Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Materials (Basel) ; 17(10)2024 May 10.
Article in English | MEDLINE | ID: mdl-38793328

ABSTRACT

High-entropy alloys are promising candidates expected to be applied in transportation equipment serving in extreme environments due to their excellent properties. CoCrFeMnNi high-entropy alloy is a typical representative of them, and its low temperature performance is excellent. In this study, to evaluate the feasibility of forming HEA shells, the deformation behavior of CoCrFeMnNi under a plane-stress state at lower temperatures was thoroughly studied. Firstly, a thin-walled HEA tube was fabricated using hot extrusion and further formed into a thin shell for uniaxial tensile and biaxial bulging tests. Subsequently, uniaxial tensile tests at cryogenic temperatures were conducted. Both the strength and the ductility improves as the temperature decreases from -160 °C to -196 °C. Then, a systematic low-temperature bulging test was performed using isothermal dome tests and the thickness uniformity analysis of the bulged specimens was carried out. In addition, grain microstructural observation using EBSD was characterized analyze the possible deformation mechanism at the cryogenic temperature under the biaxial stress state. This study, for the first time, investigated the biaxial deformation behavior of HEA. Considering the plane-stress state deformation is the dominant type in the thin-walled shell deformation, this study enables us to provide direct guidance for various sheet-forming processes of HEAs.

2.
Am J Gastroenterol ; 118(5): 802-811, 2023 05 01.
Article in English | MEDLINE | ID: mdl-36219172

ABSTRACT

INTRODUCTION: Although the 9-minute mean withdrawal time (m-WT) is often reported to be associated with the optimal adenoma detection rate (ADR), no randomized trials of screening colonoscopy have confirmed the impact of a 9-minute m-WT on adenoma miss rate (AMR) and ADR. METHODS: A multicenter tandem trial was conducted in 11 centers. Seven hundred thirty-three asymptomatic participants were randomized to receive segmental tandem screening colonoscopy with a 9-minute withdrawal, followed by a 6-minute withdrawal (9-minute-first group, 9MF, n = 366) or vice versa (6-minute-first group, 6MF, n = 367). The primary outcome was the lesion-level AMR. RESULTS: The intention-to-treat analysis revealed that 9MF significantly reduced the lesion-level (14.5% vs 36.6%, P < 0.001) and participant-level AMR (10.9% vs 25.9%, P < 0.001), advanced adenoma miss rate (AAMR, 5.3% vs 46.9%, P = 0.002), multiple adenomas miss rate (20.7% vs 56.5%, P = 0.01), and high-risk adenomas miss rate (14.6% vs 39.5%, P = 0.01) of 6MF without compromising detection efficiency ( P = 0.79). In addition, a lower false-negative rate for adenomas ( P = 0.002) and high-risk adenomas ( P < 0.05), and a lower rate of shortening surveillance schedule ( P < 0.001) were also found in 9MF, accompanying with an improved ADR in the 9-minute vs 6-minute m-WT (42.3% vs 33.5%, P = 0.02). The independent inverse association between m-WT and AMR remained significant even after adjusting ADR, and meanwhile, 9-minute m-WT was identified as an independent protector for AMR and AAMR. DISCUSSION: In addition to increasing ADR, 9-minute m-WT also significantly reduces the AMR and AAMR of screening colonoscopy without compromising detection efficiency.


Subject(s)
Adenoma , Colonoscopy , Humans , Adenoma/diagnosis
3.
J Hematol Oncol ; 15(1): 162, 2022 11 04.
Article in English | MEDLINE | ID: mdl-36333749

ABSTRACT

No fully validated risk-stratification strategies have been established in China where colonoscopies resources are limited. We aimed to develop and validate a fecal immunochemical test (FIT)-based risk-stratification model for colorectal neoplasia (CN); 10,164 individuals were recruited from 175 centers nationwide and were randomly allocated to the derivation (n = 6776) or validation cohort (n = 3388). Multivariate logistic analyses were performed to develop the National Colorectal Polyp Care (NCPC) score, which formed the risk-stratification model along with FIT. The NCPC score was developed from eight independent predicting factors and divided into three levels: low risk (LR 0-14), intermediate risk (IR 15-17), and high risk (HR 18-28). Individuals with IR or HR of NCPC score or FIT+ were classified as increased-risk individuals in the risk-stratification model and were recommended for colonoscopy. The IR/HR of NCPC score showed a higher prevalence of CNs (21.8%/32.8% vs. 11.0%, P < 0.001) and ACNs (4.3%/9.2% vs. 2.0%, P < 0.001) than LR, which was also confirmed in the validation cohort. Similar relative risks and predictive performances were demonstrated between non-specific gastrointestinal symptoms (NSGS) and asymptomatic cohort. The risk-stratification model identified 73.5% CN, 82.6% ACN, and 93.6% CRC when guiding 52.7% individuals to receive colonoscopy and identified 55.8% early-onset ACNs and 72.7% early-onset CRCs with only 25.6% young individuals receiving colonoscopy. The risk-stratification model showed a good risk-stratification ability for CN and early-onset CRCs in Chinese population, including individuals with NSGS and young age.


Subject(s)
Colorectal Neoplasms , Early Detection of Cancer , Humans , Colorectal Neoplasms/diagnosis , Colorectal Neoplasms/epidemiology , Prospective Studies , Risk Factors
4.
Clin Gastroenterol Hepatol ; 20(2): e168-e181, 2022 02.
Article in English | MEDLINE | ID: mdl-33220526

ABSTRACT

BACKGROUND & AIMS: Although current quality indicators of colonoscopy recommend 6 minutes as the minimum standard for withdrawal time (WT), the impact of a WT longer than 6 minutes on neoplasia detection is unclear. METHODS: A multicenter randomized controlled trial involving 1027 patients was conducted from January 2018 to July 2019. Participants were randomly divided into a 9-minute (n = 514) and 6-minute (n = 513) WT group, and a timer was used to adjust the withdrawal speed. The primary outcome was the adenoma detection rate (ADR). RESULTS: Intention-to-treat analysis showed a significantly higher ADR in the 9-minute versus 6-minute WT group (36.6% vs. 27.1%, P = .001). Prolonging WT from 6 to 9 minutes significantly increased ADR of the proximal colon (21.4% vs. 11.9%, P < .001) as well as of the less experienced colonoscopists (36.8% vs. 23.5%, P = .001). Improvements were also observed in the polyp detection rate (58.0% vs. 47.8%, P < .001), and mean number of polyps and adenomas detected per colonoscopy (1.1 vs. 0.9, P = .002; 0.5 vs. 0.4, P = .008, respectively). The higher ADRs in 9-minute WT were also confirmed by the per-protocol (PP) analysis and subgroup analyses, with an increased rate of sessile serrated lesion detection in the 9-minute WT by PP analysis (4.0% vs. 1.3%, P = .04). Multivariate logistic regression demonstrated that the 9-minute WT was independently associated with increased ADR (P = .005). CONCLUSIONS: Prolonging WT from 6 to 9 minutes significantly improved ADR, especially in the proximal colon and for less experienced colonoscopists. A 9-minute WT benchmark should be considered as one of the quality indicators of colonoscopy. ClinicalTrials.gov (identifier, NCT03399045).


Subject(s)
Adenoma , Colonic Polyps , Colorectal Neoplasms , Polyps , Adenoma/diagnosis , Colonic Polyps/diagnosis , Colonoscopy/methods , Colorectal Neoplasms/diagnosis , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...