest distress, and dyspnea for 3 years. Holter revealed a high burden of ventricular rhythm of PVCs and another wide QRS patterns (96,562 total beats with 87,330 wide QRS beats in 24 hours). The LV ejection fraction decreased to 34% and the left ventricle, right and left atria all dilated. DIAGNOSIS: He was diagnosed with PVC-induced cardiomyopathy. INTERVENTIONS: The patient experienced intracardiac electrophysiological examination which revealed frequent PVCs followed by VEBs in the compensatory pause. Activation mapping of the PVCS and ablation were performed. OUTCOMES: PVCs and VEBs disappeared after ablation. The LV ejection fraction increased to 46% at 2 days after the procedure. The diameters of the right and left atria were also significantly reduced. LESSONS: VEBs may occur during the compensatory pause of PVCs. PVCs with VEBs can lead to a high burden of ventricular rhythm and LV dysfunction. Ablation of the PVCs can also eliminate VEBs and improve the LV function.


Subject(s)
Cardiomyopathies , Catheter Ablation , Ventricular Dysfunction, Left , Ventricular Premature Complexes , Cardiomyopathies/diagnosis , Catheter Ablation/methods , Humans , Male , Middle Aged , Stroke Volume/physiology , Ventricular Function, Left/physiology , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/etiology , Ventricular Premature Complexes/surgery
8.
Cardiol Res Pract ; 2022: 3002391, 2022.
Article in English | MEDLINE | ID: mdl-35784946

ABSTRACT

The optimal catheter ablation (CA) strategy for patients with persistent atrial fibrillation (PeAF) and heart failure (HF) remains uncertain. Between 2016 and 2020, 118 consecutive patients with PeAF and HF who underwent the CA procedure in two centers were retrospectively evaluated and divided into the pulmonary vein isolation (PVI)-only and PVI + additional ablation groups. Transthoracic echocardiography (TTE) was performed at baseline, one month, and 12 months after the CA procedure. The HF symptoms and left ventricular ejection fraction (LVEF) improvements were analyzed. Fifty-six patients underwent PVI only, and 62 patients received PVI with additional ablation. Compared with the baseline, a significant improvement in the LVEF and left atrial diameter postablation was observed in all patients. No significant HF improvement was detected in the PVI + additional ablation group than in the PVI-only group (74.2% vs. 71.4%, P = 0.736), but the procedure and ablation time were significantly longer (137.4 ± 7.5 vs. 123.1 ± 11.5 min, P = 0.001). There was no significant difference in the change in TTE parameters and the number of rehospitalizations. For patients with PeAF and HF, CA appears to improve left ventricular function. Additional ablation does not improve outcomes and has a significantly longer procedure time. Trial registration number is as follows: ChiCTR2100053745 (Chinese Clinical Trial Registry; https://www.chictr.org.cn/index.aspx).

9.
BMC Cardiovasc Disord ; 22(1): 179, 2022 04 19.
Article in English | MEDLINE | ID: mdl-35439961

ABSTRACT

OBJECTIVE: Ablation index (AI) is an effective ablation quality marker. Impedance is also an important factor for lesion formation. The present study evaluated the influence of the baseline impedance in the effect of ablation for atrial fibrillation (AF) guided by AI. METHODS: This was a retrospective study. 101 patients with paroxysmal AF (PAF) were enrolled. All patients underwent radiofrequency ablation guided by the same AI strategy. The ablation strategy was pulmonary vein (PV) isolation with non-PV triggers ablation. The baseline impedance of the ablation points was recorded. The patients were followed up every 3 months or so. RESULTS: During a median follow-up of 12 (4-14) months, freedom from AF/atrial tachycardia recurrence were 82.2%. No difference existed in baseline characteristics between the success group and the recurrence group. The average baseline impedance was 124.3 ± 9.7 Ω. The baseline impedance of the ablation points in success group was lower compared to the recurrence group (122.9 ± 9.4 vs. 130.5 ± 8.8 Ω, P < 0.01). The ratio of impedance drop in the success group was higher than the recurrence group ([8.8 ± 1.4]% vs. [8.1 ± 1.2]%, P = 0.03). Multivariate analysis revealed that baseline impedance, PAF duration and AI were the independent predictors of AF recurrence. The cumulative free of recurrence rate of low-impedance group (≤ 124 Ω, n = 54) was higher than that of high-impedance group. CONCLUSION: Baseline impedance correlates with clinical outcome of radiofrequency ablation for PAF guided by AI. Higher impedance in the same AI strategy may result in an ineffective lesion which probably causes recurrence.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Electric Impedance , Humans , Pulmonary Veins/surgery , Recurrence , Retrospective Studies , Treatment Outcome
10.
J Interv Card Electrophysiol ; 63(2): 311-321, 2022 Mar.
Article in English | MEDLINE | ID: mdl-33856622

ABSTRACT

PURPOSE: Coronary sinus-related arrhythmias are common; however, it is difficult to perform radiofrequency (RF) ablation at these sites efficiently and safely. High-power, short-duration ablation (HPSD) is a proven alternative strategy for pulmonary vein isolation (PVI); whether it can be applied to ablation of the coronary sinus is unknown. The purpose of this preliminary study was to evaluate the feasibility and safety of HPSD ablation in the coronary sinus. METHODS: Firstly, we demonstrated 4 clinical cases of 3 types of arrhythmias who had unsuccessful ablation with standard power initially, but received successful ablations with HPSD. Secondly, RF ablation was performed in the coronary sinus ostium (CSO) and middle cardiac vein (MCV) of 4 in vitro swine hearts. Two protocols were compared: HPSD (45 W/5 S×5 rounds) and a conventional strategy that used low-power, long-duration ablation (LPLD: 25 W/10 S ×5 rounds). The total duration of HPSD protocol was 25 s, and which of LPLD was 50 s. RESULTS: A total of 28 lesions were created. HPSD can produce longer, wider, deeper, and larger lesions than LPLD. This difference was more pronounced when the ablation was in the MCV. One instance of steam pop occurred during LPLD in the MCV. CONCLUSIONS: HPSD is an effective alternative strategy for ablation in coronary sinus according to clinical applications and preliminary animal study. However, the safety needs to be further evaluated based on more animal and clinical studies.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Coronary Sinus , Pulmonary Veins , Animals , Atrial Fibrillation/surgery , Catheter Ablation/methods , Coronary Sinus/surgery , Humans , Pulmonary Veins/surgery , Swine , Treatment Outcome
11.
Aging (Albany NY) ; 13(23): 25393-25407, 2021 12 12.
Article in English | MEDLINE | ID: mdl-34897030

ABSTRACT

OBJECTIVE: NINJ2 regulates activation of vascular endothelial cells, and genome-wide association studies showed that variants in NINJ2 confer risk to stroke. However, whether variants in NINJ2 are associated with coronary artery disease (CAD) is unknown. METHODS: We genotyped rs34166160 in NINJ2 in two independent Chinese GeneID populations which included 2,794 CAD cases and 4,131 controls, and performed genetics association studies. Functional studies were also performed to reveal the mechanisms. RESULTS: Allele rs34166160 significantly confers risk to CAD in the GeneID Hubei population which contained 1,440 CAD cases and 2,660 CAD-free controls (observed P-obs = 6.39 × 10-3 with an odds ratio (OR) was 3.39, adjusted P-adj = 8.12 × 10-3 with an OR of 3.10). The association was replicated in another population, GeneID Shandong population contained 1,354 CAD cases and 1,471 controls (P-obs = 3.33 × 10-3 with an OR of 3.14, P-adj = 0.01 with an OR of 2.74). After combining the two populations, the association was more significant (P-obs = 1.57 × 10-5 with an OR of 3.58, P-adj = 3.41 × 10-4 with an OR of 2.80). In addition, we found that rs34166160 was associated with the mRNA expression level of NINJ2 and the flanking region of rs34166160 can directly bind with transcriptional factor CCAAT-box/enhancer-binding protein beta, and the risk A allele has more transcription activity than non-risk C allele with or without LPS in HUVEC cells. CONCLUSIONS: Our study demonstrates that the functional rare variant rs34166160 in NINJ2 confers risk to CAD for the first time, and these findings further expand the range of the pathology of CAD and atherosclerosis.


Subject(s)
CCAAT-Enhancer-Binding Proteins/genetics , Cell Adhesion Molecules, Neuronal/genetics , Coronary Artery Disease/genetics , Genetic Predisposition to Disease/genetics , Alleles , Binding Sites/genetics , Case-Control Studies , Female , Genetic Association Studies , Humans , Male , Middle Aged , Polymorphism, Single Nucleotide/genetics , Real-Time Polymerase Chain Reaction , Risk Factors
12.
Front Cardiovasc Med ; 8: 674471, 2021.
Article in English | MEDLINE | ID: mdl-34169100

ABSTRACT

Background: Catheter ablation of atrial fibrillation is an alternative treatment for patients with tachycardia-bradycardia syndrome (TBS) to avoid pacemaker implantation. The risk stratification for atrial fibrillation and outcomes between ablation and pacing has not been fully evaluated. Methods: This retrospective study involved 306 TBS patients, including 141 patients who received catheter ablation (Ablation group, age: 62.2 ± 9.0 months, mean longest pauses: 5.2 ± 2.2 s) and 165 patients who received pacemaker implement (Pacing group, age: 62.3 ± 9.1 months, mean longest pauses: 6.0 ± 2.3 s). The primary endpoint was a composite of call cause mortality, cardiovascular-related hospitalization or thrombosis events (stroke, or peripheral thrombosis). The second endpoint was progress of atrial fibrillation and heart failure. Results: After a median follow-up of 75.4 months, the primary endpoint occurred in significantly higher patients in the pacing group than in the ablation group (59.4 vs.15.6%, OR 6.05, 95% CI: 3.73-9.80, P < 0.001). None of deaths was occurred in ablation group, and 1 death occurred due to cancer. Cardiovascular-related hospitalization occurred in 50.9% of the pacing group compared with 14.2% in the ablation group (OR: 4.87, 95% CI: 2.99-7.95, P < 0.001). More thrombosis events occurred in the pacing group than in the ablation group (12.7 vs. 2.1%, OR 6.06, 95% CI: 1.81-20.35, P = 0.004). Significant more patients progressed to persistent atrial fibrillation in pacing group than in ablation group (23.6 vs. 2.1%, P < 0.001). The NYHA classification of the pacing group was significantly higher than that of the ablation group (2.11 ± 0.83 vs. 1.50 ± 0.74, P < 0.001). The proportion of antiarrhythmic drugs and anticoagulants used in the pacing group was significantly higher than that in the ablation group (41.2 vs. 7.1%, P < 0.001; 16.4 vs. 2.1%, P = 0.009). Conclusion: Catheter ablation for patients with TBS was associated with a significantly lower rate of a composite end point of cardiovascular related hospitalization and thromboembolic events. Furthermore, catheter ablation reduced the progression of atrial fibrillation and heart failure.

13.
J Chromatogr A ; 1651: 462271, 2021 Aug 16.
Article in English | MEDLINE | ID: mdl-34102397

ABSTRACT

Successful applications of lipidomics in clinic need study large-scale samples, and the bottlenecks are in throughput and robustness of the lipid analytical method. Here, we report an untargeted lipidomics method by combining high throughput pretreatment in the 96-well plate with ultra-high performance liquid chromatography coupled to quadrupole time-of-flight tandem mass spectrometry. The developed method was validated to have satisfactory analytical characteristics in terms of linearity, repeatability and extraction recovery. It can be used to handle 96 samples simultaneously in 25 min and detect 441 lipids in plasma sample. Storage stability investigation on lipid extracts provided an operable procedure for large-scale sample analysis and demonstrated most lipids were stable in autosampler at 10 °C within 36 h and at -80 °C within 72 h after the pretreatment. To prove the usefulness, the method was employed to investigate abnormal plasma lipidome related to atrial fibrillation. A biomarker panel with the area under the curve (AUC) values of 0.831 and 0.745 was achieved in the discovery and external validation sets, respectively. These results showed that the developed method is applicable for large-scale biological sample handling and lipid analysis of plasma.


Subject(s)
Atrial Fibrillation/metabolism , Lipidomics/methods , Chromatography, High Pressure Liquid , Discriminant Analysis , Female , Humans , Least-Squares Analysis , Limit of Detection , Lipids/blood , Male , Middle Aged , Reproducibility of Results , Tandem Mass Spectrometry
14.
Pacing Clin Electrophysiol ; 44(7): 1193-1199, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34080696

ABSTRACT

OBJECTIVE: To investigate the efficacy and safety of His-bundle pacing (HBP) compared with the traditional biventricular pacing (BVP) on patients with brady-arrhythmias, who suffer from permanent atrial fibrillation (AF) and heart failure with reduced ejection fraction (HFrEF). METHODS: All patients with brady-arrhythmias, permanent AF and HFrEF were continuously enrolled from January 2017 to July 2019 and followed up for at least 12 months. The differences in QRS duration (QRSd), New York Heart Association (NYHA) classification, left ventricular ejection fraction (LVEF), tricuspid regurgitation grade, mitral regurgitation grade, left ventricular end-diastolic diameter (LVEDD), and left atrial size were compared. RESULTS: A total of 52 patients were enrolled: 37 patients were with HBP and 15 patients with BVP. There was no electrode dislodged, perforation, infection or thrombosis during the follow-up of 18.12 ± 4.45 months. The success rate for HBP implantation was 88.10%. The capture threshold of his-bundle and the threshold of the left ventricular lead remained stable during follow-up. LVEF increased to higher than 50% in 11 patients with HBP (29.73%). The NYHA classification (both p < .001), LVEF (both p < .001) and LVEDD improved significantly during the follow-up in both groups. NYHA (p = .030), LVEF (p = .013), and LVEDD (p = .003) improved in patients with HBP compared with BVP. CONCLUSION: HBP was safe and more effective in improving the cardiac function and remodeling in patients with brady-arrhythmias, permanent AF and HFrEF compared with BVP.


Subject(s)
Atrial Fibrillation/complications , Bradycardia/etiology , Bradycardia/therapy , Cardiac Resynchronization Therapy/methods , Heart Failure/complications , Aged , Aged, 80 and over , Atrial Fibrillation/physiopathology , Bundle of His/physiopathology , Cardiac Resynchronization Therapy/adverse effects , Female , Heart Failure/physiopathology , Humans , Male , Middle Aged , Stroke Volume , Treatment Outcome
15.
Int J Cardiol ; 335: 47-51, 2021 07 15.
Article in English | MEDLINE | ID: mdl-33845081

ABSTRACT

INTRODUCTION: The efficacy and safety of his-purkinje system pacing (HPSP) upgrades in patients with pacing-induced cardiomyopathy (PICM) and atrial fibrillation (AF) are still unknown. METHODS AND RESULTS: Patients with PICM were continuously enrolled from January 2018 to March 2020. All patients were further divided into AF subgroup and sinus rhythm subgroup. Clinical data including echocardiographic examination parameters, electrocardiogram (ECG) measurements, and New York Heart Association (NYHA) classification, were assessed before and after the procedure. The HPSP upgrades, including his bundle pacing (HBP) and left bundle branch pacing (LBBP) were completed in 34 of 36 (94%) patients, Complications including electrode dislodged, perforation, infection or thrombosis were not observed in the perioperative period. During a mean of 11.52 ± 5.40 months of follow-up. The left ventricular ejection fraction (LVEF) increased significantly (33.76 ± 7.54 vs 40.41 ± 9.06, P < 0.001), and the QRS duration decreased (184.22 ± 23.76 ms vs 120.52 ± 16.67 ms, P < 0.001) after the upgrades. LVEDD reversed from 59.29 ± 7.74 mm to 53.91 ± 5.92 mm (P < 0.001), and the NYHA functional class also improved to 2.00 ± 0.76 from 2.55 ± 0.91 at the first follow-up (P < 0.001). The left atrium (LA) size also slightly decreased compared to the initial state (47.44 ± 7.14 mm VS 45.56 ± 7.78, P = 0.010). BNP significantly decreased from a median value of 458.06(256.35-755.10) to 172.31(92.69-552.14) (P = 0.004). The threshold did not increase significantly (1.18 ± 0.76 mv@0.4 ms vs 1.26 ± 0.91mv @ 0.4 ms, P = 0.581). These improvements in patients with AF were similar with those in patients without AF (P > 0.05). CONCLUSIONS: HPSP upgrades improved the heart performance and reversed the left ventricular remodeling in patients suffering from PICM with or without AF, and it should be a promising choice in these patients.


Subject(s)
Atrial Fibrillation , Cardiomyopathies , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Bundle of His , Cardiac Pacing, Artificial , Humans , Stroke Volume , Ventricular Function, Left
16.
BMC Cardiovasc Disord ; 21(1): 214, 2021 04 27.
Article in English | MEDLINE | ID: mdl-33906609

ABSTRACT

BACKGROUND: To clarify the appropriate initial dosage of heparin during radiofrequency catheter ablation (RFCA) in patients with atrial fibrillation (AF) receiving uninterrupted nonvitamin K antagonist oral anticoagulant (NOAC) treatment. METHODS: A total of 187 consecutive AF patients who underwent their first RFCA in our center were included. In the warfarin group (WG), an initial heparin dose of 100 U/kg was administered (control group: n = 38). The patients who were on NOACs were randomly divided into 3 NOAC groups (NG: n = 149), NG110, NG120, and NG130, and were administered initial heparin doses of 110 U/kg, 120 U/kg, and 130 U/kg, respectively. During RFCA, the activated clotting time (ACT) was measured every 15 min, and the target ACT was maintained at 250-350 s by intermittent heparin infusion. The baseline ACT and ACTs at each 15-min interval, the average percentage of measurements at the target ACT, and the incidence of periprocedural bleeding and thromboembolic complications were recorded and analyzed. RESULTS: There was no significant difference in sex, age, weight, or baseline ACT among the four groups. The 15 min-ACT, 30 min-ACT, and 45 min-ACT were significantly longer in the WG than in NG110 and NG120. However, no significant difference in 60 min-ACT or 75 min-ACT was detected. The average percentages of measurements at the target ACT in NG120 (82.2 ± 23.6%) and NG130 (84.8 ± 23.7%) were remarkably higher than those in the WG (63.4 ± 36.2%, p = 0.007, 0.003, respectively). These differences were independent of the type of NOAC. The proportion of ACTs in 300-350 s in NG130 was higher than in WG (32.4 ± 31.8 vs. 34.7 ± 30.6, p = 0.735). Severe periprocedural thromboembolic and bleeding complications were not observed. CONCLUSIONS: For patients with AF receiving uninterrupted NOAC treatment who underwent RFCA, an initial heparin dosage of 120 U/kg or 130 U/kg can provide an adequate intraprocedural anticoagulant effect, and 130 U/kg allowed ACT to reach the target earlier. TRIAL REGISTRATION: Registration number: ChiCTR1800016491, First Registration Date: 04/06/2018 (Chinese Clinical Trial Registry http://www.chictr.org.cn/index.aspx ).


Subject(s)
Anticoagulants/administration & dosage , Atrial Fibrillation/surgery , Catheter Ablation , Dabigatran/administration & dosage , Heparin/administration & dosage , Rivaroxaban/administration & dosage , Stroke/prevention & control , Thromboembolism/prevention & control , Warfarin/administration & dosage , Administration, Oral , Aged , Anticoagulants/adverse effects , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Catheter Ablation/adverse effects , China , Dabigatran/adverse effects , Double-Blind Method , Drug Administration Schedule , Drug Monitoring , Female , Heparin/adverse effects , Humans , Male , Middle Aged , Postoperative Hemorrhage/chemically induced , Prospective Studies , Risk Assessment , Risk Factors , Rivaroxaban/adverse effects , Stroke/diagnosis , Stroke/etiology , Thromboembolism/diagnosis , Thromboembolism/etiology , Time Factors , Treatment Outcome , Warfarin/adverse effects , Whole Blood Coagulation Time
17.
Front Cardiovasc Med ; 8: 707996, 2021.
Article in English | MEDLINE | ID: mdl-35096987

ABSTRACT

Aims: Catheter ablation should be considered in patients with atrial fibrillation (AF) and with heart failure (HF) with reduced ejection fraction (EF; HFrEF) to improve survival and reduce heart failure hospitalization. Careful patient selection for AF ablation is key to achieving similar outcome benefits. However, limited data exist regarding predictors of recovered ejection fraction. We aimed to evaluate the predictors of recovered ejection fraction in consecutive patients with HF undergoing AF ablation. Methods and Results: A total of 156 patients [67.3% men, median age 63 (11)] with AF and HF underwent initial catheter ablation between September 2017 and October 2019 in the First Affiliated Hospital of Dalian Medical University. Overall, the percentage of recovered ejection fractions was 72.3%. Recovered EFs were associated with a 39% reduction in all-cause hospitalization compared to non-recovered EFs at the 1-year follow-up [23.8 vs. 62.8 (odds ratio) OR 2.09 (1.40-3.12), P < 0.001]. Univariate analysis for recovered EFs showed that diabetes (P = 0.083), prevalent HF (P = 0.014), prevalent AF (P = 0.051), LVEF (P = 0.022), and E/E' (P = 0.001) were associated with EF improvement. Multivariate analysis showed that the only independent predictor of EF recovery was E/E' [OR 1.13 (1.03-1.24); P = 0.011]. A receiver operating characteristic analysis determined that the suitable cut-off value for E/E' was 15 (sensitivity 38.7%, specificity 89.2%, the area under curve 0.704). Conclusions: Ejection fraction (EF) recovery occurred in 72.3% of patients, associated with a 39% reduction in all-cause hospitalization compared to the non-recovered EFs in our cohort. The only independent predictor of recovered EF was E/E' < 15 in our series.

18.
Pacing Clin Electrophysiol ; 43(10): 1165-1172, 2020 10.
Article in English | MEDLINE | ID: mdl-32896924

ABSTRACT

BACKGROUND: Atrioventricular node (AVN) ablation combined with His bundle pacing is an effective strategy for permanent atrial fibrillation (AF) with rapid ventricular rate refractory to pharmacological therapy. We aimed to access the feasibility and efficiency of His bundle pacing and AVN ablation guided by three-dimensional (3-D) mapping system throughout the procedure. METHODS: Eighteen patients with permanent AF with refractory rate and symptoms were referred for His bundle pacing and AVN ablation guided by 3-D mapping (CARTO3). Electroanatomic 3-D mapping of the right atrium and right ventricle was performed by the ablation catheter with CARTO 3 system, followed by the visualization of the leads for implantation and AVN ablation. RESULTS: Implantation of His bundle and ventricular leads and AVN ablation were achieved successfully with the help of 3-D mapping in 17 patients. Selective His bundle pacing was achieved in five patients (29.4%), and the other (70.6%) were nonselective His bundle pacing. The mean procedure duration was 99.4 ± 16.4 minutes. The mean fluoroscopy time was 7.0 ± 2.6 minutes. The time spent on His lead implantation was 6.1 ± 3.2 minutes. One patient experienced AVN ablation from left side under aortic valves due to no effect of ablation in right atrium. CONCLUSION: His bundle pacing and AVN ablation guided by throughout real-time 3-D mapping system are of high-efficiency and feasibility.


Subject(s)
Atrial Fibrillation/therapy , Atrioventricular Node/surgery , Bundle of His/physiopathology , Cardiac Pacing, Artificial/methods , Catheter Ablation/methods , Epicardial Mapping/methods , Aged , Combined Modality Therapy , Electrocardiography , Feasibility Studies , Female , Humans , Male
19.
Aging (Albany NY) ; 12(17): 16981-16998, 2020 Sep 09.
Article in English | MEDLINE | ID: mdl-32902410

ABSTRACT

OBJECTIVE: Genome-wide association studies (GWAS) and the candidate gene based association studies have identified a panel of variants associated with atrial fibrillation (AF), however, most of the identified single nucleotide polymorphisms (SNPs) were found located within intergenic or intronic genomic regions, and whether the positive SNPs have a real biological function is unknown, and the real disease causing gene need to be studied. RESULTS: The current results of the genetic studies including common variants identified by GWAS (338 index SNPs) and candidate gene based association studies (40 SNPs) were summarized. CONCLUSION: Our study suggests the relationship between genetic variants and possible targeted genes, and provides insight into potential genetic pathways underlying AF incidence and development. The results may provide an encyclopedia of AF susceptibility SNPs and shed light on the functional mechanisms of AF variants identified through genetic studies. METHODS: We summarized AF susceptibility SNPs identified by GWAS and candidate gene based association studies, and give a comprehensive functional annotation of all these AF susceptibility loci. by genomic annotation, microRNA binding prediction, promoter activity analysis, enhancer activity analysis, transcription factors binding activity prediction, expression quantitative trait loci (eQTL) analysis, long-range transcriptional regulatory function analysis, gene ontology and pathway enrichment analysis.

20.
Front Physiol ; 11: 617374, 2020.
Article in English | MEDLINE | ID: mdl-33584338

ABSTRACT

BACKGROUND: Electrocardiographic (ECG) characteristics of patients with isolated hypomagnesemia are not well defined. We aimed to investigate these ECG characteristics in order to define clearly the features of isolated hypomagnesemia. HYPOTHESIS: Lower serum magnesium could affect ECG parameters after excluding potential confounders. METHODS: This retrospective study was of patients with low serum magnesium <0.65 mmol/L compared with the same patients after restoration to normal serum magnesium. Patients with hypokalemia, hypocalcemia and other electrolyte disturbances were excluded. ECG parameters manually determined and analyzed were P wave dispersion, PR interval, QRS duration, ST-T changes, T wave amplitude, T peak-to-end interval (Tpe), corrected Tpe (Tpec), QT, corrected QT (QTc), QT peak corrected (QTpc) and Tpe dispersion, Tpe/QT ratio. RESULTS: Two-hundred-and-fourteen patients with isolated hypomagnesemia were identified with 50 of them (56.9 ± 13.6 years; 25 males) being eligible for final analysis from 270,997 patients presenting April 2011-October 2017. In the period of isolated hypomagnesemia, P wave duration was found prolonged (p ≤ 0.02); as was QTc (439 ± 27 vs. 433 ± 22, p = 0.01). Tpec (122 ± 24vs. 111 ± 22, p = 0.000) and Tpe/QT ratio (0.29 ± 0.05 vs. 0.27 ± 0.05, p = 0.000) were increased. QTpc decreased during hypomagnesemia (334 ± 28 vs. 342 ± 21, p = 0.02). However, no significant differences were found in PR interval, QRS duration (85 ± 12 ms vs. 86 ± 12 ms, p = 0.122) and ST-T segments between the patients and their own controls. CONCLUSIONS: In patients with isolated hypomagnesemia, P wave duration, QTc, Tpec, and Tpe/QT ratio suggesting atrial depolarization and ventricular repolarization dispersion were significantly increased compared with normal magnesium levels in the same patients after restoration to normal levels.

SELECTION OF CITATIONS
SEARCH DETAIL
...