Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
World J Clin Cases ; 12(19): 3854-3865, 2024 Jul 06.
Article in English | MEDLINE | ID: mdl-38994299

ABSTRACT

BACKGROUND: Cold-dampness-type knee osteoarthritis is a common middle-aged and elderly disease, but its pathogenesis is not fully understood, and its clinical treatment has limitations. Glucosamine sulfate capsules are commonly used for treating arthritis, and San Bi Tang is a classic formula of traditional Chinese medicine (TCM) that has the effects of warming yang, dispelling dampness, relaxing muscles, and activating collaterals. This research hypothesized that the combination of modified San Bi Tang and glucosamine sulfate capsules could enhance the clinical efficacy of treating cold-dampness-type knee osteoarthritis through complementary effects. AIM: To analyze the clinical efficacy of San Bi Tang combined with glucosamine sulfate capsules when treating cold-dampness-type knee osteoarthritis. METHODS: A total of 110 patients with cold-dampness-type knee osteoarthritis were selected as research subjects and randomly divided into a control group and an experimental group of 55 cases each. The control group received only treatment with glucosamine sulfate capsules, while the experimental group received additional treatment with modified San Bi Tang for a duration of 5 wk. The patients' knee joint functions, liver and kidney function indicators, adverse reactions, and vital signs were evaluated and analyzed using SPSS 26.0 software. RESULTS: Before treatment, the two groups' genders, ages, and scores were not significantly different, indicating comparability. Both groups' scores improved after treatment, which could indicate pain and knee joint function improvement, but the test group had better scores. The TCM-specific symptoms and the clinical efficacy of the treatment in the test group were higher. Before and after treatment, there were no abnormalities in the patients' liver and kidney function indicators. CONCLUSION: The combination of modified San Bi Tang and glucosamine sulfate capsules is superior to treatment with sulfated glucosamine alone and has high safety.

2.
Front Surg ; 9: 877040, 2022.
Article in English | MEDLINE | ID: mdl-35586506

ABSTRACT

Objective: To design and develop a disposable superfine catheter system for visual examination of bile and pancreatic ducts and predict its clinical application value. Methods: The superfine triple-lumen catheter and miniature photography technology were used to design and produce a disposable superfine catheter for visual examination of bile and pancreatic ducts, and animal experiments were conducted to compare said catheter and SpyGlass™. Results: The designed and developed disposable superfine catheter for visual examination of bile ducts with a diameter of 2.4 mm could enter the third-order and fourth-order bile ducts in the animal liver and also the gallbladder via the cystic duct for observation. The said catheter has a water injection rate of 0.8 mL/s, 0.16 megapixels, a resolution of 400 × 400, a depth of field of 0.3 to 20 mm, and a tilting up angle >90°. Conclusion: The new disposable catheter for visual examination of bile ducts has a superfine diameter, easier operation, and clearer imaging, and is expected to have a higher clinical practical value.

3.
Front Oncol ; 12: 1021625, 2022.
Article in English | MEDLINE | ID: mdl-36620563

ABSTRACT

Background: Early gastric cancer (EGC) has a high survival rate, but it is difficult to diagnosis. Recently, artificial intelligence (AI) based on deep convolutional neural network (DCNN) has made significant progress in the field of gastroenterology. The purpose of this study was to establish a DCNN assist system to improve the detection of EGC. Methods: 3400 EGC and 8600 benign images were collected to train the DCNN to detect EGC. Subsequently, its diagnostic ability was compared to that of endoscopists using an independent internal test set (ITS, including 1289 images) and an external test set (ETS, including 542 images) come from three digestive center. Results: The diagnostic time of DCNN and endoscopists were 0.028s, 8.05 ± 0.21s, 7.69 ± 0.25s in ITS, and 0.028s, 7.98 ± 0.19s, 7.50 ± 0.23s in ETS, respectively. In ITS, the diagnostic sensitivity and accuracy of DCNN are 88.08%(95% confidence interval,95%CI,85.24%-90.44%), 88.60% (95%CI,86.74%-90.22%), respectively. In ETS, the diagnostic sensitivity and accuracy are 92.08% (95%CI, 87.91%- 94.94%),92.07%(95%CI, 89.46%-94.08%),respectively. DCNN outperformed all endoscopists in ETS, and had a significantly higher sensitivity than the junior endoscopists(JE)(by18.54% (95%CI, 15.64%-21.84%) in ITS, also higher than JE (by21.67%,95%CI, 16.90%-27.32%) and senior endoscopists (SE) (by2.08%, 95%CI, 0.75%-4.92%)in ETS. The accuracy of DCNN model was higher (by10.47%,95%CI, 8.91%-12.27%) than that of JE in ITS, and also higher (by14.58%,95%CI, 11.84%-17.81%; by 1.94%,95%CI,1.25%-2.96%, respectively) than JE and SE in ETS. Conclusion: The DCNN can detected more EGC images in a shorter time than the endoscopists. It will become an effective tool to assist in the detection of EGC in the near future.

4.
Ultrasonics ; 51(3): 253-7, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21112601

ABSTRACT

An acoustic guidance method for pedicle screw placement during spine fixation surgery was recently investigated, with a view toward preventing complications such as injury to the spinal cord, thecal sac, and spinal nerve roots due to screw misplacement. The method relies upon the change in the ultrasound amplitude reflected at different sites-from the outer posterior cortex, through the pedicle, and towards the distal ventral cortex. The amplitude change was empirically observed through in vitro measurement of ultrasound amplitude at the different sites by inserting a 2.5-MHz single element transducer into a vertebral body through insertion pathway created by an advancing screw. This paper provides a theoretical and experimental rationale behind these empirical findings and distance-dependent correlation coefficients between amplitude and bone mineral density within the vertebral body, which approached 97%.


Subject(s)
Lumbar Vertebrae/diagnostic imaging , Ultrasonography, Interventional/methods , X-Ray Microtomography , Animals , Bone Density , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , In Vitro Techniques , Lumbar Vertebrae/surgery , Radiography, Interventional , Sheep, Domestic , Transducers
5.
Spine J ; 10(5): 422-32, 2010 May.
Article in English | MEDLINE | ID: mdl-20347399

ABSTRACT

BACKGROUND CONTEXT: In pedicle screw fixation surgery, rigid instruments are inserted into a vertebral body. When the instruments are misdirected within the pedicle or advanced too far beyond it, perforations of the inner or outer cortex can cause damage to the spinal nerve roots and spinal cord. These complications can occur despite the use of imaging modalities, such as radiographs, fluoroscopy, and computerized axial tomography (CAT) scans. A-Mode ultrasound (US), a nonionizing modality, merits study for its possible use in such a type of surgery. PURPOSE: The purpose of the study was to determine the utility of A-mode US during pedicle screw placement, to characterize the approach to the marrow-cortex interface, and to obtain the signature profiles of cortex perforations. STUDY DESIGN: A-Mode data were generated on insertion of a forward-viewing transducer (FVT) and a side-viewing transducer (SVT) to successively greater drilled depths along the insertion pathway. A-Mode broadband US backscatter (BUB) pedicle screw emulation experiments were conducted with transducers inserted into drilled sheep vertebral bodies. BUB amplitude patterns were observed and analyzed. Descriptive statistics were used. METHODS: In vitro acoustic experiments on vertebral bodies in a water bath were performed with two 1-MHz unfocused transducers to measure sound speed, broadband US attenuation, and backscatter coefficients. Micro-CAT scan three-dimensional (3-D) images of 10 disarticulated vertebral bodies were obtained pre- and postdrilling done in 5-mm depth increments with a flat-bottom drill. BUB patterns were noted of transducers inserted through rostral outer cortex, through the pedicle, and advanced to the ventral marrow-cortex interface. 2.5-MHz FVT and SVT were co-advanced in successive 5-mm increments along the insertion pathway, with BUBs measured at each point and the echoes composited into a single figure. Deliberate perforations of ventral cortex were made. RESULTS: Evident patterns or measures indicating the proximity of the ventral marrow-cortex interface were: 1) marrow BUB values increasing in amplitude over three distal peaks in most FVT cases (7 out of 10) and SVT cases (9 out of 10); 2) BUB ratio of marrow-cortex interface to the smallest marrow value greater than 2, in all FVT cases (10 out of 10) with FVT mean of 4.00+/-1.82 (2.25-8.33); and 3) a ratio of distal BUB value to starting cortex BUB in the 0. 82 to 1.62 range (mean, 0.98+/-0.30) in 80% of FVT cases. Ventral FVT perforations resulted in a major drop in the BUB value. CONCLUSIONS: The increase in the BUB amplitudes in the distal insertion pathway suggests that, at least with a 2.5-MHz transducer, an approximate 1.5-cm US window exists in most cases, by which close approach of the ventral marrow-cortex interface could be anticipated. Other ratios may serve as stop criteria to prevent further drilling. A precipitous drop in BUB amplitude may be an indication of a cortex perforation.


Subject(s)
Bone Screws , Lumbar Vertebrae/surgery , Ultrasonography, Interventional , Acoustics , Animals , In Vitro Techniques , Lumbar Vertebrae/diagnostic imaging , Sheep , Transducers , X-Ray Microtomography
6.
Appl Biochem Biotechnol ; 158(2): 398-407, 2009 Aug.
Article in English | MEDLINE | ID: mdl-18712288

ABSTRACT

A genetically engineered Escherichia coli was developed as the source of enzyme for rapidly quantifying glutamine. E. coli BL21 (DE3) cells overexpressing a glutamine synthetase from Bacillus subtilis were prepared as tube aliquots and used in a small volume of nontoxic mixture. The current method was compared to high performance liquid chromatography analysis, Sigma kit (GLN-1) and Mecke method. The method is applicable to a wide range of glutamine concentrations (0.05-2.5 mM) and correlates well to the detection results obtained from high performance liquid chromatography (Pearson correlation is 0.978 at the 0.01 level). Moreover, the whole assay procedure takes less than 15 min and uses nontoxic reagents, so it can be applied to monitor glutamine production and utilization conveniently.


Subject(s)
Escherichia coli/metabolism , Gene Expression Regulation, Enzymologic , Glutamate-Ammonia Ligase/metabolism , Glutamine/analysis , Glutamine/metabolism , Bacillus subtilis/enzymology , Bacillus subtilis/genetics , Chromatography, High Pressure Liquid , Escherichia coli/enzymology , Escherichia coli/genetics , Genetic Engineering , Glutamate-Ammonia Ligase/genetics
SELECTION OF CITATIONS
SEARCH DETAIL
...