Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Bioinformatics ; 24(1): 1, 2023 Jan 03.
Article in English | MEDLINE | ID: mdl-36597019

ABSTRACT

BACKGROUND: Prostate cancer is a major health concern in aging men. Paralleling an aging society, prostate cancer prevalence increases emphasizing the need for efficient diagnostic algorithms. METHODS: Retrospectively, 106 prostate tissue samples from 48 patients (mean age, [Formula: see text] years) were included in the study. Patients suffered from prostate cancer (n = 38) or benign prostatic hyperplasia (n = 10) and were treated with radical prostatectomy or Holmium laser enucleation of the prostate, respectively. We constructed tissue microarrays (TMAs) comprising representative malignant (n = 38) and benign (n = 68) tissue cores. TMAs were processed to histological slides, stained, digitized and assessed for the applicability of machine learning strategies and open-source tools in diagnosis of prostate cancer. We applied the software QuPath to extract features for shape, stain intensity, and texture of TMA cores for three stainings, H&E, ERG, and PIN-4. Three machine learning algorithms, neural network (NN), support vector machines (SVM), and random forest (RF), were trained and cross-validated with 100 Monte Carlo random splits into 70% training set and 30% test set. We determined AUC values for single color channels, with and without optimization of hyperparameters by exhaustive grid search. We applied recursive feature elimination to feature sets of multiple color transforms. RESULTS: Mean AUC was above 0.80. PIN-4 stainings yielded higher AUC than H&E and ERG. For PIN-4 with the color transform saturation, NN, RF, and SVM revealed AUC of [Formula: see text], [Formula: see text], and [Formula: see text], respectively. Optimization of hyperparameters improved the AUC only slightly by 0.01. For H&E, feature selection resulted in no increase of AUC but to an increase of 0.02-0.06 for ERG and PIN-4. CONCLUSIONS: Automated pipelines may be able to discriminate with high accuracy between malignant and benign tissue. We found PIN-4 staining best suited for classification. Further bioinformatic analysis of larger data sets would be crucial to evaluate the reliability of automated classification methods for clinical practice and to evaluate potential discrimination of aggressiveness of cancer to pave the way to automatic precision medicine.


Subject(s)
Prostate , Prostatic Neoplasms , Male , Humans , Retrospective Studies , Reproducibility of Results , Prostatic Neoplasms/pathology , Algorithms
2.
BMC Med Imaging ; 21(1): 123, 2021 08 12.
Article in English | MEDLINE | ID: mdl-34384385

ABSTRACT

BACKGROUND: To assess the potential of radiomic features to quantify components of blood in intraaortic vessels to non-invasively predict moderate-to-severe anemia in non-contrast enhanced CT scans. METHODS: One hundred patients (median age, 69 years; range, 19-94 years) who received CT scans of the thoracolumbar spine and blood-testing for hemoglobin and hematocrit levels ± 24 h between 08/2018 and 11/2019 were retrospectively included. Intraaortic blood was segmented using a spherical volume of interest of 1 cm diameter with consecutive radiomic analysis applying PyRadiomics software. Feature selection was performed applying analysis of correlation and collinearity. The final feature set was obtained to differentiate moderate-to-severe anemia. Random forest machine learning was applied and predictive performance was assessed. A decision-tree was obtained to propose a cut-off value of CT Hounsfield units (HU). RESULTS: High correlation with hemoglobin and hematocrit levels was shown for first-order radiomic features (p < 0.001 to p = 0.032). The top 3 features showed high correlation to hemoglobin values (p) and minimal collinearity (r) to the top ranked feature Median (p < 0.001), Energy (p = 0.002, r = 0.387), Minimum (p = 0.032, r = 0.437). Median (p < 0.001) and Minimum (p = 0.003) differed in moderate-to-severe anemia compared to non-anemic state. Median yielded superiority to the combination of Median and Minimum (p(AUC) = 0.015, p(precision) = 0.017, p(accuracy) = 0.612) in the predictive performance employing random forest analysis. A Median HU value ≤ 36.5 indicated moderate-to-severe anemia (accuracy = 0.90, precision = 0.80). CONCLUSIONS: First-order radiomic features correlate with hemoglobin levels and may be feasible for the prediction of moderate-to-severe anemia. High dimensional radiomic features did not aid augmenting the data in our exemplary use case of intraluminal blood component assessment. Trial registration Retrospectively registered.


Subject(s)
Anemia/diagnosis , Aorta/diagnostic imaging , Hematocrit , Hemoglobins/analysis , Image Interpretation, Computer-Assisted/methods , Machine Learning , Tomography, X-Ray Computed , Adult , Aged , Aged, 80 and over , Decision Trees , Female , Humans , Male , Middle Aged , Young Adult
3.
Sci Rep ; 11(1): 14248, 2021 07 09.
Article in English | MEDLINE | ID: mdl-34244594

ABSTRACT

Our purpose was to analyze the robustness and reproducibility of magnetic resonance imaging (MRI) radiomic features. We constructed a multi-object fruit phantom to perform MRI acquisition as scan-rescan using a 3 Tesla MRI scanner. We applied T2-weighted (T2w) half-Fourier acquisition single-shot turbo spin-echo (HASTE), T2w turbo spin-echo (TSE), T2w fluid-attenuated inversion recovery (FLAIR), T2 map and T1-weighted (T1w) TSE. Images were resampled to isotropic voxels. Fruits were segmented. The workflow was repeated by a second reader and the first reader after a pause of one month. We applied PyRadiomics to extract 107 radiomic features per fruit and sequence from seven feature classes. We calculated concordance correlation coefficients (CCC) and dynamic range (DR) to obtain measurements of feature robustness. Intraclass correlation coefficient (ICC) was calculated to assess intra- and inter-observer reproducibility. We calculated Gini scores to test the pairwise discriminative power specific for the features and MRI sequences. We depict Bland Altmann plots of features with top discriminative power (Mann-Whitney U test). Shape features were the most robust feature class. T2 map was the most robust imaging technique (robust features (rf), n = 84). HASTE sequence led to the least amount of rf (n = 20). Intra-observer ICC was excellent (≥ 0.75) for nearly all features (max-min; 99.1-97.2%). Deterioration of ICC values was seen in the inter-observer analyses (max-min; 88.7-81.1%). Complete robustness across all sequences was found for 8 features. Shape features and T2 map yielded the highest pairwise discriminative performance. Radiomics validity depends on the MRI sequence and feature class. T2 map seems to be the most promising imaging technique with the highest feature robustness, high intra-/inter-observer reproducibility and most promising discriminative power.

4.
Eur Radiol ; 30(12): 6757-6769, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32676784

ABSTRACT

OBJECTIVES: To analyze the performance of radiological assessment categories and quantitative computational analysis of apparent diffusion coefficient (ADC) maps using variant machine learning algorithms to differentiate clinically significant versus insignificant prostate cancer (PCa). METHODS: Retrospectively, 73 patients were included in the study. The patients (mean age, 66.3 ± 7.6 years) were examined with multiparametric MRI (mpMRI) prior to radical prostatectomy (n = 33) or targeted biopsy (n = 40). The index lesion was annotated in MRI ADC and the equivalent histologic slides according to the highest Gleason Grade Group (GrG). Volumes of interest (VOIs) were determined for each lesion and normal-appearing peripheral zone. VOIs were processed by radiomic analysis. For the classification of lesions according to their clinical significance (GrG ≥ 3), principal component (PC) analysis, univariate analysis (UA) with consecutive support vector machines, neural networks, and random forest analysis were performed. RESULTS: PC analysis discriminated between benign and malignant prostate tissue. PC evaluation yielded no stratification of PCa lesions according to their clinical significance, but UA revealed differences in clinical assessment categories and radiomic features. We trained three classification models with fifteen feature subsets. We identified a subset of shape features which improved the diagnostic accuracy of the clinical assessment categories (maximum increase in diagnostic accuracy ΔAUC = + 0.05, p < 0.001) while also identifying combinations of features and models which reduced overall accuracy. CONCLUSIONS: The impact of radiomic features to differentiate PCa lesions according to their clinical significance remains controversial. It depends on feature selection and the employed machine learning algorithms. It can result in improvement or reduction of diagnostic performance. KEY POINTS: • Quantitative imaging features differ between normal and malignant tissue of the peripheral zone in prostate cancer. • Radiomic feature analysis of clinical routine multiparametric MRI has the potential to improve the stratification of clinically significant versus insignificant prostate cancer lesions in the peripheral zone. • Certain combinations of standard multiparametric MRI reporting and assessment categories with feature subsets and machine learning algorithms reduced the diagnostic performance over standard clinical assessment categories alone.


Subject(s)
Diffusion Magnetic Resonance Imaging , Machine Learning , Multiparametric Magnetic Resonance Imaging , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery , Adult , Aged , Aged, 80 and over , Algorithms , Area Under Curve , Biopsy , Cluster Analysis , Humans , Male , Middle Aged , Principal Component Analysis , Prostate/diagnostic imaging , Prostatectomy , Reproducibility of Results , Retrospective Studies , Support Vector Machine , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...